Spring Optical Communication is one of the largest and best 100g qsfp28 sr4 transceiver module 850nm 100m mpo-12 ddm multimode optical transceiver manufacturers and suppliers with rich experience. Welcome to buy our high quality products or wholesale our customized 100g qsfp28 sr4 transceiver module 850nm 100m mpo-12 ddm multimode optical transceiver in stock with our factory. Also, free sample is also available if necessary.
The 100G QSFP28 SR4 Transceiver Module provides 103.1Gb/s aggregate transmission through four 25.78125Gbps lanes over multimode fiber. Designed for 100GBASE-SR4 Ethernet, it supports 70m on OM3 and 100m on OM4 with an MPO 1x12 interface, digital diagnostic monitoring (DDM), and commercial 0 to +70C operation.
Product Overview

Spring Optical's 100G QSFP28 SR4 Transceiver Module supports 100Gbps-class optical transmission over multimode fiber. The DQS1-8MA0-SCYM model provides four 25.78125Gbps electrical lanes, with a specified aggregate bit rate of 103.1Gb/s. Its optical interface supports 850nm short-range links of 70m over OM3 and 100m over OM4.
The optical module features a hot-pluggable QSFP28 form factor, a single MPO 1x12 receptacle, a 3.3V power supply, and a digital diagnostic monitoring interface. Its compact configuration supports high-density 100G Ethernet connections.
Designed for 100GBASE-SR4 applications, the multimode transceiver lists compliance with QSFP28 MSA, IEEE 802.3bm, and SFF-8636. The specified case operating temperature is 0 to +70C, and host FEC is required to support the maximum transmission distance.
Key Features & Engineering Advantages
103.1Gb/s Aggregate Data Rate - Supports four 25.78125Gbps lanes for 100GBASE-SR4 Ethernet connectivity.
850nm Multimode Optical Transmission - Designed for short-range 100G optical links using OM3 and OM4 multimode fiber.
70m OM3 / 100m OM4 Reach - Supports defined transmission distances with host FEC enabled for maximum reach.
MPO 1x12 Optical Interface - Provides a single MPO receptacle for parallel multimode fiber connections.
Digital Diagnostic Monitoring (DDM) - Supports module diagnostic functions through the management interface.
Hot-Pluggable QSFP28 Design - Single 3.3V power supply, commercial operating temperature, and QSFP28 MSA compliance.
Technical Specifications
General Specifications
| Parameter | Specification |
|---|---|
| Product Model | DQS1-8MA0-SCYM |
| Document Revision | A0 |
| Product Type | 100G QSFP28 SR4 Optical Transceiver |
| Aggregate Bit Rate | 103.1Gb/s |
| Electrical Interface | 4 x 25Gb/s |
| Ordering Bit Rate per Lane | 25.78125Gbps |
| Nominal Wavelength | 850nm |
| Fiber Type | Multimode Fiber (MMF) |
| OM3 Transmission Distance | 70m |
| OM4 Transmission Distance | 100m |
| Optical Connector | MPO 1x12 |
| Form Factor | Hot-Pluggable QSFP28 |
| Digital Diagnostics | DDMI Supported |
| Power Supply | Single +3.3V |
| Operating Case Temperature | 0 to +70C |
| Application | 100GBASE-SR4 Ethernet |
| Listed Compliance | QSFP28 MSA, IEEE 802.3bm, SFF-8636 |
| Environmental Compliance | RoHS-6 Compliant, Lead-Free |
| Host FEC | Required for Maximum Specified Distance |
Absolute Maximum Ratings
| Parameter | Symbol | Min | Max | Unit |
|---|---|---|---|---|
| Storage Temperature | TS | -40 | 85 | C |
| Storage Ambient Humidity | HA | 0 | 85 | % |
| Supply Voltage | VCC | -0.5 | 3.6 | V |
| Receiver Damage Threshold | - | - | +3.4 | dBm |
Soldering Temperature and Time
| Parameter | Symbol | Specified Value | Unit | Reference |
|---|---|---|---|---|
| Lead Soldering Temperature/Time | TSOLD | 260/10 | C/sec | 1 |
| Lead Soldering Temperature/Time | TSOLD | 360/10 | C/sec | 2 |
Source Notes
Suitable for wave soldering.
Only for soldering by iron.
General Product Characteristics
| Parameter | Symbol | Specified Value | Unit |
|---|---|---|---|
| Aggregate Bit Rate | BR | 103.1 | Gb/s |
| Bit Error Ratio, Pre-FEC | BER | 10-5 | Source notation |
| Link Distance on OM3 MMF | d | 70 | m |
| Link Distance on OM4 MMF | d | 100 | m |
General Product Notes
Supports 100GBASE-SR4 according to IEEE 802.3bm.
