Spring Optical Communication is one of the largest and best 40g qsfp+ sr4 transceiver module 850nm 150m mpo ddm multimode optical transceiver manufacturers and suppliers with rich experience. Welcome to buy our high quality products or wholesale our customized 40g qsfp+ sr4 transceiver module 850nm 150m mpo ddm multimode optical transceiver in stock with our factory. Also, free sample is also available if necessary.
The 40G QSFP+ SR4 Transceiver Module supports four 10.3125Gbps optical lanes using 850nm VCSEL transmitters. Designed for multimode fiber, it provides links up to 100m over OM3 and 150m over OM4. Featuring an MPO interface, digital diagnostic monitoring (DDM), and a -40C to +85C operating temperature range, it supports compatible 40GbE data center interconnections.
Product Overview

Spring Optical's 40G QSFP+ SR4 Transceiver Module is designed for 40Gbps-class parallel optical transmission over multimode fiber. The DQS4-8M40-SIY8 series uses four 850nm VCSEL-based transmitters operating at 10.3125Gbps per lane, with a specified maximum reach of 100m over OM3 and 150m over OM4 fiber.
The optical module features an MPO interface, a nominal 3.3V power supply, and digital diagnostic monitoring for temperature, supply voltage, transmitter bias current, TX optical power, and RX optical power. The specified operating case temperature range for this model is -40C to +85C.
The product lists QSFP+ MSA compliance, IEEE 802.3ba-2010 40GbE XLPPI electrical-interface compliance, and IEEE 802.3ae 10GBASE-SR optical-specification compliance. Typical applications include data center backbone links and compatible high-speed network interconnections.
Key Features & Engineering Advantages
40Gbps-Class Parallel Optical Transmission - Four 10.3125Gbps lanes support high-speed QSFP+ network connectivity.
850nm VCSEL Multimode Optics - Supports short-range parallel optical transmission using 850nm VCSEL-based transmitters.
100m OM3 / 150m OM4 Reach - Provides defined transmission distances for multimode fiber infrastructure.
MPO Optical Interface - Supports parallel-fiber connections for compatible 40G data center cabling.
Digital Diagnostic Monitoring (DDM) - Monitors module temperature, voltage, TX bias current, and TX/RX optical power.
Industrial Temperature Support - The DQS4-8M40-SIY8 model is specified for -40C to +85C operation.
Technical Specifications
General Specifications
| Parameter | Specification |
|---|---|
| Product Model | DQS4-8M40-SIY8 |
| Datasheet Version | V0.1 |
| Product Type | 40G QSFP+ SR4 Multimode Optical Transceiver |
| Ethernet Class | 40GbE |
| Parallel Optical Channels | 4 |
| Signaling Rate per Channel | 10.3125Gbps |
| Optical Architecture | 4 Parallel TX Lanes / 4 Parallel RX Lanes |
| Nominal Wavelength | 850nm |
| Transmitter | 850nm VCSEL-Based |
| Receiver Type | Not Specified in Source |
| Fiber Type | Multimode Fiber |
| Maximum OM3 Distance | 100m |
| Maximum OM4 Distance | 150m |
| Optical Connector | MPO |
| Form Factor | QSFP+ |
| Power Supply | 3.3V |
| Specified Power Consumption | 1.5W |
| Specified Supply Current | 450mA |
| Operating Case Temperature | -40C to +85C |
| Commercial Temperature Mentioned in Features | 0C to +70C |
| Digital Diagnostics | DDM |
| Electrical Interface | 40GbE XLPPI |
| Listed Compliance | QSFP+ MSA, IEEE 802.3ba-2010, IEEE 802.3ae 10GBASE-SR |
| Application | Data Center Backbone |
The ordering table identifies the industrial-temperature version. No separate commercial-temperature part number is provided in the source.
Absolute Maximum Ratings
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Storage Temperature | TS | -40 | - | 85 | C |
| Relative Humidity | HA | 0 | - | 85 | % |
Source Notes
Suitable for wave soldering.
Only for soldering by iron.
These soldering notes are reproduced from the original ratings section. Their applicability to the completed hot-pluggable QSFP+ module requires engineering confirmation.
Recommended Operating Conditions
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Case Temperature | TC | -40 | - | 85 | C |
| Power Supply Voltage | VCC | 3.135 | 3.3 | 3.465 | V |
| Signaling Rate per Channel | - | - | 10.3125 | - | Gbps |
Additional Operating Parameters
| Parameter | Symbol | Specified Value | Unit | Notes |
|---|---|---|---|---|
| Supply Noise Rejection | - | 100 | mV | Source specification |
| Receiver Differential Data Output | - | 100 | Ohm | Source specification |
| Operating Distance | D | 100 | m | OM3 MMF |
| Maximum OM4 Operating Distance | - | 150 | m | Product features |
Electrical Characteristics
Test Condition: T = 25C, unless otherwise noted.
| Parameter | Symbol | Specified Value | Unit |
|---|---|---|---|
| Power Consumption | - | 1.5 | W |
| Supply Current | Icc | 450 | mA |
The supplied text does not clearly identify whether these values are typical or maximum limits. They are therefore retained as specified values pending confirmation.
