Spring Optical Communication is one of the largest and best 10g sfp+ transceiver module 1310nm 20km dual fiber lc ddm manufacturers and suppliers with rich experience. Welcome to buy our high quality products or wholesale our customized 10g sfp+ transceiver module 1310nm 20km dual fiber lc ddm in stock with our factory. Also, free sample is also available if necessary.
The 10G SFP+ Transceiver Module is a dual-fiber optical transceiver designed for 10.3125Gbps transmission over distances up to 20KM using single-mode fiber. Featuring a 1310nm DFB laser, duplex LC interface, digital diagnostic monitoring (DDM), and commercial or industrial temperature options, it supports storage area networks, computer clusters, and compatible 10Gbps network equipment.
Product Overview

Spring Optical's 10G SFP+ Transceiver Module supports 10.3125Gbps optical transmission over single-mode fiber links up to 20KM. The DPP1-3192-2XY1 series integrates a 1310nm DFB laser transmitter, PIN photodetector, and duplex LC interface for separate transmit and receive paths.
The optical module features automatic power control (APC), internally AC-coupled differential data interfaces, and digital diagnostic monitoring for TX/RX optical power, temperature, supply voltage, and laser bias current. Its all-metal housing supports EMI control and high-density SFP+ port integration.
Designed in accordance with IEEE 802.3ae 10GBASE-LR, SFF-8431, SFF-8432, and SFF-8472 specifications, the module supports compatible 10Gbps switches, storage networks, and computer cluster interconnections. Commercial and industrial temperature configurations are available for different operating environments.
Key Features & Engineering Advantages
10.3125Gbps Data Rate & 20KM Reach - Supports 10Gbps optical transmission over single-mode fiber links up to 20KM.
1310nm DFB Laser & Duplex LC - Separate TX and RX optical ports for dual-fiber communication.
Industrial Temperature Support - Commercial 0 to +70°C and industrial -40 to +85°C operating case temperature options.
Digital Diagnostic Monitoring (DDM) - Monitors TX/RX optical power, temperature, supply voltage, and laser bias current.
Optical Receiver Performance - PIN photodetector with specified -14.4 dBm average-power receiver sensitivity.
Low-Power SFP+ Design - Typical 800mW power consumption, all-metal housing, and SFF-8431/SFF-8472 interface compliance.
Technical Specifications
General Specifications
| Parameter | Specification |
|---|---|
| Product Series | DPP1-3192-2XY1 |
| Product Type | 10G SFP+ LR Dual Fiber Transceiver |
| Data Rate | 10.3125Gbps |
| Transmission Distance | 20KM |
| Nominal TX Wavelength | 1310nm |
| TX Wavelength Range | 1260-1355nm |
| RX Wavelength Range | 1260-1620nm |
| Fiber Type | Single Mode Fiber |
| Transmission Type | Dual Fiber |
| Optical Interface | Duplex LC |
| Transmitter | 1310nm DFB Laser |
| Receiver | PIN Photodetector |
| Electrical Interface | SFI, 100 Ohm Differential |
| Data Line Coupling | Internally AC-Coupled |
| Digital Diagnostics | SFF-8472 Rev. 10.2 DDM |
| Diagnostic Calibration | Internal; External by Request |
| Power Supply | 3.3V |
| Typical Power Consumption | 800mW |
| Maximum Power Consumption | 1000mW |
| Housing | All-Metal |
| Firmware | Supports Storage of Customer System Encryption Information |
| Optical Standard | IEEE 802.3ae 10GBASE-LR |
| Electrical Standard | SFF-8431 |
| Mechanical Standard | SFF-8432 Rev. 5.0 |
| Diagnostic Standard | SFF-8472 |
| Environmental Compliance | RoHS Compliant |
| Commercial Operating Temperature | 0 to +70°C |
| Industrial Operating Temperature | -40 to +85°C |
Absolute Maximum Ratings
| Parameter | Symbol | Min | Max | Unit |
|---|---|---|---|---|
| Power Supply Voltage | Vcc | 0 | 3.6 | V |
| Storage Temperature | Tc | -40 | 85 | °C |
| Operating Case Temperature - Commercial | Tc | 0 | 70 | °C |
| Operating Case Temperature - Industrial | TI | -40 | 85 | °C |
| Relative Humidity | RH | 5 | 95 | % |
| RX Input Average Power | Pmax | - | 0 | dBm |
Note: These ratings represent device damage thresholds. Exceeding any absolute maximum rating may immediately damage the module, even if other parameters remain within their recommended operating limits.
