Spring Optical Communication is one of the largest and best 1.25g bidi sfp transceiver module, 20km smf, 1310nm/1550nm, lc/sc manufacturers and suppliers with rich experience. Welcome to buy our high quality products or wholesale our customized 1.25g bidi sfp transceiver module, 20km smf, 1310nm/1550nm, lc/sc in stock with our factory. Also, free sample is also available if necessary.
The Spring Optical 1.25G BiDi SFP is a hot-pluggable single-fiber bidirectional optical transceiver module engineered for 1.25Gbps data transmission up to 20km over 9/125μm single-mode fiber (SMF). Available with simplex LC or SC interfaces, SFF-8472 Digital Diagnostic Monitoring (DDM), and Commercial, Extended, or Industrial operating temperature ratings, it supports Ethernet, SONET/SDH, switch/router, and FTTx optical links.
Product Overview

The Spring Optical 1.25G BiDi SFP transceiver (DFP2-XX24-2XYXX Series V0.3) is a bidirectional single-mode optical transceiver module designed to carry simultaneous transmit and receive traffic at 1.25Gbps over a single strand of 9/125μm SMF up to 20km. Each transceiver module integrates three core functional blocks inside a low-EMI metal housing: an uncooled MQW/DFB laser transmitter operating at 1310nm or 1550nm, a hermetically packaged InGaAs PIN-TIA photodiode receiver, and a 2-wire serial CMOS EEPROM Digital Diagnostic Monitoring Interface (DDMI).
Deployed across Fast/Gigabit Ethernet links, ATM/SONET/SDH transmission systems, network switches, routers, and optical access networks, this 1.25G BiDi SFP module addresses fiber strand shortages and outside-plant cabling constraints. By pairing 1310nm and 1550nm optical wavelengths over one single-mode fiber instead of requiring two separate strands, network operators reduce fiber core usage and patch panel port density requirements by up to 50%.
The transceiver series is compliant with SFP MSA (INF-8074i), SFF-8472, ITU-T G.957, and IEC 825 / CDRH Class 1 laser eye safety standards, and is certified RoHS compliant and lead-free. Offered with simplex LC or SC optical connectors and operating case temperature ranges of 0°C to +70°C, -20°C to +85°C, and -40°C to +85°C, it provides consistent link performance across indoor equipment racks and unheated outdoor cabinets.
Key Features & Engineering Advantages
Single-Fiber 20km Bidirectional Link: The 1.25G BiDi SFP transmits and receives 1250 Mbps signals over a single 9/125μm SMF strand up to 20km using paired 1310nm/1550nm wavelengths, cutting single-mode fiber strand consumption in half.
Simplex LC or SC Connector Options: Available as a BiDi SFP with simplex LC or SC optical interfaces, enabling direct connection to existing optical patch panels, switches, and media converters without extra adapter jumpers.
Three Case Temperature Grades: Supports Standard/Commercial (0°C to +70°C), Extended (-20°C to +85°C), and Industrial (-40°C to +85°C) operating temperatures to match controlled server rooms or harsh outdoor enclosures.
SFF-8472 Digital Diagnostic Monitoring: Integrated 2-wire serial CMOS EEPROM (FT24C02A protocol, address A2h) reports real-time TX/RX optical power, laser bias current, supply voltage, and temperature to simplify remote link diagnostics and cut truck rolls.
PIN-TIA Receiver & Stabilized Laser: Combines an uncooled MQW/DFB laser diode (with APC and temperature compensation) and a hermetic InGaAs PIN-TIA receiver with -24 dBm minimum sensitivity and low-pass filtering for clean signal integrity.
Standard +3.3V Interface & Low-EMI Metal Shell: Runs on a single +3.3V supply with AC-coupled 100Ω CML/PECL differential I/O, LVTTL control/alarm pins, and a metal enclosure that lowers EMI in dense switch line cards.
Technical Specifications
The Spring Optical 1.25G BiDi SFP transceiver series (DFP2-XX24-2XYXX V0.3) meets the operating, optical, electrical, diagnostic, and pinout specifications detailed below.
