Spring Optical Communication is one of the largest and best 25g sfp28 bidi transceiver module 1270/1330nm 10km single mode simplex lc ddm manufacturers and suppliers with rich experience. Welcome to buy our high quality products or wholesale our customized 25g sfp28 bidi transceiver module 1270/1330nm 10km single mode simplex lc ddm in stock with our factory. Also, free sample is also available if necessary.
The 25G SFP28 BiDi Transceiver Module supports 25.78Gbps bidirectional optical transmission over a single fiber up to 10KM. Featuring complementary 1270nm/1330nm DFB lasers, a PIN/TIA receiver, simplex LC interface, and digital diagnostic monitoring (DDM), it provides single-fiber connectivity for compatible high-speed storage, switch-to-switch, and 25G network interconnections.
Product Overview

Spring Optical's 25G SFP28 BiDi Transceiver Module provides 25.78Gbps bidirectional transmission over distances up to 10KM using 9/125um single-mode fiber. The DPP2-2325 and DPP2-3225 series uses complementary 1270nm and 1330nm DFB lasers to transmit and receive optical signals through one simplex LC connection.
The optical module integrates an uncooled DFB laser transmitter, PIN photodiode with transimpedance amplifier (TIA), and a two-wire management interface. SFF-8472 digital diagnostic monitoring provides access to temperature, laser bias current, TX/RX optical power, and supply voltage.
Designed in accordance with SFP28 MSA, SFF-8431, and SFF-8472 specifications, the transceiver supports compatible high-speed storage networks and switch-to-switch connections. Commercial and industrial temperature configurations are available.
Key Features & Engineering Advantages
25.78Gbps Data Rate & 10KM Reach - Supports bidirectional optical links over up to 10KM of single-mode fiber.
1270/1330nm BiDi Wavelengths - Uses complementary uncooled DFB lasers for single-fiber transmit and receive communication.
Simplex LC Fiber Interface - Enables bidirectional connectivity through one optical fiber instead of a conventional duplex pair.
Digital Diagnostic Monitoring (DDM) - Provides real-time access to optical power, module temperature, laser bias current, and voltage.
Commercial & Industrial Temperature Options - Available for 0 to +70C and -40 to +85C operating environments.
Hot-Pluggable SFP28 Design - Single 3.3V supply with SFF-8431, SFF-8472, RoHS, and Class 1 laser safety specifications.
Technical Specifications
General Specifications
| Parameter | Specification |
|---|---|
| Product Series | DPP2-2325 / DPP2-3225 |
| Product Type | 25G SFP28 BiDi Optical Transceiver |
| Data Rate | Up to 25.78Gbps |
| Transmission Distance | 10KM |
| Fiber Type | 9/125um Single Mode Fiber |
| Transmission Mode | Single-Fiber Bidirectional |
| Wavelength Pair A | TX1270nm / RX1330nm |
| Wavelength Pair B | TX1330nm / RX1270nm |
| Transmitter | Uncooled DFB Laser |
| Receiver | PIN Photodiode with TIA |
| Optical Connector | Simplex LC |
| Form Factor | Hot-Pluggable SFP28, 20-Pin |
| Supply Voltage | Single +3.3V DC |
| Digital Diagnostics | SFF-8472 DDM |
| Management Interface | Two-Wire Serial Interface |
| SFP28 Compliance | SFP28 MSA |
| Electrical Interface Standard | SFF-8431 |
| Diagnostics Standard | SFF-8472 |
| Laser Safety | Class 1 |
| Environmental Compliance | RoHS |
| Commercial Operating Temperature | 0 to +70C |
| Industrial Operating Temperature | -40 to +85C |
| Product Datasheet Revision | Rev. 1.0 |
Absolute Maximum Ratings
| Parameter | Symbol | Min | Max | Unit |
|---|---|---|---|---|
| Storage Temperature | TS | -40 | +85 | C |
| Supply Voltage | VCC3 | 3.1 | 3.6 | V |
| Relative Humidity, Non-Condensing | RH | 5 | 95 | % |
Note: The source labels the supply voltage range above under Absolute Maximum Ratings. Normal operation should follow the Recommended Operating Conditions below.
Recommended Operating Conditions
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Case Temperature - Commercial | TC | 0 | - | 70 | C |
| Case Temperature - Industrial | TC | -40 | - | 85 | C |
| Power Supply Voltage | VCC3 | 3.135 | 3.3 | 3.465 | V |
| Supply Current | ICC3 | - | - | 450 | mA |
| Power Dissipation | PD | - | - | 1.5 | W |
| Data Rate | - | - | 25.78 | - | Gbps |
| Transmission Distance | - | - | - | 10 | km |
Temperature applicability:
Commercial: DPP2-2325-1CY1 and DPP2-3225-1CY1.