Tested with a PRBS 231-1 test pattern, as printed in the source.
Host FEC is required to support the maximum specified distance.
Optical Characteristics - Transmitter
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Average Output Power per Lane | POUT | -6 | - | +2.4 | dBm |
| Extinction Ratio | ER | 2 | - | - | dB |
| Center Wavelength | lambda C | 840 | - | 860 | nm |
| RMS Spectral Width | sigma | - | - | 0.6 | nm |
| Transmitter OFF Output Power | POff | - | - | -30 | dBm |
Transmitter Eye Mask
| Parameter | Value |
|---|---|
| Eye Mask Definition | X1, X2, X3, Y1, Y2, Y3 |
| X1 | 0.30 |
| X2 | 0.38 |
| X3 | 0.45 |
| Y1 | 0.35 |
| Y2 | 0.41 |
| Y3 | 0.50 |
| Hit Ratio | 1.5 x 10-3 hits/sample |
Optical Characteristics - Receiver
| Parameter | Symbol | Specified Value | Unit | Notes |
|---|---|---|---|---|
| Input Optical Wavelength | lambda IN | 840 to 860 | nm | - |
| Receiver Sensitivity, OMA per Lane | RSENS | -10.3 | dBm | BER = 5E-5 |
| Input Saturation Power (Overload) | PSAT | +2.4 | dBm | - |
| Receiver Reflectance | Rfl | -12 | dBm | Source unit |
| Loss of Signal Assert | PA | -30 | dBm | - |
| Loss of Signal Deassert | PD | -12 | dBm | - |
| LOS Hysteresis | PD - PA | 0.5 | dB | - |
Optical Test Notes
Transmitter eye mask hit ratio: 1.5 x 10-3 hit/sample.
The original optical test note states: "Measured with PRBS 2^31-1 test pattern 225.78125Gbps. BER=E-12."
Electrical Interface Characteristics
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Supply Voltage | VCC1, VCCTX, VCCRX | 3.15 | - | 3.45 | V |
| Supply Current | ICC | - | - | 750 | mA |
Transmitter Electrical Characteristics - Per Lane
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Input Differential Impedance | Rin | 90 | 100 | 110 | Ohm |
| Single-Ended Input Voltage Tolerance | VinT | -0.3 | - | 4.0 | V |
| Single-Ended Data Input Swing | Vin,pp | 200 | - | 1000 | mV |
Receiver Electrical Characteristics - Per Lane
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Output Differential Impedance | Rout | 90 | 100 | 110 | Ohm |
| Single-Ended Data Output Swing | Vout,pp | 200 | - | 1000 | mV |
| Single-Ended Output Voltage | VoutR | -0.3 | - | 4.0 | V |
Digital Diagnostic Functions
The DQS1-8MA0-SCYM supports a Digital Diagnostic Monitor interface.
| Parameter | Specification |
|---|---|
| DDM / DDMI | Supported |
| Digital Diagnostic Functions | Refer to Original Datasheet Section VII |
| Diagnostic Accuracy | Not Specified in Supplied Text |
| Detailed Management Information | Refer to Original Datasheet Graphic |
The original specification includes a Digital Diagnostic Functions section without readable numerical monitoring parameters in the supplied text.
QSFP28 Pin Assignment and Description
The 100G QSFP28 SR4 transceiver uses a 38-pin host interface.
| Pin | Symbol | Description | Note |
|---|---|---|---|
| 1 | GND | Ground | 1 |
| 2 | Tx2n | Transmitter Inverted Data Input | - |
| 3 | Tx2p | Transmitter Non-Inverted Data Input | - |
| 4 | GND | Ground | 1 |
| 5 | Tx4n | Transmitter Inverted Data Input | - |
| 6 | Tx4p | Transmitter Non-Inverted Data Input | - |
| 7 | GND | Ground | 1 |
| 8 | ModSe1L | Module Select | - |
| 9 | ResetL | Module Reset | - |
| 10 | Vcc Rx | +3.3V Receiver Power Supply | - |
| 11 | SCL | Two-Wire Serial Interface Clock | - |
| 12 | SDA | Two-Wire Serial Interface Data | - |
| 13 | GND | Ground | 1 |
| 14 | Rx3p | Receiver Non-Inverted Data Output | - |
| 15 | Rx3n | Receiver Inverted Data Output | - |
| 16 | GND | Ground | 1 |
| 17 | Rx1p | Receiver Non-Inverted Data Output | - |
| 18 | Rx1n | Receiver Inverted Data Output | - |
| 19 | GND | Ground | 1 |
| 20 | GND | Ground | 1 |
| 21 | Rx2n | Receiver Inverted Data Output | - |
| 22 | Rx2p | Receiver Non-Inverted Data Output | - |
| 23 | GND | Ground | 1 |
| 24 | Rx4n | Receiver Inverted Data Output | - |
| 25 | Rx4p | Receiver Non-Inverted Data Output | - |
| 26 | GND | Ground | 1 |
| 27 | ModPrSL | Module Present | - |
| 28 | IntL | Interrupt | - |
| 29 | Vcc Tx | +3.3V Transmitter Power Supply | - |
| 30 | Vcc1 | +3.3V Power Supply | - |
| 31 | LPMode | Low Power Mode | - |
| 32 | GND | Ground | 1 |
| 33 | Tx3p | Transmitter Non-Inverted Data Input | - |
| 34 | Tx3n | Transmitter Inverted Data Input | - |
| 35 | GND | Ground | 1 |
| 36 | Tx1p | Transmitter Non-Inverted Data Input | - |
| 37 | Tx1n | Transmitter Inverted Data Input | - |
| 38 | GND | Ground | 1 |
Pin Note
Circuit ground is internally isolated from chassis ground.