1. General & Mechanical Specifications
| Parameter | Specification |
| Series / Version | DFP2-XX24-2XYXX Series V0.3 |
| Form Factor | Hot-Pluggable SFP Footprint |
| Data Rate | 1.25 Gbps (1250 Mbps nominal; AC-coupled receiver path supports 100Mb/s–200Mb/s without significant distortion) |
| Transmission Distance | Up to 20 km on 9/125μm Single-Mode Fiber (SMF) |
| Wavelengths | 1310nm or 1550nm nominal (paired TX/RX wavelengths) |
| Optical Interface | Simplex LC or Simplex SC |
| Optical Components | Uncooled MQW / DFB Laser Diode + Hermetic InGaAs PIN-TIA Photodiode Receiver + DDMI EEPROM |
| Diagnostic Interface | Digital Diagnostic Monitoring Interface (SFF-8472, 2-wire serial CMOS EEPROM FT24C02A, address A2h) |
| Power Supply | Single +3.3V |
| Differential Data I/O | CML / PECL Differential Inputs and Outputs |
| Status / Control Output | LVTTL Signal Detection / LOS Output, LVTTL TX-Disable Input, TX-Fault Output |
| Enclosure | Metal Enclosure for Lower EMI |
| Laser Safety & Compliance | Compliant with SFP MSA (INF-8074i), SFF-8472, ITU-T G.957, IEC 825 / CDRH Class 1; Certified RoHS & Lead-Free |
2. Absolute Maximum Ratings
Note: Exceeding any of these values may immediately damage the device.
| Parameter | Symbol | Min | Max | Unit | Notes |
| Storage Temperature | Ts | -40 | +85 | °C | Exceeding may immediately damage device |
| Operating Temperature | Tc | 0 | +70 | °C | Standard grade |
| Operating Temperature | Tc | -20 | +85 | °C | Extended grade |
| Operating Temperature | Tc | -40 | +85 | °C | Industrial grade |
| Input Voltage | - | GND | Vcc | V | Exceeding may immediately damage device |
| Power Supply Voltage | Vcc - VEE | 0 | +3.6 | V | Exceeding may immediately damage device |
3. Recommended Operating Conditions
| Parameter | Symbol | Min | Typ | Max | Unit |
| Storage Temperature | Ts | -40 | - | +85 | °C |
| Operating Case Temperature | Tc | 0 | - | +70 | °C |
| Operating Case Temperature | Tc | -20 | - | +85 | °C |
| Operating Case Temperature | Tc | -40 | - | +85 | °C |
| Power Supply Voltage | Vcc | 3.1 | 3.3 | 3.5 | V |
| Power Supply Current | Icc | - | - | 300 | mA |
| Data Rate | DR | - | 1250 | - | Mbps |
4. Optical Specifications
| Section | Parameter | Symbol | Min | Typ | Max | Unit | Note |
| Transmitter | Center Wavelength | λc | 1291 | 1310 | 1330 | nm | - |
| Transmitter | Center Wavelength | λc | 1531 | 1550 | 1570 | nm | - |
| Transmitter | Spectral Width | Δλ | - | - | 4 | nm | FP |
| Transmitter | Spectral Width | Δλ | - | - | 1 | nm | DFB |
| Transmitter | Average Optical Output Power | Po | -9 | - | -3 | dBm | 1310nm |
| Transmitter | Average Optical Output Power | Po | -10 | - | 0 | dBm | 1550nm |
| Transmitter | Extinction Ratio | ER | 9 | - | - | dB | - |
| Transmitter | Optical Rise/Fall Time (20%–80%) | Tr/Tf | - | - | 0.27 | ns | - |
| Transmitter | Output Eye Diagram | - | Compliant with ITU-T G.957 | - | |||
| Receiver | Operate Wavelength | λc | 1291 | 1310 | 1330 | nm | - |
| Receiver | Operate Wavelength | λc | 1531 | 1550 | 1570 | nm | - |
| Receiver | Receiver Sensitivity | RSENS | - | - | -24 | dBm | Note 1: 2^7-1 PRBS @ 1.25Gbps |
| Receiver | Receiver Saturation | PRS | -3 | - | - | dBm | Note 1: 2^7-1 PRBS @ 1.25Gbps |
| Receiver | LOS Assert | - | -40 | - | - | dBm | Alarm: High-level |
| Receiver | LOS De-Assert | - | - | - | -24 | dBm | - |
| Receiver | LOS Hysteresis | - | 0.5 | - | 5 | dBm | - |
5. Electrical Specifications
| Section | Parameter | Symbol | Min | Typ | Max | Unit | Note |
| Transmitter | Power Supply Current | ICCT | - | 70 | 150 | mA | Note 1: Excludes output load current |