Industrial: DPP2-2325-1IY1 and DPP2-3225-1IY1.
Optical and Electrical Characteristics - Transmitter
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Center Wavelength - TX1270 | lambda c | 1250 | 1270 | 1290 | nm | TX1270nm |
| Center Wavelength - TX1330 | lambda c | 1310 | 1330 | 1350 | nm | TX1330nm |
| Laser OFF Power | Poff | - | - | -30 | dBm | - |
| Average Optical Output Power | Pavg | -4 | - | +2 | dBm | - |
| Spectral Width (-20dB) | - | - | - | 1 | nm | DFB Laser |
| Side Mode Suppression Ratio | SMSR | 30 | - | - | dB | - |
| Extinction Ratio | ER | 3.5 | - | - | dB | - |
| TX Input Differential Swing | VI | 180 | - | 700 | mVpp | - |
Transmitter Disable Control
| Control State | Min | Max | Unit |
|---|---|---|---|
| TX Disable - Disabled | 2 | VCC | V |
| TX Disable - Enabled | VEE | VEE + 0.8 | V |
A HIGH TX_Disable input turns off the transmitter laser. The source specifies the corresponding voltage levels above.
Optical and Electrical Characteristics - Receiver
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Center Wavelength - RX1270 | lambda c | 1250 | 1270 | 1290 | nm | RX1270nm |
| Center Wavelength - RX1330 | lambda c | 1310 | 1330 | 1350 | nm | RX1330nm |
| Receiver Sensitivity | S | - | - | -12 | dBm | Note 1 |
| LOS Assert | LOS A | -35 | - | - | dBm | - |
| LOS Deassert | LOS D | - | - | -13 | dBm | - |
| LOS Hysteresis | LOSH | 0.5 | - | 6 | dB | - |
| Receiver Overload | Pov | - | - | +1 | dBm | - |
| RX Output Differential Swing | Vo | 300 | - | 850 | mVpp | - |
Receiver Test Condition
Receiver sensitivity is specified as the minimum average optical input power measured at an extinction ratio of 4 dB, using a 2^31-1 PRBS pattern and BER below 5E-5.
Control and Status I/O Timing
| Parameter | Symbol | Min | Max | Unit |
|---|---|---|---|---|
| TX Disable Assert Time | t_off | - | 100 | us |
| TX Disable Negate Time | t_on | - | 1 | ms |
| Initialization Including TX Fault Reset | t_init | - | 300 | ms |
| TX Fault Assert Time | t_fault | - | 100 | us |
| TX Fault Reset Time | t_reset | 10 | - | us |
| LOS Assert Time | t_loss_on | - | 100 | us |
| LOS Deassert Time | t_loss_off | - | 100 | us |
| Serial ID Clock Rate | f_serial_clock | 100 | 400 | kHz |
Timing Conditions
TX Disable Assert: From the rising edge of TX Disable until optical output falls below 10% of nominal.
TX Disable Negate: From the falling edge of TX Disable until modulated optical output exceeds 90% of nominal.
Initialization: From power-on or negation of TX Fault using TX Disable.
TX Fault Assert: From fault occurrence to TX Fault assertion.
TX Fault Reset: Minimum time TX Disable must remain HIGH to reset TX Fault.
LOS Assert: From entering the LOS state until RX_LOS assertion.
LOS Deassert: From leaving the LOS state until RX_LOS deassertion.
The source's eighth explanatory note describes Rate Select timing rather than the Serial ID Clock Rate listed in the table. The serial clock frequency requires confirmation against the original approved design.
Pin Assignment and Description
| Pin | Symbol | Description | Note |
|---|---|---|---|
| 1 | VeeT | Module Transmitter Ground | 1 |
| 2 | TX_Fault | Module Transmitter Fault | 2 |
| 3 | TX_Disable | Transmitter Disable; Turns Off Laser Output | 3 |
| 4 | SDA | Two-Wire Serial Interface Data Line (MOD-DEF2) | 4 |
| 5 | SCL | Two-Wire Serial Interface Clock (MOD-DEF1) | 4 |
| 6 | MOD_ABS | Module Absent; Connected to VeeT or VeeR | 5 |
| 7 | RS | Rate Select; Refer to Source Description | 6 |
| 8 | RX_LOS | Receiver Loss-of-Signal Indication | 2 |
| 9 | VeeR | Module Receiver Ground | 1 |
| 10 | VeeR | Module Receiver Ground | 1 |
| 11 | VeeR | Module Receiver Ground | 1 |
| 12 | RD- | Receiver Inverted Data Output | - |
| 13 | RD+ | Receiver Non-Inverted Data Output | - |
| 14 | VeeR | Module Receiver Ground | 1 |
| 15 | VccR | Module Receiver 3.3V Supply | - |
| 16 | VccT | Module Transmitter 3.3V Supply | - |
| 17 | VeeT | Module Transmitter Ground | 1 |
| 18 | TD+ | Transmitter Non-Inverted Data Input | - |
| 19 | TD- | Transmitter Inverted Data Input | - |
| 20 | VeeT | Module Transmitter Ground | 1 |
Pin Notes
VeeR and VeeT signal grounds are isolated from the module case.