Recommended Interface Circuit
The original product specification includes a Recommended Interface Circuit in Section VIII.
The module uses a QSFP28 electrical interface with separate power, data, module-control, and two-wire serial management connections.
The original recommended circuit drawing should be placed in this section of the product page.
Mechanical Specifications
| Parameter | Specification |
|---|---|
| Form Factor | QSFP28 |
| Installation Type | Hot-Pluggable |
| Optical Connector | MPO 1x12 |
| Fiber Type | Multimode Fiber |
| Supported Fiber Grades | OM3 / OM4 |
| Mechanical Dimensions | Refer to Original Drawing |
| Drawing Unit | mm |
The original specification includes a Mechanical Specifications drawing in Section IX. No numerical dimensions are present in the supplied text.
Product Variants & Ordering Information
The source ordering information specifies one commercial-temperature model.
| Part Number | Bit Rate | Wavelength | Distance | Fiber Type | DDMI | Connector | Temperature |
|---|---|---|---|---|---|---|---|
| DQS1-8MA0-SCYM | 25.78125Gbps per lane | 850nm | 100m OM4 | Multimode | Yes | MPO 1x12 | 0 to +70C |
The product also specifies 70m maximum reach on OM3 multimode fiber.
OEM/ODM Requirements for Review
QSFP28 host switch compatibility
Module identification and management requirements
Product labeling and packaging
MPO 1x12 connectivity requirements
Project-specific optical performance requirements
100G QSFP28 SR4 Transceiver Module Applications
The 100G QSFP28 SR4 optical transceiver is designed for 100GBASE-SR4 Ethernet over multimode fiber.
Data Center Interconnections: 100Gbps-class optical links between compatible data center switches.
100GBASE-SR4 Ethernet: Parallel multimode fiber connections using four optical lanes.
High-Speed Server Networking: Compatible 100G network equipment interconnections within data center infrastructure.
Structured Fiber Cabling: MPO-based optical connections using OM3 and OM4 multimode fiber.
Typical Network Architecture
The 100G QSFP28 SR4 transceiver supports parallel optical communication between compatible network devices.
100G Switch A -> QSFP28 SR4 Module -> MPO 1x12 OM3/OM4 Multimode Fiber Link -> QSFP28 SR4 Module -> 100G Switch B
Specified Distances
OM3 Multimode Fiber: Up to 70m
OM4 Multimode Fiber: Up to 100m
Host FEC is required to support the maximum specified transmission distance.
Engineering Selection & Installation Guidelines
1. Select the Correct Multimode Fiber
Use OM3 or OM4 multimode fiber according to the required link distance. The maximum specified distances are 70m over OM3 and 100m over OM4. Confirm the installed optical channel and connector configuration before deployment.
2. Verify MPO 1x12 Connectivity
The module uses a single MPO 1x12 optical receptacle. Select compatible MPO cabling and ensure that the connection arrangement supports the transmit and receive fiber paths required by the equipment.
3. Configure Host FEC
The datasheet specifies that host FEC is required to support the maximum link distance under 100GBASE-SR4. Confirm that the host network equipment supports the required FEC configuration before commissioning the optical link.
4. Check Electrical and Optical Requirements
The module uses a 3.3V power supply, with a specified maximum supply current of 750mA. Verify host port power capacity, optical transmitter output power, receiver sensitivity, and the applicable channel loss requirements before installation.