| Transmitter | Input Differential Impedance | ZIN | 90 | 100 | 110 | Ω | - |
| Transmitter | Input Swing Differential Voltage | VIN | 500 | - | 2400 | mV | Note 2: PECL input, internally AC-coupled and terminated |
| Transmitter | TX-Disable Voltage (Disable) | - | 2.0 | - | Vcc | V | - |
| Transmitter | TX-Disable Voltage (Enable) | - | 0 | - | 0.8 | V | - |
| Transmitter | TX-Fault Voltage (Fault) | - | 2.0 | - | Vcc | V | - |
| Transmitter | TX-Fault Voltage (Normal) | - | 0 | - | 0.8 | V | - |
| Receiver | Power Supply Current | ICCT | - | 70 | 140 | mA | Note 1: Excludes output load current |
| Receiver | Output Swing Differential Voltage | VOUT | 600 | - | 2000 | mV | Note 3: Internally AC-coupled |
| Receiver | LOS Voltage (High) | - | 2.0 | - | Vcc | V | - |
| Receiver | LOS Voltage (Low) | - | 0 | - | 0.8 | V | - |
6. Diagnostics Specification (SFF-8472, Address A2h, EEPROM Locations 56–95 Calibration Constants)
| Parameter | Range | Accuracy | Unit | Calibration |
| Temperature | 0 to +70 | ±3 | °C | Internal/External |
| Temperature | -40 to +85 | ±3 | °C | Internal/External |
| Voltage | 3.0 to 3.6 | ±3% | V | Internal/External |
| Bias Current | 0 to 100 | ±10% | mA | Internal/External |
| TX Power | -9 to -3 | ±3 | dBm | Internal/External |
| RX Power | -24 to -3 | ±3 | dBm | Internal/External |
7. Pin Definitions & Recommended Host Circuit Notes
| Pin | Name | Description | Notes |
| 1 | VEET | Transmitter Ground | - |
| 2 | TX FAULT | Transmitter Fault Indication | Note 1: Open collector output, pull up with 4.7k–10kΩ resistor on host board to 2.0V–Vcc+0.3V. Logic 0 (<0.8V) = normal operation; Logic 1 = laser fault. |
| 3 | TX DISABLE | Transmitter Disable | Note 2: Pulled up within module with 4.7k–10kΩ resistor. Low (0 to 0.8V): Transmitter on; (>0.8V, <2.0V): Undefined; High (2.0 to 3.465V): Transmitter Disabled; Open: Transmitter Disabled. |
| 4 | MOD_DEF(2) | SDA Serial Data Signal | Note 3: 2-wire serial interface data line; pull up with 4.7k–10kΩ resistor on host board to VCCT or VCC. |
| 5 | MOD_DEF(1) | SCL Serial Clock Signal | Note 3: 2-wire serial interface clock line; pull up with 4.7k–10kΩ resistor on host board to VCCT or VCC. |
| 6 | MOD_DEF(0) | Module Absent. Grounded within the module | Note 3: Grounded inside module to indicate presence; pull up with 4.7k–10kΩ resistor on host board. |
| 7 | Rate Select | Not Connected | - |
| 8 | LOS | Loss of Signal | Note 4: Open collector output, pull up with 4.7k–10kΩ resistor to 2.0V–Vcc+0.3V. Logic 1 = loss of signal; Logic 0 (<0.8V) = normal operation. |
| 9 | VEER | Receiver ground | - |
| 10 | VEER | Receiver ground | - |
| 11 | VEER | Receiver ground | - |
| 12 | RD- | Inv. Received Data Out | Note 5: Internally AC-coupled 100Ω differential lines; terminate with 100Ω (differential) at user SERDES. |
| 13 | RD+ | Received Data Out | Note 5: Internally AC-coupled 100Ω differential lines; terminate with 100Ω (differential) at user SERDES. |
| 14 | VEER | Receiver ground | - |
| 15 | VccR | Receiver Power Supply | 3.3V ±5% |
| 16 | VccT | Transmitter Power Supply | 3.3V ±5% |
| 17 | VEET | Transmitter Ground | - |
| 18 | TD+ | Transmit Data In | Note 6: Internally AC-coupled, differential lines with 100Ω differential termination inside the module. |
| 19 | TD- | Inv. Transmit Data In | Note 6: Internally AC-coupled, differential lines with 100Ω differential termination inside the module. |
| 20 | VEET | Transmitter Ground | - |
Product Variants & Ordering Information
The DFP2-XX24-2XYXX series offers paired 1310nm/1550nm wavelengths, simplex LC or SC interfaces, and Commercial (0°C to +70°C) or Industrial (-40°C to +85°C) case temperatures.
