25G SFP28 BiDi Transceiver Module 1270/1330nm 10KM Single Mode Simplex LC DDM

25G SFP28 BiDi Transceiver Module 1270/1330nm 10KM Single Mode Simplex LC DDM
Details:
·25.78Gbps Data Rate & 10KM Reach - Supports bidirectional optical links over up to 10KM of single-mode fiber.
·1270/1330nm BiDi Wavelengths - Uses complementary uncooled DFB lasers for single-fiber transmit and receive communication.
·Simplex LC Fiber Interface - Enables bidirectional connectivity through one optical fiber instead of a conventional duplex pair.
·Digital Diagnostic Monitoring (DDM) - Provides real-time access to optical power, module temperature, laser bias current, and voltage.
·Commercial & Industrial Temperature Options - Available for 0 to +70C and -40 to +85C operating environments.
·Hot-Pluggable SFP28 Design - Single 3.3V supply with SFF-8431, SFF-8472, RoHS, and Class 1 laser safety specifications.
Send Inquiry
Description
Send Inquiry

Spring Optical Communication is one of the largest and best 25g sfp28 bidi transceiver module 1270/1330nm 10km single mode simplex lc ddm manufacturers and suppliers with rich experience. Welcome to buy our high quality products or wholesale our customized 25g sfp28 bidi transceiver module 1270/1330nm 10km single mode simplex lc ddm in stock with our factory. Also, free sample is also available if necessary.

 

The 25G SFP28 BiDi Transceiver Module supports 25.78Gbps bidirectional optical transmission over a single fiber up to 10KM. Featuring complementary 1270nm/1330nm DFB lasers, a PIN/TIA receiver, simplex LC interface, and digital diagnostic monitoring (DDM), it provides single-fiber connectivity for compatible high-speed storage, switch-to-switch, and 25G network interconnections.

Product Overview

25g-sfp28-bidi-transceiver-10km

Spring Optical's 25G SFP28 BiDi Transceiver Module provides 25.78Gbps bidirectional transmission over distances up to 10KM using 9/125um single-mode fiber. The DPP2-2325 and DPP2-3225 series uses complementary 1270nm and 1330nm DFB lasers to transmit and receive optical signals through one simplex LC connection.

The optical module integrates an uncooled DFB laser transmitter, PIN photodiode with transimpedance amplifier (TIA), and a two-wire management interface. SFF-8472 digital diagnostic monitoring provides access to temperature, laser bias current, TX/RX optical power, and supply voltage.

Designed in accordance with SFP28 MSA, SFF-8431, and SFF-8472 specifications, the transceiver supports compatible high-speed storage networks and switch-to-switch connections. Commercial and industrial temperature configurations are available.

Key Features & Engineering Advantages

25.78Gbps Data Rate & 10KM Reach - Supports bidirectional optical links over up to 10KM of single-mode fiber.

1270/1330nm BiDi Wavelengths - Uses complementary uncooled DFB lasers for single-fiber transmit and receive communication.

Simplex LC Fiber Interface - Enables bidirectional connectivity through one optical fiber instead of a conventional duplex pair.

Digital Diagnostic Monitoring (DDM) - Provides real-time access to optical power, module temperature, laser bias current, and voltage.

Commercial & Industrial Temperature Options - Available for 0 to +70C and -40 to +85C operating environments.

Hot-Pluggable SFP28 Design - Single 3.3V supply with SFF-8431, SFF-8472, RoHS, and Class 1 laser safety specifications.

Technical Specifications

General Specifications

Parameter Specification
Product Series DPP2-2325 / DPP2-3225
Product Type 25G SFP28 BiDi Optical Transceiver
Data Rate Up to 25.78Gbps
Transmission Distance 10KM
Fiber Type 9/125um Single Mode Fiber
Transmission Mode Single-Fiber Bidirectional
Wavelength Pair A TX1270nm / RX1330nm
Wavelength Pair B TX1330nm / RX1270nm
Transmitter Uncooled DFB Laser
Receiver PIN Photodiode with TIA
Optical Connector Simplex LC
Form Factor Hot-Pluggable SFP28, 20-Pin
Supply Voltage Single +3.3V DC
Digital Diagnostics SFF-8472 DDM
Management Interface Two-Wire Serial Interface
SFP28 Compliance SFP28 MSA
Electrical Interface Standard SFF-8431
Diagnostics Standard SFF-8472
Laser Safety Class 1
Environmental Compliance RoHS
Commercial Operating Temperature 0 to +70C
Industrial Operating Temperature -40 to +85C
Product Datasheet Revision Rev. 1.0

Absolute Maximum Ratings

Parameter Symbol Min Max Unit
Storage Temperature TS -40 +85 C
Supply Voltage VCC3 3.1 3.6 V
Relative Humidity, Non-Condensing RH 5 95 %

Note: The source labels the supply voltage range above under Absolute Maximum Ratings. Normal operation should follow the Recommended Operating Conditions below.