Transmitter Characteristics
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Signaling Rate per Lane | GBb | - | 10.3125 | - | GBb (source notation) |
| Center Wavelength | lambda | 840 | 850 | 860 | nm |
| RMS Spectral Width | SW | - | - | 0.6 | nm |
| Average Launch Power per Lane | Pf | -8.4 | - | +2.4 | dBm |
| Optical Modulation Amplitude per Lane | TxOMA | -6.4 | - | +3 | dBm |
| Average Launch Power of OFF Transmitter per Lane | - | - | - | -30 | dBm |
| Extinction Ratio | ER | 3 | - | - | dB |
Note: The per-lane signaling-rate unit appears as "GBb" in the source. The product description separately specifies 10.3125Gbps per optical lane.
Receiver Characteristics
The source labels this section "Electrical Interface Characteristics" but lists receiver optical performance parameters. The values are grouped here according to their engineering function.
| Parameter | Symbol | Specified Value | Unit | Notes |
|---|---|---|---|---|
| Signaling Rate per Lane | GBb | 10.3125 | GBb | Source notation |
| Operating Wavelength Range | lambda | 840 to 860 | nm | - |
| Damage Threshold | - | 3.4 | dBm | - |
| Average Receiver Input Power per Lane | - | -10.3 to +2.4 | dBm | - |
| Receive Power per Lane, OMA | - | 3 | dBm | Source limit position unclear |
| Receiver Sensitivity, OMA | SOMA | -11.1 | dBm | BER = 1E-12 |
| Receiver Reflectance | - | -12 | dB | - |
| LOS Assert | LOSA | -30 | dBm | - |
| LOS Deassert | LOSD | -11 | dBm | - |
| LOS Hysteresis | - | 0.5 | dB | - |
The specification does not unambiguously preserve all Min/Typ/Max positions for the receiver parameters. The values above are reported without assigning unsupported limit types.
Digital Diagnostic Monitoring Accuracy
| Parameter | Accuracy | Unit |
|---|---|---|
| Internally Measured Transceiver Temperature | +/-3 | C |
| Internally Measured Supply Voltage | +/-3 | % |
| Measured TX Bias Current | +/-10 | % |
| Measured TX Output Power | +/-3 | dB |
| Measured RX Average Optical Power | +/-3 | dB |
The module supports digital diagnostic monitoring of the listed operating parameters. Exact management-memory addresses and module compatibility requirements should be confirmed against the approved host-interface documentation.
QSFP+ Pin Assignment and Description
The module uses a 38-pin QSFP+ electrical interface.
| Pin | Logic | Symbol | Description |
|---|---|---|---|
| 1 | - | GND | Ground |
| 2 | CML-I | Tx2n | Transmitter Inverted Data Input |
| 3 | CML-I | Tx2p | Transmitter Non-Inverted Data Output* |
| 4 | - | GND | Ground |
| 5 | CML-I | Tx4n | Transmitter Inverted Data Input |
| 6 | CML-I | Tx4p | Transmitter Non-Inverted Data Output* |
| 7 | - | GND | Ground |
| 8 | LVTTL-I | ModSelL | Module Select |
| 9 | LVTTL-I | ResetL | Module Reset |
| 10 | - | VccRx | +3.3V Receiver Power Supply |
| 11 | LVCMOS-I/O | SCL | Two-Wire Serial Interface Clock |
| 12 | LVCMOS-I/O | SDA | Two-Wire Serial Interface Data |
| 13 | - | GND | Ground |
| 14 | CML-O | Rx3p | Receiver Non-Inverted Data Output |
| 15 | CML-O | Rx3n | Receiver Inverted Data Output |
| 16 | - | GND | Ground |
| 17 | CML-O | Rx1p | Receiver Non-Inverted Data Output |
| 18 | CML-O | Rx1n | Receiver Inverted Data Output |
| 19 | - | GND | Ground |
| 20 | - | GND | Ground |
| 21 | CML-O | Rx2n | Receiver Inverted Data Output |
| 22 | CML-O | Rx2p | Receiver Non-Inverted Data Output |
| 23 | - | GND | Ground |
| 24 | CML-O | Rx4n | Receiver Inverted Data Output |
| 25 | CML-O | Rx4p | Receiver Non-Inverted Data Output |
| 26 | - | GND | Ground |
| 27 | LVTTL-O | ModPrsL | Module Present |
| 28 | LVTTL-O | IntL | Interrupt |
| 29 | - | VccTx | +3.3V Transmitter Power Supply |
| 30 | - | Vcc1 | +3.3V Power Supply |
| 31 | LVTTL-I | LPMode | Low Power Mode |
| 32 | - | GND | Ground |
| 33 | CML-I | Tx3p | Transmitter Non-Inverted Data Input |
| 34 | CML-I | Tx3n | Transmitter Inverted Data Output* |
| 35 | - | GND | Ground |
| 36 | CML-I | Tx1p | Transmitter Non-Inverted Data Input |
| 37 | CML-I | Tx1n | Transmitter Inverted Data Output* |
| 38 | - | GND | Ground |
The original datasheet describes pins 3, 6, 34, and 37 as transmitter data outputs even though their logic type is CML-I and their symbols identify transmitter inputs. The source wording is retained here for verification before final hardware documentation.