TX_Fault and RX_LOS are open-collector/open-drain outputs. The host requires 4.7k-10k Ohm pull-up resistors to Host_Vcc. No module pin should exceed VccT/R + 0.5V.
TX_Disable is an open-collector/open-drain input with an internal 4.7k-10k Ohm pull-up to VccT.
SDA and SCL follow the two-wire electrical interface referenced in SFF-8472 Section 4.2.
MOD_ABS requires a 4.7k-10k Ohm pull-up to Host_Vcc on the host board.
The source references SFF-8079 and states pin 7 may be used for RS0, followed by "Not use." The same source also describes 10.3GBd/1.25GBd rate-selection behavior. This appears inconsistent with the 25.78Gbps product and requires engineering confirmation.
Mechanical Specifications
| Parameter | Specification |
|---|---|
| Form Factor | SFP28 |
| Host Interface | Hot-Pluggable 20-Pin |
| Optical Interface | Simplex LC |
| Fiber Type | 9/125um Single Mode |
| Fiber Configuration | Single-Fiber Bidirectional |
| Mechanical Dimensions | Refer to Approved Mechanical Drawing |
The supplied text includes a Mechanical Specifications section but does not provide numerical dimensions or tolerances. Insert the approved original engineering drawing here.
Product Variants & Ordering Information
Spring Optical's 25G SFP28 BiDi series includes complementary 1270nm/1330nm wavelength options in commercial and industrial temperature grades.
| Model | TX / RX Wavelength | TX Power | RX Sensitivity | Distance | Temperature |
|---|---|---|---|---|---|
| DPP2-2325-1CY1 | TX1270 / RX1330nm | -4 to +2 dBm | -12 dBm | 10KM | 0 to +70C |
| DPP2-3225-1CY1 | TX1330 / RX1270nm | -4 to +2 dBm | -12 dBm | 10KM | 0 to +70C |
| DPP2-2325-1IY1 | TX1270 / RX1330nm | -4 to +2 dBm | -12 dBm | 10KM | -40 to +85C |
| DPP2-3225-1IY1 | TX1330 / RX1270nm | -4 to +2 dBm | -12 dBm | 10KM | -40 to +85C |
All four models are specified as SFP28, 25.78Gbps, DDM-enabled, RoHS compliant, and equipped with simplex LC optical interfaces.
Wavelength Pairing Requirement
A-side: TX1270nm / RX1330nm
B-side: TX1330nm / RX1270nm
A valid BiDi link requires one complementary module at each end of the same fiber.
OEM/ODM Requirements for Review
Host equipment and firmware compatibility
EEPROM or module identification requirements
Product labeling and packaging
Commercial or industrial temperature configuration
Project-specific testing and qualification
25G SFP28 BiDi Transceiver Module Applications
The 25G SFP28 BiDi optical transceiver supports single-fiber high-speed connections in compatible optical networking systems.
High-Speed Storage Area Networks: 25G-class links between compatible storage network devices.
Switch-to-Switch Interconnections: Bidirectional optical communication between network switches.
High-Speed Network Interconnects: 25.78Gbps optical links across single-mode fiber infrastructure.
Single-Fiber Optical Links: Point-to-point communication where a complementary wavelength pair is available.
Typical Network Architecture
A 25G BiDi fiber link carries both transmit and receive signals over one single-mode fiber using complementary wavelengths.
25G Switch A -> SFP28 BiDi A (TX1270 / RX1330) -> Simplex LC / One SMF (up to 10KM) -> SFP28 BiDi B (TX1330 / RX1270) -> 25G Switch B
Use one TX1270/RX1330 module and one TX1330/RX1270 module. Do not install two modules with the same wavelength configuration at opposite ends.
Engineering Selection & Installation Guidelines
1. Confirm the Complementary Wavelength Pair
The 1270nm and 1330nm variants must be paired correctly. A TX1270/RX1330 module communicates with a TX1330/RX1270 module through one single-mode fiber. Two identical wavelength variants do not form a valid bidirectional link.
2. Evaluate the Optical Power Budget
The source specifies minimum average TX power of -4 dBm and receiver sensitivity of -12 dBm.
Calculated Optical Power Budget = -4 dBm - (-12 dBm) = 8 dB
This is a nominal calculation based on the published receiver sensitivity at BER below 5E-5, not a guaranteed error-free link budget. Include fiber attenuation, connector and splice losses, test conditions, and system margin before confirming a 10KM installation.