Recommended Operating Conditions
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Power Supply Voltage | Vcc | 3.135 | 3.3 | 3.465 | V |
| Power Supply Current | Icc | - | - | 300 | mA |
| Operating Case Temperature - Commercial | TC | 0 | 25 | 70 | °C |
| Operating Case Temperature - Industrial | TC | -40 | 25 | 85 | °C |
Note: Electrical and optical characteristics apply under the recommended operating conditions unless otherwise specified.
Optical Characteristics - Transmitter
| Parameter | Min | Max | Unit |
|---|---|---|---|
| Operating Reach | - | 20,000 | m |
| Center Wavelength Range | 1260 | 1355 | nm |
| Side Mode Suppression Ratio | 30 | - | dB |
| Average Launched Power | -6 | 2 | dBm |
| Transmitter and Dispersion Penalty | - | 3.2 | dB |
| Average Launch Power of OFF Transmitter | - | -30 | dBm |
| Extinction Ratio | 3.5 | - | dB |
| RIN12 OMA | - | -128 | dB/Hz |
| Optical Return Loss Tolerance | 12 | - | dB |
Optical Characteristics - Receiver
| Parameter | Min | Max | Unit |
|---|---|---|---|
| Operating Wavelength Range | 1260 | 1620 | nm |
| Receive Overload (Average Power) | - | 0.5 | dBm |
| Receiver Sensitivity (Average Power) | -14.4 | - | dBm |
| Receiver Sensitivity in OMA | - | -12.6 | dBm |
| Receiver Reflectance | - | -12 | dB |
| Stressed Receiver Sensitivity in OMA | - | -10.3 | dBm |
| Vertical Eye Closure Penalty | 2.2 | - | dB |
| LOS Assert | -30 | - | dBm |
| LOS Deassert | - | -12 | dBm |
| LOS Hysteresis | 0.5 | - | dB |
| Stressed Eye Jitter | 0.3 | - | UIp-p |
| Receiver Electrical 3dB Upper Cutoff Frequency | - | 12.3 | GHz |
| Receiver Power - Damage Threshold | - | 1.5 | dBm |
Optical Notes
Average optical power is measured using TIA/EIA-455-95 methods.
Receiver sensitivity is informative. Stressed receiver sensitivity is measured using a conformance test signal at BER = 1 x 10-12.
Vertical eye closure penalty and stressed eye jitter are test conditions for stressed receiver sensitivity, not required receiver characteristics.
Optical power budget is defined as the difference between receiver sensitivity and transmitter output power.
Path penalty describes the power penalty between back-to-back operation and maximum applied dispersion.
The Min/Max positions above follow the original datasheet. Parameters requiring limit-convention clarification should be verified against the approved test specification.
Digital Diagnostic Functions
| Parameter | Symbol | Min Error | Max Error | Unit | Notes |
|---|---|---|---|---|---|
| Temperature Monitor | DMI_Temp | -3 | 3 | °C | Over operating temperature |
| Laser Power Monitor | DMI_TX | -3 | 3 | dB | - |
| RX Power Monitor | DMI_RX | -3 | 3 | dB | -1 to -15 dBm range |
| Supply Voltage Monitor | DMI_VCC | -0.08 | 0.08 | V | Full operating range |
| Bias Current Monitor | DMI_Ibias | -10% | 10% | mA | Percentage error |
The module supports SFF-8472 Revision 10.2 with internal calibration. External calibration requirements can be reviewed upon request.
Electrical Characteristics
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Data Rate | - | - | 10.3125 | - | Gbps |
| Power Consumption | - | - | 800 | 1000 | mW |
Transmitter Electrical Characteristics
| Parameter | Symbol | Min | Typ | Max | Unit | Note |
|---|---|---|---|---|---|---|
| Single-Ended Output Voltage Tolerance | - | -0.3 | - | 4 | V | - |
| Common Mode Voltage Tolerance | - | 15 | - | - | mV | - |
| TX Input Differential Voltage | VI | 180 | - | 800 | mV | - |
| TX Fault | VoL | -0.3 | - | 0.4 | V | At 0.7mA |
| Data-Dependent Input Jitter | DDJ | - | - | 0.1 | UI | - |
| Data Input Total Jitter | TJ | - | - | 0.28 | UI | - |
Receiver Electrical Characteristics
| Parameter | Symbol | Min | Typ | Max | Unit | Note |
|---|---|---|---|---|---|---|
| Single-Ended Output Voltage Tolerance | - | -0.3 | - | 4 | V | - |
| RX Output Differential Voltage | Vo | 300 | - | 850 | mV | - |
| RX Output Rise/Fall Time | Tr/Tf | 30 | - | - | ps | 20%-80% |
| Total Jitter | TJ | - | - | 0.7 | UI | - |
| Deterministic Jitter | DJ | - | - | 0.42 | UI | - |
Note: Values are specified under the recommended operating conditions unless otherwise stated.
