10G SFP+ Transceiver Module 1310nm 20KM Dual Fiber LC DDM

10G SFP+ Transceiver Module 1310nm 20KM Dual Fiber LC DDM
Details:
·10.3125Gbps Data Rate & 20KM Reach - Supports 10Gbps optical transmission over single-mode fiber links up to 20KM.
·1310nm DFB Laser & Duplex LC - Separate TX and RX optical ports for dual-fiber communication.
·Industrial Temperature Support - Commercial 0 to +70°C and industrial -40 to +85°C operating case temperature options.
·Digital Diagnostic Monitoring (DDM) - Monitors TX/RX optical power, temperature, supply voltage, and laser bias current.
·Optical Receiver Performance - PIN photodetector with specified -14.4 dBm average-power receiver sensitivity.
·Low-Power SFP+ Design - Typical 800mW power consumption, all-metal housing, and SFF-8431/SFF-8472 interface compliance.
Send Inquiry
Description
Send Inquiry

Spring Optical Communication is one of the largest and best 10g sfp+ transceiver module 1310nm 20km dual fiber lc ddm manufacturers and suppliers with rich experience. Welcome to buy our high quality products or wholesale our customized 10g sfp+ transceiver module 1310nm 20km dual fiber lc ddm in stock with our factory. Also, free sample is also available if necessary.

 

The 10G SFP+ Transceiver Module is a dual-fiber optical transceiver designed for 10.3125Gbps transmission over distances up to 20KM using single-mode fiber. Featuring a 1310nm DFB laser, duplex LC interface, digital diagnostic monitoring (DDM), and commercial or industrial temperature options, it supports storage area networks, computer clusters, and compatible 10Gbps network equipment.

Product Overview

10g-sfp-plus-transceiver-1310nm-20km

Spring Optical's 10G SFP+ Transceiver Module supports 10.3125Gbps optical transmission over single-mode fiber links up to 20KM. The DPP1-3192-2XY1 series integrates a 1310nm DFB laser transmitter, PIN photodetector, and duplex LC interface for separate transmit and receive paths.

The optical module features automatic power control (APC), internally AC-coupled differential data interfaces, and digital diagnostic monitoring for TX/RX optical power, temperature, supply voltage, and laser bias current. Its all-metal housing supports EMI control and high-density SFP+ port integration.

Designed in accordance with IEEE 802.3ae 10GBASE-LR, SFF-8431, SFF-8432, and SFF-8472 specifications, the module supports compatible 10Gbps switches, storage networks, and computer cluster interconnections. Commercial and industrial temperature configurations are available for different operating environments.

Key Features & Engineering Advantages

10.3125Gbps Data Rate & 20KM Reach - Supports 10Gbps optical transmission over single-mode fiber links up to 20KM.

1310nm DFB Laser & Duplex LC - Separate TX and RX optical ports for dual-fiber communication.

Industrial Temperature Support - Commercial 0 to +70°C and industrial -40 to +85°C operating case temperature options.

Digital Diagnostic Monitoring (DDM) - Monitors TX/RX optical power, temperature, supply voltage, and laser bias current.

Optical Receiver Performance - PIN photodetector with specified -14.4 dBm average-power receiver sensitivity.

Low-Power SFP+ Design - Typical 800mW power consumption, all-metal housing, and SFF-8431/SFF-8472 interface compliance.

Technical Specifications

General Specifications

Parameter Specification
Product Series DPP1-3192-2XY1
Product Type 10G SFP+ LR Dual Fiber Transceiver
Data Rate 10.3125Gbps
Transmission Distance 20KM
Nominal TX Wavelength 1310nm
TX Wavelength Range 1260-1355nm
RX Wavelength Range 1260-1620nm
Fiber Type Single Mode Fiber
Transmission Type Dual Fiber
Optical Interface Duplex LC
Transmitter 1310nm DFB Laser
Receiver PIN Photodetector
Electrical Interface SFI, 100 Ohm Differential
Data Line Coupling Internally AC-Coupled
Digital Diagnostics SFF-8472 Rev. 10.2 DDM
Diagnostic Calibration Internal; External by Request
Power Supply 3.3V
Typical Power Consumption 800mW
Maximum Power Consumption 1000mW
Housing All-Metal
Firmware Supports Storage of Customer System Encryption Information
Optical Standard IEEE 802.3ae 10GBASE-LR
Electrical Standard SFF-8431
Mechanical Standard SFF-8432 Rev. 5.0
Diagnostic Standard SFF-8472
Environmental Compliance RoHS Compliant
Commercial Operating Temperature 0 to +70°C
Industrial Operating Temperature -40 to +85°C