Mechanical Specifications
| Parameter | Specification |
|---|---|
| Form Factor | QSFP+ |
| Electrical Connector | 38-Pin QSFP+ |
| Optical Interface | MPO |
| Fiber Type | OM3 / OM4 Multimode Fiber |
| Optical Configuration | 4-Lane Parallel Transmit / Receive |
| Mechanical Drawing Units | mm |
| Mechanical Dimensions | Refer to Original Drawing |
The original datasheet includes a Mechanical Specifications section, but the numerical dimensions and drawing details are not present in the supplied text.
MPO connector pin count, key orientation, gender, and cable polarity are not specified and must be verified before specifying a compatible patch cable.
Product Variants & Ordering Information
The original ordering table provides the following industrial-temperature version.
| Model | Data Rate | Wavelength | Reach | Fiber Type | Connector | Temperature |
|---|---|---|---|---|---|---|
| DQS4-8M40-SIY8 | 40G | 850nm | 100m OM3 / 150m OM4 | MMF | MPO | -40C to +85C |
OEM/ODM Requirements for Review
Host switch and firmware compatibility
QSFP+ module identification and management information
MPO connector configuration and patch-cable compatibility
Product labeling and packaging
Project-specific optical and temperature qualification
Custom configurations should be confirmed through engineering review before ordering.
40G QSFP+ SR4 Transceiver Module Applications
The 40G QSFP+ SR4 transceiver supports parallel 850nm optical links in compatible 40GbE equipment using OM3 or OM4 multimode fiber.
Data Center Backbone: High-speed optical interconnections between compatible data center switches.
40GbE Network Connectivity: Short-range 40Gbps-class links over multimode fiber.
Switch-to-Switch Interconnections: Parallel optical links between compatible aggregation and core network equipment.
High-Density Optical Cabling: MPO-based connections in structured data center fiber infrastructure.
Typical Network Architecture
A 40G SR4 optical connection uses four parallel transmit channels and four parallel receive channels.
40G QSFP+ Switch -> 40G QSFP+ SR4 Transceiver -> MPO Multimode Fiber Link -> 40G QSFP+ SR4 Transceiver -> Remote 40G Switch
Maximum specified distances:
OM3 Multimode Fiber: 100m
OM4 Multimode Fiber: 150m
The MPO cable configuration and fiber polarity must match the transceiver interfaces and network topology.
Engineering Selection & Installation Guidelines
1. Select OM3 or OM4 Multimode Fiber
Use compatible multimode fiber for the required connection distance. The specified maximum reach is 100m over OM3 and 150m over OM4. Confirm the complete installed channel, including connector and splice losses, before deployment.
2. Verify MPO Connectivity and Polarity
This QSFP+ SR4 module uses an MPO optical interface for parallel transmission. Verify connector pin count, gender, key orientation, and fiber polarity before choosing an MPO trunk or patch cable. These details are not provided in the supplied datasheet.
3. Evaluate Optical Link Performance
The specified transmitter average power is -8.4 to +2.4 dBm per lane, while receiver sensitivity is -11.1 dBm in OMA at BER = 1E-12.
Average optical power and OMA are different measurement definitions. Do not directly subtract these values to claim a validated link budget. Evaluate each lane using the applicable optical test requirements.
4. Check Host Power and Temperature Requirements
The recommended supply range is 3.135V to 3.465V, with specified 1.5W power consumption and 450mA supply current. The DQS4-8M40-SIY8 model operates from -40C to +85C. Confirm QSFP+ host compatibility, thermal conditions, and power capacity before installation.
Frequently Asked Questions
1. What is a 40G QSFP+ SR4 transceiver module?
A 40G QSFP+ SR4 transceiver module is a parallel optical device for 40Gbps-class multimode fiber connections. Spring Optical's 850nm SR4 model uses four 10.3125Gbps transmit channels and supports links up to 100m on OM3 or 150m on OM4 fiber with an MPO optical interface.