Recommended Operating Conditions

Parameter Symbol Min Typ Max Unit
Case Temperature - Commercial TC 0 - 70 C
Case Temperature - Industrial TC -40 - 85 C
Power Supply Voltage VCC3 3.135 3.3 3.465 V
Supply Current ICC3 - - 450 mA
Power Dissipation PD - - 1.5 W
Data Rate - - 25.78 - Gbps
Transmission Distance - - - 10 km

Temperature applicability:

Commercial: DPP2-2325-1CY1 and DPP2-3225-1CY1.

Industrial: DPP2-2325-1IY1 and DPP2-3225-1IY1.

Optical and Electrical Characteristics - Transmitter

Parameter Symbol Min Typ Max Unit Notes
Center Wavelength - TX1270 lambda c 1250 1270 1290 nm TX1270nm
Center Wavelength - TX1330 lambda c 1310 1330 1350 nm TX1330nm
Laser OFF Power Poff - - -30 dBm -
Average Optical Output Power Pavg -4 - +2 dBm -
Spectral Width (-20dB) - - - 1 nm DFB Laser
Side Mode Suppression Ratio SMSR 30 - - dB -
Extinction Ratio ER 3.5 - - dB -
TX Input Differential Swing VI 180 - 700 mVpp -

Transmitter Disable Control

Control State Min Max Unit
TX Disable - Disabled 2 VCC V
TX Disable - Enabled VEE VEE + 0.8 V

A HIGH TX_Disable input turns off the transmitter laser. The source specifies the corresponding voltage levels above.

Optical and Electrical Characteristics - Receiver

Parameter Symbol Min Typ Max Unit Notes
Center Wavelength - RX1270 lambda c 1250 1270 1290 nm RX1270nm
Center Wavelength - RX1330 lambda c 1310 1330 1350 nm RX1330nm
Receiver Sensitivity S - - -12 dBm Note 1
LOS Assert LOS A -35 - - dBm -
LOS Deassert LOS D - - -13 dBm -
LOS Hysteresis LOSH 0.5 - 6 dB -
Receiver Overload Pov - - +1 dBm -
RX Output Differential Swing Vo 300 - 850 mVpp -

Receiver Test Condition

Receiver sensitivity is specified as the minimum average optical input power measured at an extinction ratio of 4 dB, using a 2^31-1 PRBS pattern and BER below 5E-5.

Control and Status I/O Timing

Parameter Symbol Min Max Unit
TX Disable Assert Time t_off - 100 us
TX Disable Negate Time t_on - 1 ms
Initialization Including TX Fault Reset t_init - 300 ms
TX Fault Assert Time t_fault - 100 us
TX Fault Reset Time t_reset 10 - us
LOS Assert Time t_loss_on - 100 us
LOS Deassert Time t_loss_off - 100 us
Serial ID Clock Rate f_serial_clock 100 400 kHz

Timing Conditions

TX Disable Assert: From the rising edge of TX Disable until optical output falls below 10% of nominal.

TX Disable Negate: From the falling edge of TX Disable until modulated optical output exceeds 90% of nominal.

Initialization: From power-on or negation of TX Fault using TX Disable.

TX Fault Assert: From fault occurrence to TX Fault assertion.

TX Fault Reset: Minimum time TX Disable must remain HIGH to reset TX Fault.

LOS Assert: From entering the LOS state until RX_LOS assertion.

LOS Deassert: From leaving the LOS state until RX_LOS deassertion.

The source's eighth explanatory note describes Rate Select timing rather than the Serial ID Clock Rate listed in the table. The serial clock frequency requires confirmation against the original approved design.

Pin Assignment and Description

Pin Symbol Description Note
1 VeeT Module Transmitter Ground 1
2 TX_Fault Module Transmitter Fault 2
3 TX_Disable Transmitter Disable; Turns Off Laser Output 3
4 SDA Two-Wire Serial Interface Data Line (MOD-DEF2) 4
5 SCL Two-Wire Serial Interface Clock (MOD-DEF1) 4
6 MOD_ABS Module Absent; Connected to VeeT or VeeR 5
7 RS Rate Select; Refer to Source Description 6
8 RX_LOS Receiver Loss-of-Signal Indication 2
9 VeeR Module Receiver Ground 1
10 VeeR Module Receiver Ground 1
11 VeeR Module Receiver Ground 1
12 RD- Receiver Inverted Data Output -
13 RD+ Receiver Non-Inverted Data Output -
14 VeeR Module Receiver Ground 1
15 VccR Module Receiver 3.3V Supply -
16 VccT Module Transmitter 3.3V Supply -
17 VeeT Module Transmitter Ground 1
18 TD+ Transmitter Non-Inverted Data Input -
19 TD- Transmitter Inverted Data Input -
20 VeeT Module Transmitter Ground 1

Pin Notes

VeeR and VeeT signal grounds are isolated from the module case.