Absolute Maximum Ratings

Parameter Symbol Min Max Unit
Power Supply Voltage Vcc 0 3.6 V
Storage Temperature Tc -40 85 °C
Operating Case Temperature - Commercial Tc 0 70 °C
Operating Case Temperature - Industrial TI -40 85 °C
Relative Humidity RH 5 95 %
RX Input Average Power Pmax - 0 dBm

Note: These ratings represent device damage thresholds. Exceeding any absolute maximum rating may immediately damage the module, even if other parameters remain within their recommended operating limits.

Recommended Operating Conditions

Parameter Symbol Min Typ Max Unit
Power Supply Voltage Vcc 3.135 3.3 3.465 V
Power Supply Current Icc - - 300 mA
Operating Case Temperature - Commercial TC 0 25 70 °C
Operating Case Temperature - Industrial TC -40 25 85 °C

Note: Electrical and optical characteristics apply under the recommended operating conditions unless otherwise specified.

Optical Characteristics - Transmitter

Parameter Min Max Unit
Operating Reach - 20,000 m
Center Wavelength Range 1260 1355 nm
Side Mode Suppression Ratio 30 - dB
Average Launched Power -6 2 dBm
Transmitter and Dispersion Penalty - 3.2 dB
Average Launch Power of OFF Transmitter - -30 dBm
Extinction Ratio 3.5 - dB
RIN12 OMA - -128 dB/Hz
Optical Return Loss Tolerance 12 - dB

Optical Characteristics - Receiver

Parameter Min Max Unit
Operating Wavelength Range 1260 1620 nm
Receive Overload (Average Power) - 0.5 dBm
Receiver Sensitivity (Average Power) -14.4 - dBm
Receiver Sensitivity in OMA - -12.6 dBm
Receiver Reflectance - -12 dB
Stressed Receiver Sensitivity in OMA - -10.3 dBm
Vertical Eye Closure Penalty 2.2 - dB
LOS Assert -30 - dBm
LOS Deassert - -12 dBm
LOS Hysteresis 0.5 - dB
Stressed Eye Jitter 0.3 - UIp-p
Receiver Electrical 3dB Upper Cutoff Frequency - 12.3 GHz
Receiver Power - Damage Threshold - 1.5 dBm

Optical Notes

Average optical power is measured using TIA/EIA-455-95 methods.

Receiver sensitivity is informative. Stressed receiver sensitivity is measured using a conformance test signal at BER = 1 x 10-12.

Vertical eye closure penalty and stressed eye jitter are test conditions for stressed receiver sensitivity, not required receiver characteristics.

Optical power budget is defined as the difference between receiver sensitivity and transmitter output power.

Path penalty describes the power penalty between back-to-back operation and maximum applied dispersion.

The Min/Max positions above follow the original datasheet. Parameters requiring limit-convention clarification should be verified against the approved test specification.

Digital Diagnostic Functions

Parameter Symbol Min Error Max Error Unit Notes
Temperature Monitor DMI_Temp -3 3 °C Over operating temperature
Laser Power Monitor DMI_TX -3 3 dB -
RX Power Monitor DMI_RX -3 3 dB -1 to -15 dBm range
Supply Voltage Monitor DMI_VCC -0.08 0.08 V Full operating range
Bias Current Monitor DMI_Ibias -10% 10% mA Percentage error

The module supports SFF-8472 Revision 10.2 with internal calibration. External calibration requirements can be reviewed upon request.