2. What is the difference between 40GBASE-SR4 and 40GBASE-LR4?
40GBASE-SR4 uses parallel optical channels over multimode fiber for short-range connections. LR4 is associated with longer-distance single-mode fiber transmission. This product is an 850nm SR4 module designed for OM3 and OM4 fiber, not an LR4 module for single-mode links.
3. What is the maximum transmission distance?
The specified maximum distance is 100m over OM3 multimode fiber and 150m over OM4 multimode fiber. Actual supported distance depends on the installed optical channel, connector losses, cable quality, and the performance limits of the network equipment.
4. Does the module use an MPO connector?
Yes. The ordering information specifies an MPO optical interface. However, the supplied datasheet does not identify the precise MPO pin count, connector gender, key orientation, or polarity. Confirm these details against the mechanical drawing or sample before purchasing the associated fiber cable assembly.
5. Does the 40G QSFP+ SR4 module support DDM?
Yes. The module supports digital diagnostic monitoring of transceiver temperature, supply voltage, transmitter bias current, transmitted optical power, and received optical power. The datasheet specifies temperature accuracy of +/-3C and optical power measurement accuracy of +/-3dB.
6. Is this module suitable for industrial-temperature applications?
The DQS4-8M40-SIY8 model is specified for a case operating temperature range of -40C to +85C. The product features also mention a commercial 0C to +70C range, but the supplied ordering information identifies only the industrial-temperature model.
Quality Assurance & OEM/ODM Manufacturing
Spring Optical supplies optical networking products for telecom operators, network equipment distributors, system integrators, and data center infrastructure projects.
OEM/ODM support can include compatibility review, product identification, labeling, packaging, and project-specific technical requirements.
Relevant Product Verification
Transmitter wavelength and per-lane optical output power
Receiver sensitivity and optical power characteristics
40Gbps-class parallel optical interface performance
Digital diagnostic monitoring functionality
Power supply and electrical interface verification
Operating temperature evaluation
MPO connector configuration and optical connectivity
Product appearance and labeling inspection
Test scope, sampling frequency, and acceptance criteria must be confirmed against the approved production quality plan. No unsupported 100% testing or certification claim is made.
Packing, Storage & Shipping
The original datasheet specifies a storage temperature range of -40C to +85C and relative humidity from 0% to 85%.
Protect the MPO optical connector, host electrical interface, and product housing against dust, mechanical damage, and electrostatic discharge.
Suitable protective packaging, carton quantities, shipment schedules, and delivery arrangements should be confirmed in the purchase order.
Related Products
Explore Spring Optical's optical transceiver modules for 100G, 40G, 25G, 10G, and 1.25G fiber optic networks. Our product range includes multimode, single-mode, and bidirectional transceivers for data centers, telecom networks, and high-speed optical interconnections.
| Related Product | Application |
|---|---|
| 100G QSFP28 SR4 Transceiver Module 850nm 100m MPO-12 | 100GBASE-SR4 multimode Ethernet connections, 70m OM3 / 100m OM4 |
| 25G SFP28 SR Transceiver Module 850nm 100m | 25GBASE-SR short-range multimode Ethernet with duplex LC |
| 25G SFP28 LR Transceiver Module 1310nm 10KM | 25G single-mode dual-fiber Ethernet with duplex LC |
| 25G SFP28 BiDi Transceiver Module 1270/1330nm 10KM | 25G single-fiber bidirectional links with simplex LC |
| 10G SFP+ Transceiver Module 1310nm 20KM | 10G single-mode dual-fiber network connections |
| 10G SFP+ BiDi Transceiver Module 1270/1330nm 20KM | 10G single-fiber bidirectional optical connections |
| 1.25G SFP Transceiver Module 1310/1550nm 20KM | 1.25G single-mode dual-fiber transmission with duplex LC |
| 1.25G BiDi SFP Transceiver Module 1310/1550nm 20KM | 1.25G single-fiber bidirectional links with LC/SC options |
Explore our complete range of Optical Transceiver Modules for additional fiber optic network solutions.
Request Datasheet & Quotation
Contact Spring Optical for the 40G QSFP+ SR4 Transceiver Module datasheet, host compatibility review, MPO interface confirmation, sample evaluation, or project quotation.
Please provide the network equipment model, required fiber type and link distance, MPO cable configuration, and estimated order quantity.
Hot Tags: 40G QSFP+ SR4, 40G QSFP+, QSFP+ Transceiver, Optical Transceiver, 40G QSFP+ Transceiver Module, 40GBASE-SR4, Optical Module, Multimode Transceiver, 40G QSFP+ SR4 MPO, 850nm QSFP+, 40G SR4 150M