Control and Status I/O Timing
| Parameter | Symbol | Min | Max | Unit |
|---|---|---|---|---|
| TX Disable Assert Time | t_off | - | 10 | us |
| TX Disable Negate Time | t_on | - | 1 | ms |
| Initialization Time, Including TX Fault Reset | t_init | - | 300 | ms |
| TX Fault Assert Time | t_fault | - | 100 | us |
| TX Disable Reset Time | t_reset | 10 | - | us |
| LOS Assert Time | t_loss_on | - | 100 | us |
| LOS Deassert Time | t_loss_off | - | 100 | us |
| Rate-Select Change Time | t_ratesel | - | 10 | us |
| Serial ID Clock Rate | t_serial_clock | - | 100 | kHz |
Timing Conditions
TX Disable Assert: Time from rising TX Disable until optical output falls below 10% of nominal.
TX Disable Negate: Time from falling TX Disable until modulated optical output exceeds 90% of nominal.
Initialization: From power-on or negation of TX Fault using TX Disable.
TX Fault Assert: Time from fault occurrence until TX Fault assertion.
TX Disable Reset: Minimum time TX Disable must remain HIGH to reset TX Fault.
LOS Assert: Time from entering the LOS state until RX_LOS assertion.
LOS Deassert: Time from leaving the LOS state until RX_LOS deassertion.
Rate Select: Time from a Rate Select transition until receiver bandwidth meets the selected specification.
Serial ID Clock Rate: Maximum 100kHz.
Control and status timing requirements are referenced to SFF-8431.
Pin Definitions
| Pin | Logic | Symbol | Description | Note |
|---|---|---|---|---|
| 1 | - | VeeT | Module Transmitter Ground | 1 |
| 2 | LVTTL-O | TX_Fault | Module Transmitter Fault | - |
| 3 | LVTTL-I | TX_Dis | Transmitter Disable; Turns Off Laser | - |
| 4 | LVTTL-I/O | SDA | Two-Wire Serial Interface Data | 2 |
| 5 | LVTTL-I | SCL | Two-Wire Serial Interface Clock | 2 |
| 6 | - | MOD_DEF0 | Module Definition, Grounded in Module | - |
| 7 | LVTTL-I | RS0 | Receiver Rate Select | - |
| 8 | LVTTL-O | RX_LOS | Receiver Loss of Signal, Active LOW (source wording) | - |
| 9 | LVTTL-I | RS1 | Transmitter Rate Select, Not Used | - |
| 10 | - | VeeR | Module Receiver Ground | 1 |
| 11 | - | VeeR | Module Receiver Ground | 1 |
| 12 | CML-O | RD- | Receiver Inverted Data Output | - |
| 13 | CML-O | RD+ | Receiver Data Output, Not Used (source wording) | - |
| 14 | - | VeeR | Module Receiver Ground | 1 |
| 15 | - | VccR | Module Receiver 3.3V Supply | - |
| 16 | - | VccT | Module Receiver 3.3V Supply (source wording) | - |
| 17 | - | VeeT | Module Transmitter Ground | 1 |
| 18 | CML-I | TD+ | Transmitter Non-Inverted Data Input | - |
| 19 | CML-I | TD- | Transmitter Inverted Data Input | - |
| 20 | - | VeeT | Module Transmitter Ground | 1 |
Pin Notes
Module ground pins are electrically isolated from the module case.
SDA and SCL require 4.7k-10k Ohm host pull-up resistors to a supply between 3.15V and 3.45V.
Transmitter and Receiver Architecture
Transmitter
The 1310nm DFB transmitter converts serial 10Gbps CML electrical data into optical signals. An automatic power control (APC) loop regulates optical output across supply voltage and temperature variations.
TX Disable HIGH or open: Laser disabled.
TX Disable LOW: Normal transmission.
TX Disable pull-up: 4.7k-10k Ohms to VccT.