Electrical Characteristics

Parameter Symbol Min Typ Max Unit
Data Rate - - 10.3125 - Gbps
Power Consumption - - 800 1000 mW

Transmitter Electrical Characteristics

Parameter Symbol Min Typ Max Unit Note
Single-Ended Output Voltage Tolerance - -0.3 - 4 V -
Common Mode Voltage Tolerance - 15 - - mV -
TX Input Differential Voltage VI 180 - 800 mV -
TX Fault VoL -0.3 - 0.4 V At 0.7mA
Data-Dependent Input Jitter DDJ - - 0.1 UI -
Data Input Total Jitter TJ - - 0.28 UI -

Receiver Electrical Characteristics

Parameter Symbol Min Typ Max Unit Note
Single-Ended Output Voltage Tolerance - -0.3 - 4 V -
RX Output Differential Voltage Vo 300 - 850 mV -
RX Output Rise/Fall Time Tr/Tf 30 - - ps 20%-80%
Total Jitter TJ - - 0.7 UI -
Deterministic Jitter DJ - - 0.42 UI -

Note: Values are specified under the recommended operating conditions unless otherwise stated.

Control and Status I/O Timing

Parameter Symbol Min Max Unit
TX Disable Assert Time t_off - 10 us
TX Disable Negate Time t_on - 1 ms
Initialization Time, Including TX Fault Reset t_init - 300 ms
TX Fault Assert Time t_fault - 100 us
TX Disable Reset Time t_reset 10 - us
LOS Assert Time t_loss_on - 100 us
LOS Deassert Time t_loss_off - 100 us
Rate-Select Change Time t_ratesel - 10 us
Serial ID Clock Rate t_serial_clock - 100 kHz

Timing Conditions

TX Disable Assert: Time from rising TX Disable until optical output falls below 10% of nominal.

TX Disable Negate: Time from falling TX Disable until modulated optical output exceeds 90% of nominal.

Initialization: From power-on or negation of TX Fault using TX Disable.

TX Fault Assert: Time from fault occurrence until TX Fault assertion.

TX Disable Reset: Minimum time TX Disable must remain HIGH to reset TX Fault.

LOS Assert: Time from entering the LOS state until RX_LOS assertion.

LOS Deassert: Time from leaving the LOS state until RX_LOS deassertion.

Rate Select: Time from a Rate Select transition until receiver bandwidth meets the selected specification.

Serial ID Clock Rate: Maximum 100kHz.

Control and status timing requirements are referenced to SFF-8431.

Pin Definitions

Pin Logic Symbol Description Note
1 - VeeT Module Transmitter Ground 1
2 LVTTL-O TX_Fault Module Transmitter Fault -
3 LVTTL-I TX_Dis Transmitter Disable; Turns Off Laser -
4 LVTTL-I/O SDA Two-Wire Serial Interface Data 2
5 LVTTL-I SCL Two-Wire Serial Interface Clock 2
6 - MOD_DEF0 Module Definition, Grounded in Module -
7 LVTTL-I RS0 Receiver Rate Select -
8 LVTTL-O RX_LOS Receiver Loss of Signal, Active LOW (source wording) -
9 LVTTL-I RS1 Transmitter Rate Select, Not Used -
10 - VeeR Module Receiver Ground 1
11 - VeeR Module Receiver Ground 1
12 CML-O RD- Receiver Inverted Data Output -
13 CML-O RD+ Receiver Data Output, Not Used (source wording) -
14 - VeeR Module Receiver Ground 1
15 - VccR Module Receiver 3.3V Supply -
16 - VccT Module Receiver 3.3V Supply (source wording) -
17 - VeeT Module Transmitter Ground 1
18 CML-I TD+ Transmitter Non-Inverted Data Input -
19 CML-I TD- Transmitter Inverted Data Input -
20 - VeeT Module Transmitter Ground 1

Pin Notes

Module ground pins are electrically isolated from the module case.

SDA and SCL require 4.7k-10k Ohm host pull-up resistors to a supply between 3.15V and 3.45V.

Transmitter and Receiver Architecture

Transmitter

The 1310nm DFB transmitter converts serial 10Gbps CML electrical data into optical signals. An automatic power control (APC) loop regulates optical output across supply voltage and temperature variations.

TX Disable HIGH or open: Laser disabled.

TX Disable LOW: Normal transmission.

TX Disable pull-up: 4.7k-10k Ohms to VccT.

TX Fault HIGH: Laser operation or safety-related fault indication.

TX Fault pull-up: 4.7k-10k Ohms to Vcc_Host.

Receiver

The PIN receiver converts incoming optical data into serial PECL/CML electrical signals.