TX_Fault and RX_LOS are open-collector/open-drain outputs. The host requires 4.7k-10k Ohm pull-up resistors to Host_Vcc. No module pin should exceed VccT/R + 0.5V.

TX_Disable is an open-collector/open-drain input with an internal 4.7k-10k Ohm pull-up to VccT.

SDA and SCL follow the two-wire electrical interface referenced in SFF-8472 Section 4.2.

MOD_ABS requires a 4.7k-10k Ohm pull-up to Host_Vcc on the host board.

The source references SFF-8079 and states pin 7 may be used for RS0, followed by "Not use." The same source also describes 10.3GBd/1.25GBd rate-selection behavior. This appears inconsistent with the 25.78Gbps product and requires engineering confirmation.

Mechanical Specifications

Parameter Specification
Form Factor SFP28
Host Interface Hot-Pluggable 20-Pin
Optical Interface Simplex LC
Fiber Type 9/125um Single Mode
Fiber Configuration Single-Fiber Bidirectional
Mechanical Dimensions Refer to Approved Mechanical Drawing

The supplied text includes a Mechanical Specifications section but does not provide numerical dimensions or tolerances. Insert the approved original engineering drawing here.

Product Variants & Ordering Information

Spring Optical's 25G SFP28 BiDi series includes complementary 1270nm/1330nm wavelength options in commercial and industrial temperature grades.

Model TX / RX Wavelength TX Power RX Sensitivity Distance Temperature
DPP2-2325-1CY1 TX1270 / RX1330nm -4 to +2 dBm -12 dBm 10KM 0 to +70C
DPP2-3225-1CY1 TX1330 / RX1270nm -4 to +2 dBm -12 dBm 10KM 0 to +70C
DPP2-2325-1IY1 TX1270 / RX1330nm -4 to +2 dBm -12 dBm 10KM -40 to +85C
DPP2-3225-1IY1 TX1330 / RX1270nm -4 to +2 dBm -12 dBm 10KM -40 to +85C

All four models are specified as SFP28, 25.78Gbps, DDM-enabled, RoHS compliant, and equipped with simplex LC optical interfaces.

Wavelength Pairing Requirement

A-side: TX1270nm / RX1330nm

B-side: TX1330nm / RX1270nm

A valid BiDi link requires one complementary module at each end of the same fiber.

OEM/ODM Requirements for Review

Host equipment and firmware compatibility

EEPROM or module identification requirements

Product labeling and packaging

Commercial or industrial temperature configuration

Project-specific testing and qualification

25G SFP28 BiDi Transceiver Module Applications

The 25G SFP28 BiDi optical transceiver supports single-fiber high-speed connections in compatible optical networking systems.

High-Speed Storage Area Networks: 25G-class links between compatible storage network devices.

Switch-to-Switch Interconnections: Bidirectional optical communication between network switches.

High-Speed Network Interconnects: 25.78Gbps optical links across single-mode fiber infrastructure.

Single-Fiber Optical Links: Point-to-point communication where a complementary wavelength pair is available.

Typical Network Architecture

A 25G BiDi fiber link carries both transmit and receive signals over one single-mode fiber using complementary wavelengths.

25G Switch A -> SFP28 BiDi A (TX1270 / RX1330) -> Simplex LC / One SMF (up to 10KM) -> SFP28 BiDi B (TX1330 / RX1270) -> 25G Switch B

Use one TX1270/RX1330 module and one TX1330/RX1270 module. Do not install two modules with the same wavelength configuration at opposite ends.

Engineering Selection & Installation Guidelines

1. Confirm the Complementary Wavelength Pair

The 1270nm and 1330nm variants must be paired correctly. A TX1270/RX1330 module communicates with a TX1330/RX1270 module through one single-mode fiber. Two identical wavelength variants do not form a valid bidirectional link.

2. Evaluate the Optical Power Budget

The source specifies minimum average TX power of -4 dBm and receiver sensitivity of -12 dBm.

Calculated Optical Power Budget = -4 dBm - (-12 dBm) = 8 dB

This is a nominal calculation based on the published receiver sensitivity at BER below 5E-5, not a guaranteed error-free link budget. Include fiber attenuation, connector and splice losses, test conditions, and system margin before confirming a 10KM installation.