Frequently Asked Questions
1. What is a 100G QSFP28 SR4 transceiver module?
A 100G QSFP28 SR4 transceiver module is a hot-pluggable optical device designed for 100Gbps-class transmission over multimode fiber. Spring Optical's DQS1-8MA0-SCYM model supports a 103.1Gb/s aggregate bit rate through four 25.78125Gbps lanes, with an MPO 1x12 optical interface.
2. What is the difference between 100G QSFP28 SR4 and LR4?
100G QSFP28 SR4 is designed for short-range multimode fiber connections, while LR4 is used for longer-distance single-mode fiber applications. This SR4 model operates at 850nm and supports maximum distances of 70m on OM3 and 100m on OM4.
3. What is the maximum transmission distance?
The specified maximum distance is 70m using OM3 multimode fiber and 100m using OM4 multimode fiber. The datasheet requires host FEC for maximum reach. Actual installation performance also depends on the optical channel and connected network equipment.
4. Does the module support digital diagnostic monitoring?
Yes. The DQS1-8MA0-SCYM includes a Digital Diagnostic Monitor interface and lists SFF-8636 compliance. The supplied text confirms DDM support but does not provide numerical diagnostic accuracy or a readable diagnostic memory map.
5. What optical connector does the 100G QSFP28 SR4 module use?
The product uses a single MPO 1x12 optical receptacle. This interface supports parallel-fiber connectivity for compatible 100GBASE-SR4 equipment. MPO cable configuration should match the equipment's optical connection requirements.
6. What are the power and temperature requirements?
The transceiver operates from 0 to +70C with a nominal 3.3V power supply. The electrical specification lists a 3.15V to 3.45V supply range and a supply current of 750mA. The product is specified for commercial-temperature applications.
Quality Assurance & OEM/ODM Manufacturing
Spring Optical supplies optical communication products for telecom operators, data center system integrators, equipment distributors, and networking infrastructure projects.
OEM/ODM support can include host compatibility review, product identification, packaging customization, and project-specific technical coordination.
Relevant Product Verification
Aggregate and per-lane data rate
Optical wavelength and output power
Receiver sensitivity and saturation performance
Optical signal and eye mask measurements
Electrical interface and power supply parameters
Digital diagnostic functionality
MPO connector and fiber connectivity
Host FEC and link performance
Product testing arrangements and acceptance criteria can be confirmed according to the applicable procurement requirements.
Packing, Storage & Shipping
The specified storage temperature range is -40 to +85C, with storage ambient humidity from 0% to 85%.
Protect the QSFP28 electrical interface and MPO optical connector from dust, physical damage, and electrostatic discharge. Keep optical interfaces covered when not connected.
Packing quantities, carton dimensions, delivery schedules, and shipping arrangements are confirmed according to purchase order requirements.
Related Products
Explore Spring Optical's optical transceiver modules for 100G, 40G, 25G, 10G, and 1.25G fiber optic networks. Our product range includes multimode, single-mode, and bidirectional transceivers for data centers, telecom networks, and high-speed optical interconnections.
| Related Product | Application |
|---|---|
| 40G QSFP+ SR4 Transceiver Module 850nm 150m MPO | 40G multimode data center links, 100m OM3 / 150m OM4 |
| 25G SFP28 SR Transceiver Module 850nm 100m | 25GBASE-SR short-range multimode Ethernet with duplex LC |
| 25G SFP28 LR Transceiver Module 1310nm 10KM | 25G single-mode dual-fiber Ethernet with duplex LC |
| 25G SFP28 BiDi Transceiver Module 1270/1330nm 10KM | 25G single-fiber bidirectional links with simplex LC |
| 10G SFP+ Transceiver Module 1310nm 20KM | 10G single-mode dual-fiber network connections |
| 10G SFP+ BiDi Transceiver Module 1270/1330nm 20KM | 10G single-fiber bidirectional optical connections |
| 1.25G SFP Transceiver Module 1310/1550nm 20KM | 1.25G single-mode dual-fiber transmission with duplex LC |
| 1.25G BiDi SFP Transceiver Module 1310/1550nm 20KM | 1.25G single-fiber bidirectional links with LC/SC options |
Explore our complete range of Optical Transceiver Modules for additional fiber optic network solutions.
Request Datasheet & Quotation
Contact Spring Optical for the 100G QSFP28 SR4 Transceiver Module datasheet, compatibility requirements, sample evaluation, OEM/ODM options, or project quotation.
Please provide the host switch model, multimode fiber type, required distance, MPO cable requirements, and purchase quantity.
Hot Tags: 100G QSFP28 SR4, 100G QSFP28, QSFP28 Transceiver, Optical Transceiver, QSFP28 Transceiver Module, 100GBASE-SR4, Optical Module, Multimode Transceiver, 850nm QSFP28, 100G QSFP28 MPO, 100G SR4 100m