RX_LOS HIGH indicates insufficient received optical power according to the functional description.

RX_LOS is an open-drain/open-collector output.

Host pull-up: 4.7k-10k Ohms to Vcc_Host, or appropriate active termination.

LOS may indicate disconnected fiber, broken fiber, or an unavailable remote transmitter.

Electrical Integration

TX input and RX output differential impedance: 100 Ohms.

Data lines are internally AC-coupled.

Differential termination is provided to reduce common-mode conversion and EMI.

SFI routing guidance: approximately 200mm on improved FR4 or 150mm on standard FR4 with one connector.

Supply filtering is recommended for both transmitter and receiver.

Mechanical Specifications

Parameter Specification
Form Factor SFP+
Mechanical Standard SFF-8432 Rev. 5.0
Optical Interface Duplex LC
Host Electrical Interface SFP+
Housing All-Metal
Fiber Configuration Dual Fiber

The module is specified as compliant with SFF-8432 Revision 5.0. Exact mechanical dimensions should follow the original approved engineering drawing.

ESD and Laser Safety

ESD Protection

ESD threshold: 2kV for electrical input pins.

Test methods: MIL-STD-883 Method 3015.4 and JESD22-A114-A (HBM).

Supplied in ESD-protective packaging.

Handle only in an ESD-protected environment.

Laser Safety

Class 1 Laser Product.

IEC 60825-1:1993 + A1:1997 + A2:2001.

Compliance stated with 21 CFR 1040.10 and 1040.11, except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.

Product Variants & Ordering Information

The DPP1-3192 series provides two 1310nm 20KM dual-fiber SFP+ models with commercial and industrial operating temperature options.

Model Data Rate Wavelength Distance Interface Temperature
DPP1-3192-2CY1W 10.3125Gbps 1310nm 20KM Duplex LC 0 to +70°C
DPP1-3192-2IY1W 10.3125Gbps 1310nm 20KM Duplex LC -40 to +85°C

OEM/ODM Options for Technical Review

Host switch compatibility and EEPROM coding

Customer system identification and firmware requirements

Product labeling and packaging customization

Commercial or industrial temperature configuration

Project-specific electrical and optical requirements

Customized configurations require engineering review and sample qualification.

10G SFP+ Transceiver Module Applications

The 10G SFP+ Transceiver Module supports high-speed 10.3125Gbps optical interconnections over up to 20KM of single-mode fiber.

Storage Area Networks: Optical links between compatible high-speed storage networking devices.

Computer Cluster Networks: 10Gbps interconnections between cluster switches and computing equipment.

High-Speed Data Transmission: Point-to-point dual-fiber links between network locations.

Enterprise and Telecom Networks: 10Gbps optical uplinks between compatible switches, routers, and aggregation equipment.

Typical Network Architecture

The 10G SFP+ optical transceiver uses two separate fibers for TX and RX communication between compatible network devices.

Core Switch -> 10G SFP+ LR Module -> Duplex LC Patch Cord -> Dual Single Mode Fiber Link (up to 20KM) -> Remote 10G SFP+ LR Module -> Access / Aggregation Switch

Each transmitter must connect to the receiver at the opposite endpoint. Both modules must support compatible optical wavelengths and link budgets.

Engineering Selection & Installation Guidelines

1. Verify Dual-Fiber Polarity

This SFP+ transceiver uses two fibers, unlike a single-fiber BiDi module. Connect TX at one endpoint to RX at the opposite endpoint, and vice versa. Confirm that both modules support the required operating wavelengths.

2. Calculate the Optical Link Budget

For the specified 1310nm optical values:

Minimum TX Power = -6 dBm

Receiver Sensitivity = -14.4 dBm

Optical Power Budget = -6 dBm - (-14.4 dBm) = 8.4 dB

The calculated budget is 8.4 dB before fiber attenuation, connector losses, splice losses, dispersion penalties, and engineering margin.

The specified maximum transmitter and dispersion penalty is 3.2 dB. Verify the full link budget and ensure the received optical power does not exceed the 0.5 dBm receiver overload specification.

3. Confirm Host Compatibility

Verify that the host supports a 10.3125Gbps SFP+ interface, SFF-8431 electrical requirements, 3.3V power, and the required EEPROM identification. Select the correct operating temperature grade before ordering.