| Model | Specification Description |
| DFP2-3024-2CY1D | SFP BIDI/Single Mode/1.25G/T1310-R1550nm/20KM/3.3V/LC/0 ~ +70°C |
| DFP2-3024-2IY1D | SFP BIDI/Single Mode/1.25G/T1310-R1550nm/20KM/3.3V/LC/-40 ~ +85°C |
| DFP2-5524-2CY1D | SFP BIDI/Single Mode/1.25G/T1550-R1310nm/20KM/3.3V/LC/0 ~ +70°C |
| DFP2-5524-2IY1D | SFP BIDI/Single Mode/1.25G/T1550-R1310nm/20KM/3.3V/LC/-40 ~ +85°C |
| DFP2-3024-2CY2 | SFP BIDI/Single Mode/1.25G/T1310-R1550nm/20KM/3.3V/SC/0 ~ +70°C |
| DFP2-3024-2IY2 | SFP BIDI/Single Mode/1.25G/T1310-R1550nm/20KM/3.3V/SC/-40 ~ +85°C |
| DFP2-5524-2CY2 | SFP BIDI/Single Mode/1.25G/T1550-R1310nm/20KM/3.3V/SC/0 ~ +70°C |
| DFP2-5524-2IY2 | SFP BIDI/Single Mode/1.25G/T1550-R1310nm/20KM/3.3V/SC/-40 ~ +85°C |
OEM / ODM Customization: Extended operating case temperature (-20°C to +85°C) builds, custom switch/router EEPROM compatibility coding, and private label/packaging customization are supported for project and distributor orders.
Applications of 1.25G BiDi SFP Transceiver Modules
The 1.25G BiDi SFP transceiver module supports single-fiber 1.25Gbps optical links across carrier, enterprise, and access network environments.
Fast / Gigabit Ethernet Links: Connects switches and routers over single-strand SMF up to 20km without consuming dual-fiber ports.
ATM / SONET / SDH Transmission Systems: Provides ITU-T G.957 compliant optical eye performance for carrier transport and optical transmission systems.
Switch / Router Interconnects: Links aggregation switches, edge routers, and remote network nodes over single-mode fiber spans.
FTTH & ODN Access Networks: Maximizes fiber core utilization on single-mode distribution and feeder links in broadband access deployments.
Enterprise Broadband & Industrial Networks: Industrial-grade (-40°C to +85°C) units support unconditioned equipment cabinets and continuous field operation.
Typical Network Architecture
A point-to-point single-fiber link pairs complementary 1.25G BiDi SFP modules across one 9/125μm SMF strand between network equipment and remote nodes:
OLT / Core Switch: Insert a TX 1310nm / RX 1550nm module (e.g., DFP2-3024-2CY1D) into a 1.25G SFP port on the central switch or OLT uplink.
Patch Panel & Trunk Cable: Connect the simplex LC or SC port via a single-mode simplex patch cord to an ODF patch panel and route over a single-strand 9/125μm SMF trunk cable up to 20km.
Distribution / Terminal Box: Terminate the single fiber at a distribution or terminal enclosure along the route or building entrance.
Remote Switch / Router / End Device: Install a matching TX 1550nm / RX 1310nm module (e.g., DFP2-5524-2CY1D) on the remote switch or router to complete bidirectional 1.25Gbps communication.
Engineering Selection, Compatibility & Installation Guidelines
Follow these four engineering practices during design and installation to ensure reliable single-fiber operation:
Pair Complementary Wavelengths: Always pair a TX 1310nm / RX 1550nm transceiver on one end with a TX 1550nm / RX 1310nm transceiver on the other end; using identical wavelengths on both ends prevents bidirectional transmission.
Verify Optical Link Budget: With minimum TX power of -9 dBm (1310nm) or -10 dBm (1550nm) and receiver sensitivity of -24 dBm, budget for 9/125μm SMF attenuation, splices, and connector losses across the 20km span while keeping received power within -24 dBm to -3 dBm (saturation).
Match Connector Polish & Clean End Faces: Use compatible simplex LC or SC single-mode patch cords, avoid mismatched connector polishes, and clean optical ferrules before mating to prevent excess insertion loss or reflection.
Apply ESD & Host Pull-Up Rules: Observe ESD protection when handling SFP modules, keep dust caps in place until connection, and verify host board 4.7k–10kΩ pull-ups on open-collector TX FAULT and LOS lines and MOD_DEF(0,1,2) pins.