3. Check Receiver Overload and Host Power
Receiver overload is specified as +1 dBm. Verify that the received optical level stays within the allowable receiver range.
The module uses a nominal 3.3V supply, with a specified supply current of 450mA and power dissipation of 1.5W in the recommended conditions table. Confirm host port power capacity before installation.
4. Verify Host Compatibility and Optical Handling
Confirm SFP28 interface support, EEPROM requirements, and 25.78Gbps host capability. Clean the simplex LC connector before insertion, use suitable ESD protection, and avoid looking directly into an active optical port.
Frequently Asked Questions
1. What is a 25G SFP28 BiDi transceiver module?
A 25G SFP28 BiDi transceiver is a hot-pluggable optical module that uses separate transmit and receive wavelengths to carry bidirectional data over one fiber. Spring Optical's 1270/1330nm series supports up to 25.78Gbps over a 10KM single-mode fiber link with a simplex LC connector.
2. Does the 25G BiDi module require one fiber or two?
It requires one single-mode fiber. A BiDi transceiver uses different optical wavelengths for transmission and reception over the same fiber. The two endpoints must use complementary wavelength configurations rather than identical modules, and both must be compatible with the installed fiber and host equipment.
3. How should 1270nm and 1330nm BiDi modules be paired?
Use a TX1270/RX1330 module at one endpoint and a TX1330/RX1270 module at the other endpoint. The DPP2-2325 series provides the 1270nm transmitter, while DPP2-3225 provides the 1330nm transmitter. Choose the appropriate commercial or industrial temperature variant for each installation.
4. What is the optical power budget of this 10KM transceiver?
The calculated budget is 8 dB based on minimum transmitter power of -4 dBm and receiver sensitivity of -12 dBm. The sensitivity is measured under the source's specified BER and PRBS test conditions. Actual link design must account for fiber losses, connectors, splices, and appropriate engineering margin.
5. Does the module support digital diagnostic monitoring?
Yes. It supports SFF-8472 digital diagnostic monitoring through a two-wire serial interface. Available monitoring parameters include module temperature, supply voltage, transmitter laser bias current, transmitted optical power, and received optical power. The host equipment must support the diagnostic interface to read these values.
6. What operating temperature options are available?
The commercial versions operate from 0 to +70C, and industrial versions support -40 to +85C. Both ranges are available with 1270nm or 1330nm transmitters, allowing customers to select complementary BiDi modules for the required network operating conditions.
Quality Assurance & OEM/ODM Manufacturing
Spring Optical supplies optical communication components for telecom operators, ISPs, system integrators, network equipment vendors, and distributors.
OEM/ODM support is available for host compatibility review, module identification, packaging, labeling, and project-specific qualification requirements.
Relevant Product Verification
Transmitter center wavelength and output power
Receiver sensitivity and overload performance
Optical extinction ratio and spectral characteristics
Digital diagnostic monitoring functionality
Host electrical interface verification
Commercial and industrial temperature evaluation
Wavelength pairing and link testing
Simplex LC interface and product inspection
Actual testing coverage and inspection frequency should be confirmed through the approved quality control plan.
Packing, Storage & Shipping
The specified storage temperature is -40 to +85C, with 5%-95% relative humidity under non-condensing conditions.
Protect the simplex LC optical connector from dust and physical damage. Follow ESD-safe handling procedures during storage, installation, and transportation.
Packing quantities, carton dimensions, delivery schedules, and shipping arrangements should be confirmed against the purchase order.
Related Products
| Product | Application |
|---|---|
| 25G SFP28 LR Transceiver Module | Dual-fiber 1310nm single-mode links |
| 25G SFP28 SR Transceiver Module | Short-range multimode connections |
| 10G SFP+ BiDi Transceiver | Lower-speed single-fiber optical links |
| 100G QSFP28 LR4 Transceiver | Higher-speed single-mode network links |
| LC Simplex Single Mode Patch Cord | Single-fiber BiDi connections |
| Fiber Optic Patch Panel | Fiber termination and distribution |
Request Datasheet & Quotation
Contact Spring Optical for the 25G SFP28 BiDi Transceiver Module datasheet, compatible wavelength pair selection, OEM/ODM requirements, sample evaluation, or project quotation.
Please provide the host equipment model, required TX/RX wavelength configuration, operating temperature range, and purchase quantity.
Hot Tags: 25G SFP28 BIDI, 25G SFP28 BiDi Transceiver Module, 25G SFP28, SFP28 Transceiver, Optical Transceiver, SFP28 Transceiver Module, Optical Module, Transceiver Module, 25G Optical Transceiver, 1270/1330nm BiDi Transceiver, 25G BiDi 10KM, Single Fiber SFP28