3. Check Receiver Overload and Host Power

Receiver overload is specified as +1 dBm. Verify that the received optical level stays within the allowable receiver range.

The module uses a nominal 3.3V supply, with a specified supply current of 450mA and power dissipation of 1.5W in the recommended conditions table. Confirm host port power capacity before installation.

4. Verify Host Compatibility and Optical Handling

Confirm SFP28 interface support, EEPROM requirements, and 25.78Gbps host capability. Clean the simplex LC connector before insertion, use suitable ESD protection, and avoid looking directly into an active optical port.

Frequently Asked Questions

1. What is a 25G SFP28 BiDi transceiver module?

A 25G SFP28 BiDi transceiver is a hot-pluggable optical module that uses separate transmit and receive wavelengths to carry bidirectional data over one fiber. Spring Optical's 1270/1330nm series supports up to 25.78Gbps over a 10KM single-mode fiber link with a simplex LC connector.

2. Does the 25G BiDi module require one fiber or two?

It requires one single-mode fiber. A BiDi transceiver uses different optical wavelengths for transmission and reception over the same fiber. The two endpoints must use complementary wavelength configurations rather than identical modules, and both must be compatible with the installed fiber and host equipment.

3. How should 1270nm and 1330nm BiDi modules be paired?

Use a TX1270/RX1330 module at one endpoint and a TX1330/RX1270 module at the other endpoint. The DPP2-2325 series provides the 1270nm transmitter, while DPP2-3225 provides the 1330nm transmitter. Choose the appropriate commercial or industrial temperature variant for each installation.

4. What is the optical power budget of this 10KM transceiver?

The calculated budget is 8 dB based on minimum transmitter power of -4 dBm and receiver sensitivity of -12 dBm. The sensitivity is measured under the source's specified BER and PRBS test conditions. Actual link design must account for fiber losses, connectors, splices, and appropriate engineering margin.

5. Does the module support digital diagnostic monitoring?

Yes. It supports SFF-8472 digital diagnostic monitoring through a two-wire serial interface. Available monitoring parameters include module temperature, supply voltage, transmitter laser bias current, transmitted optical power, and received optical power. The host equipment must support the diagnostic interface to read these values.

6. What operating temperature options are available?

The commercial versions operate from 0 to +70C, and industrial versions support -40 to +85C. Both ranges are available with 1270nm or 1330nm transmitters, allowing customers to select complementary BiDi modules for the required network operating conditions.

Quality Assurance & OEM/ODM Manufacturing

Spring Optical supplies optical communication components for telecom operators, ISPs, system integrators, network equipment vendors, and distributors.

OEM/ODM support is available for host compatibility review, module identification, packaging, labeling, and project-specific qualification requirements.

Relevant Product Verification

Transmitter center wavelength and output power

Receiver sensitivity and overload performance

Optical extinction ratio and spectral characteristics

Digital diagnostic monitoring functionality

Host electrical interface verification

Commercial and industrial temperature evaluation

Wavelength pairing and link testing

Simplex LC interface and product inspection

Actual testing coverage and inspection frequency should be confirmed through the approved quality control plan.

Packing, Storage & Shipping

The specified storage temperature is -40 to +85C, with 5%-95% relative humidity under non-condensing conditions.

Protect the simplex LC optical connector from dust and physical damage. Follow ESD-safe handling procedures during storage, installation, and transportation.

Packing quantities, carton dimensions, delivery schedules, and shipping arrangements should be confirmed against the purchase order.

Related Products

Product Application
25G SFP28 LR Transceiver Module Dual-fiber 1310nm single-mode links
25G SFP28 SR Transceiver Module Short-range multimode connections
10G SFP+ BiDi Transceiver Lower-speed single-fiber optical links
100G QSFP28 LR4 Transceiver Higher-speed single-mode network links
LC Simplex Single Mode Patch Cord Single-fiber BiDi connections
Fiber Optic Patch Panel Fiber termination and distribution

Request Datasheet & Quotation

Contact Spring Optical for the 25G SFP28 BiDi Transceiver Module datasheet, compatible wavelength pair selection, OEM/ODM requirements, sample evaluation, or project quotation.

Please provide the host equipment model, required TX/RX wavelength configuration, operating temperature range, and purchase quantity.

Hot Tags: 25G SFP28 BIDI, 25G SFP28 BiDi Transceiver Module, 25G SFP28, SFP28 Transceiver, Optical Transceiver, SFP28 Transceiver Module, Optical Module, Transceiver Module, 25G Optical Transceiver, 1270/1330nm BiDi Transceiver, 25G BiDi 10KM, Single Fiber SFP28

Send Inquiry