TX Fault HIGH: Laser operation or safety-related fault indication.
TX Fault pull-up: 4.7k-10k Ohms to Vcc_Host.
Receiver
The PIN receiver converts incoming optical data into serial PECL/CML electrical signals.
RX_LOS HIGH indicates insufficient received optical power according to the functional description.
RX_LOS is an open-drain/open-collector output.
Host pull-up: 4.7k-10k Ohms to Vcc_Host, or appropriate active termination.
LOS may indicate disconnected fiber, broken fiber, or an unavailable remote transmitter.
Electrical Integration
TX input and RX output differential impedance: 100 Ohms.
Data lines are internally AC-coupled.
Differential termination is provided to reduce common-mode conversion and EMI.
SFI routing guidance: approximately 200mm on improved FR4 or 150mm on standard FR4 with one connector.
Supply filtering is recommended for both transmitter and receiver.
Mechanical Specifications
| Parameter | Specification |
|---|---|
| Form Factor | SFP+ |
| Mechanical Standard | SFF-8432 Rev. 5.0 |
| Optical Interface | Duplex LC |
| Host Electrical Interface | SFP+ |
| Housing | All-Metal |
| Fiber Configuration | Dual Fiber |
The module is specified as compliant with SFF-8432 Revision 5.0. Exact mechanical dimensions should follow the original approved engineering drawing.
ESD and Laser Safety
ESD Protection
ESD threshold: 2kV for electrical input pins.
Test methods: MIL-STD-883 Method 3015.4 and JESD22-A114-A (HBM).
Supplied in ESD-protective packaging.
Handle only in an ESD-protected environment.
Laser Safety
Class 1 Laser Product.
IEC 60825-1:1993 + A1:1997 + A2:2001.
Compliance stated with 21 CFR 1040.10 and 1040.11, except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.
Product Variants & Ordering Information
The DPP1-3192 series provides two 1310nm 20KM dual-fiber SFP+ models with commercial and industrial operating temperature options.
| Model | Data Rate | Wavelength | Distance | Interface | Temperature |
|---|---|---|---|---|---|
| DPP1-3192-2CY1W | 10.3125Gbps | 1310nm | 20KM | Duplex LC | 0 to +70°C |
| DPP1-3192-2IY1W | 10.3125Gbps | 1310nm | 20KM | Duplex LC | -40 to +85°C |
OEM/ODM Options for Technical Review
Host switch compatibility and EEPROM coding
Customer system identification and firmware requirements
Product labeling and packaging customization
Commercial or industrial temperature configuration
Project-specific electrical and optical requirements
Customized configurations require engineering review and sample qualification.
10G SFP+ Transceiver Module Applications
The 10G SFP+ Transceiver Module supports high-speed 10.3125Gbps optical interconnections over up to 20KM of single-mode fiber.
Storage Area Networks: Optical links between compatible high-speed storage networking devices.
Computer Cluster Networks: 10Gbps interconnections between cluster switches and computing equipment.
High-Speed Data Transmission: Point-to-point dual-fiber links between network locations.
Enterprise and Telecom Networks: 10Gbps optical uplinks between compatible switches, routers, and aggregation equipment.
Typical Network Architecture
The 10G SFP+ optical transceiver uses two separate fibers for TX and RX communication between compatible network devices.
Core Switch -> 10G SFP+ LR Module -> Duplex LC Patch Cord -> Dual Single Mode Fiber Link (up to 20KM) -> Remote 10G SFP+ LR Module -> Access / Aggregation Switch
Each transmitter must connect to the receiver at the opposite endpoint. Both modules must support compatible optical wavelengths and link budgets.
Engineering Selection & Installation Guidelines
1. Verify Dual-Fiber Polarity
This SFP+ transceiver uses two fibers, unlike a single-fiber BiDi module. Connect TX at one endpoint to RX at the opposite endpoint, and vice versa. Confirm that both modules support the required operating wavelengths.
2. Calculate the Optical Link Budget
For the specified 1310nm optical values:
Minimum TX Power = -6 dBm
Receiver Sensitivity = -14.4 dBm
Optical Power Budget = -6 dBm - (-14.4 dBm) = 8.4 dB
The calculated budget is 8.4 dB before fiber attenuation, connector losses, splice losses, dispersion penalties, and engineering margin.
The specified maximum transmitter and dispersion penalty is 3.2 dB. Verify the full link budget and ensure the received optical power does not exceed the 0.5 dBm receiver overload specification.