4. Follow Optical Cleaning and ESD Procedures

Inspect and clean duplex LC connectors before installation. Keep unused ports protected with dust caps, handle modules in an ESD-protected environment, and never look directly into an active optical port.

Frequently Asked Questions

1. What is a 10G SFP+ transceiver module?

A 10G SFP+ transceiver module converts high-speed electrical signals into optical signals for fiber transmission. Spring Optical's 1310nm dual-fiber model supports 10.3125Gbps data transmission over distances up to 20KM using single-mode fiber and a duplex LC optical interface.

2. Is this a dual-fiber or BiDi SFP+ module?

This is a dual-fiber SFP+ module. It uses separate optical fibers for transmitting and receiving signals. Unlike a single-fiber BiDi transceiver, it does not require complementary 1270nm/1330nm wavelength modules at opposite endpoints.

3. What is the optical power budget for the 20KM link?

The calculated optical power budget is 8.4 dB based on -6 dBm minimum transmitter power and -14.4 dBm receiver sensitivity. Actual link design must account for fiber attenuation, connector losses, splice losses, dispersion penalties, and engineering margin.

4. Can this module work with Cisco or other 10G switches?

Compatibility depends on the host switch model, firmware, SFP+ interface, and EEPROM requirements. The module follows SFF-8431 electrical specifications, but vendor-specific acceptance must be verified. Spring Optical can review host compatibility and coding requirements during OEM/ODM qualification.

5. What is the difference between commercial and industrial versions?

The commercial model operates from 0 to +70°C, while the industrial model supports -40 to +85°C. Both provide 10.3125Gbps transmission, a nominal 1310nm DFB transmitter, 20KM reach, and duplex LC connectivity.

6. Does the optical module support digital diagnostic monitoring?

Yes. The module supports SFF-8472 Revision 10.2 digital diagnostic monitoring with internal calibration. It reports temperature, supply voltage, transmitted and received optical power, and laser bias current. Host equipment must support the management interface to access this information.

Quality Assurance & OEM/ODM Manufacturing

Shenzhen Spring Optical Communication Co., Ltd. supplies optical communication components for telecom operators, ISPs, system integrators, and distributors.

Spring Optical's stated manufacturing capabilities include optical component assembly, product testing, quality management, and OEM/ODM support.

Relevant Product Verification

TX optical power and wavelength measurement

Receiver sensitivity and overload verification

Optical signal and jitter evaluation

DDM and EEPROM functional testing

Commercial and industrial temperature evaluation

Host equipment compatibility verification

Mechanical appearance and LC interface inspection

Actual production test coverage and inspection frequency should be confirmed against the approved product quality plan.

OEM/ODM services include technical review of host coding, customer product identification, packaging, and project-specific requirements.

Packing, Storage & Shipping

The optical transceiver is supplied in ESD-protective packaging and should be handled in an ESD-protected environment.

Specified storage temperature is -40 to +85°C, with a relative humidity range of 5% to 95% under the absolute maximum ratings.

Protect the optical interface against dust and mechanical damage. Packing quantities, carton dimensions, delivery schedules, and shipping arrangements are confirmed according to project requirements.

Related Products

Product Application
10G SFP+ BiDi Transceiver Single-fiber alternative for compatible 10Gbps links
10G SFP+ SR Transceiver Short-range multimode optical connections
25G SFP28 Transceiver Module Higher-speed equipment interconnections
OS2 Single Mode Fiber Cable Long-distance optical transmission
LC Duplex Fiber Patch Cord Connection between SFP+ modules and fiber distribution equipment
Fiber Optic Patch Panel Fiber termination, routing, and cable management

Request Datasheet & Quotation

Contact Spring Optical for the 10G SFP+ Transceiver Module datasheet, host compatibility verification, OEM/ODM options, sample evaluation, or project quotation.

Please provide the host switch model, required operating temperature grade, quantity, and compatibility coding requirements.

Hot Tags: 10G SFP+, SFP+ Transceiver, Optical Module, SFP Transceiver, Optical Transceiver, SFP Transceiver Module, SFP Module, Transceiver Module, Fiber Transceiver

Send Inquiry