Comparison Table: 1.25G BiDi SFP vs. Traditional Duplex SFP
| Feature | This Product (1.25G BiDi SFP) | Traditional Solution (1.25G Duplex SFP) |
| Fiber Strands per Link | 1 strand of 9/125μm SMF | 2 strands (TX + RX) of 9/125μm SMF |
| Wavelengths | Paired 1310nm and 1550nm (TX/RX) | Single nominal wavelength per direction (e.g., 1310nm) |
| Optical Interface | Simplex LC or Simplex SC | Duplex LC |
| Fiber & Patch Density | Doubles link count per single-mode fiber strand | 1 link per 2 fiber strands |
| Transmission Reach | Up to 20 km on 9/125μm SMF | Up to 20 km on 9/125μm SMF |
| DDM Monitoring | SFF-8472 DDMI (address A2h) | SFF-8472 DDMI |
Related Products
Pair the 1.25G BiDi SFP transceiver with complementary optical connectivity and transceiver hardware:
Simplex LC & SC Single-Mode Patch Cords: 9/125μm single-fiber jumpers for connecting BiDi SFP modules to patch panels or devices.
Fiber Patch Panels (ODF): Rack- or wall-mount distribution frames for terminating and organizing single-mode trunk fibers.
LC & SC Fiber Optic Adapters: Panel feed-through adapters for simplex and duplex single-mode interconnects.
Fiber Terminal / Distribution Boxes: Enclosures for protecting fiber splices and distribution points in access networks.
10G BiDi SFP+ Transceiver Modules: Higher-rate single-fiber optical transceivers for network capacity upgrades.
FAQ
Q1: What is a 1.25G BiDi SFP transceiver module?
A 1.25G BiDi SFP is a bidirectional SFP optical transceiver module that transmits and receives 1.25Gbps data over a single 9/125μm single-mode fiber up to 20km using 1310nm and 1550nm wavelengths.
Q2: How are 1.25G BiDi SFP modules paired?
They must be used in complementary pairs: a TX 1310nm / RX 1550nm module connects over single-mode fiber to a TX 1550nm / RX 1310nm module at the opposite end.
Q3: Can a BiDi SFP link with a standard dual-fiber 1310nm SFP?
No. Bidirectional single-fiber transceivers require a matching 1310nm/1550nm BiDi counterpart at the far end and cannot link with a standard dual-fiber SFP.
Q4: What operating temperature ranges are available?
The series supports Standard/Commercial (0°C to +70°C), Extended (-20°C to +85°C), and Industrial (-40°C to +85°C) operating case temperatures, with storage from -40°C to +85°C.
Q5: Does it support Digital Diagnostic Monitoring (DDM)?
Yes. It includes a SFF-8472 DDMI interface using a 2-wire serial CMOS EEPROM (address A2h) to monitor temperature, supply voltage, bias current, TX power, and RX power.
Q6: Is OEM customization and switch compatibility coding supported?
Yes. Spring Optical supports custom EEPROM coding for target switches/routers, extended temperature options (-20°C to +85°C), and OEM labeling/packaging upon request.
Quality Assurance & Manufacturer Profile
Shenzhen Spring Optical Communication Co., Ltd. (Spring Optical) is a fiber optic manufacturer and supplier in Shenzhen, China, with over 14 years of industry experience.
Testing & Quality Control: Every transceiver module is tested for optical output power, extinction ratio, receiver sensitivity, ITU-T G.957 eye-diagram compliance, and SFF-8472 DDM calibration under an ISO 9001 quality management system, with RoHS lead-free compliance.
Manufacturing & OEM/ODM Capability: Backed by a 9,000-square-meter production base, 300+ employees, dust-free workshops, and dedicated transceiver and cable production lines, Spring Optical provides OEM/ODM customization and volume supply for global telecom operators, ISPs, and distributors.
Packing, Storage & Shipping
Packaging Type: Supplied with protective optical dust caps in anti-static ESD packaging and outer cartons suited for safe handling and transport.
Storage Conditions: Store in a dry, clean environment within -40°C to +85°C storage temperature limits and avoid moisture condensation or mechanical stress.
Shipping Method: Shipped via international courier, air freight, or sea freight according to order urgency and volume.
Handling Precautions: Follow ESD precautions when handling modules, keep dust caps installed until connecting clean LC/SC fiber connectors, and never look into active optical ports.
Contact Spring Optical for technical consultation, switch compatibility coding, OEM customization, or project-based 1.25G BiDi SFP transceiver solutions. Our team provides datasheets, compatibility support, and quotations for telecom operators, ISPs, and distributors.
Hot Tags: 1.25G BiDi SFP,SFP Transceiver Module, Optical Transceiver, BiDi SFP, SFP Transceiver, Optical Module, 1.25G SFP, SFP Module, Transceiver Module, BiDi SFP supplier