3. Confirm Host Compatibility
Verify that the host supports a 10.3125Gbps SFP+ interface, SFF-8431 electrical requirements, 3.3V power, and the required EEPROM identification. Select the correct operating temperature grade before ordering.
4. Follow Optical Cleaning and ESD Procedures
Inspect and clean duplex LC connectors before installation. Keep unused ports protected with dust caps, handle modules in an ESD-protected environment, and never look directly into an active optical port.
Frequently Asked Questions
1. What is a 10G SFP+ transceiver module?
A 10G SFP+ transceiver module converts high-speed electrical signals into optical signals for fiber transmission. Spring Optical's 1310nm dual-fiber model supports 10.3125Gbps data transmission over distances up to 20KM using single-mode fiber and a duplex LC optical interface.
2. Is this a dual-fiber or BiDi SFP+ module?
This is a dual-fiber SFP+ module. It uses separate optical fibers for transmitting and receiving signals. Unlike a single-fiber BiDi transceiver, it does not require complementary 1270nm/1330nm wavelength modules at opposite endpoints.
3. What is the optical power budget for the 20KM link?
The calculated optical power budget is 8.4 dB based on -6 dBm minimum transmitter power and -14.4 dBm receiver sensitivity. Actual link design must account for fiber attenuation, connector losses, splice losses, dispersion penalties, and engineering margin.
4. Can this module work with Cisco or other 10G switches?
Compatibility depends on the host switch model, firmware, SFP+ interface, and EEPROM requirements. The module follows SFF-8431 electrical specifications, but vendor-specific acceptance must be verified. Spring Optical can review host compatibility and coding requirements during OEM/ODM qualification.
5. What is the difference between commercial and industrial versions?
The commercial model operates from 0 to +70°C, while the industrial model supports -40 to +85°C. Both provide 10.3125Gbps transmission, a nominal 1310nm DFB transmitter, 20KM reach, and duplex LC connectivity.
6. Does the optical module support digital diagnostic monitoring?
Yes. The module supports SFF-8472 Revision 10.2 digital diagnostic monitoring with internal calibration. It reports temperature, supply voltage, transmitted and received optical power, and laser bias current. Host equipment must support the management interface to access this information.
Quality Assurance & OEM/ODM Manufacturing
Shenzhen Spring Optical Communication Co., Ltd. supplies optical communication components for telecom operators, ISPs, system integrators, and distributors.
Spring Optical's stated manufacturing capabilities include optical component assembly, product testing, quality management, and OEM/ODM support.
Relevant Product Verification
TX optical power and wavelength measurement
Receiver sensitivity and overload verification
Optical signal and jitter evaluation
DDM and EEPROM functional testing
Commercial and industrial temperature evaluation
Host equipment compatibility verification
Mechanical appearance and LC interface inspection
Actual production test coverage and inspection frequency should be confirmed against the approved product quality plan.
OEM/ODM services include technical review of host coding, customer product identification, packaging, and project-specific requirements.
Packing, Storage & Shipping
The optical transceiver is supplied in ESD-protective packaging and should be handled in an ESD-protected environment.
Specified storage temperature is -40 to +85°C, with a relative humidity range of 5% to 95% under the absolute maximum ratings.
Protect the optical interface against dust and mechanical damage. Packing quantities, carton dimensions, delivery schedules, and shipping arrangements are confirmed according to project requirements.
Related Products
| Product | Application |
|---|---|
| 10G SFP+ BiDi Transceiver | Single-fiber alternative for compatible 10Gbps links |
| 10G SFP+ SR Transceiver | Short-range multimode optical connections |
| 25G SFP28 Transceiver Module | Higher-speed equipment interconnections |
| OS2 Single Mode Fiber Cable | Long-distance optical transmission |
| LC Duplex Fiber Patch Cord | Connection between SFP+ modules and fiber distribution equipment |
| Fiber Optic Patch Panel | Fiber termination, routing, and cable management |
Request Datasheet & Quotation
Contact Spring Optical for the 10G SFP+ Transceiver Module datasheet, host compatibility verification, OEM/ODM options, sample evaluation, or project quotation.
Please provide the host switch model, required operating temperature grade, quantity, and compatibility coding requirements.
Hot Tags: 10G SFP+, SFP+ Transceiver, Optical Module, SFP Transceiver, Optical Transceiver, SFP Transceiver Module, SFP Module, Transceiver Module, Fiber Transceiver