25G SFP28 LR Transceiver Module 1310nm 10KM Single Mode Duplex LC DDM

25G SFP28 LR Transceiver Module 1310nm 10KM Single Mode Duplex LC DDM
Details:
·25.78Gbps Data Rate & 10KM Reach - Supports 25G optical transmission over single-mode fiber links up to 10KM.
·1310nm DFB Laser & Duplex LC - Uses a DFB transmitter and PIN/TIA receiver with separate TX and RX connections.
·Industrial Temperature Options - Commercial 0 to +70C and industrial -40 to +85C operating temperature ranges.
·Digital Diagnostic Monitoring (DDM) - Monitors TX/RX optical power, temperature, supply voltage, and laser bias current.
·Hot-Pluggable SFP28 Design - Single 3.3V power supply with maximum power dissipation below 1.2W.
·25G Ethernet & CPRI Support - Designed for 25GBASE-LR Ethernet and CPRI 10 applications with SFF-8472 compliance.
Send Inquiry
Description
Send Inquiry

Spring Optical Communication is one of the largest and best 25g sfp28 lr transceiver module 1310nm 10km single mode duplex lc ddm manufacturers and suppliers with rich experience. Welcome to buy our high quality products or wholesale our customized 25g sfp28 lr transceiver module 1310nm 10km single mode duplex lc ddm in stock with our factory. Also, free sample is also available if necessary.

 

The 25G SFP28 LR Transceiver Module is a dual-fiber optical transceiver designed for 25.78Gbps data transmission over distances up to 10KM using single-mode fiber. Featuring a 1310nm DFB laser, PIN/TIA receiver, duplex LC interface, and digital diagnostic monitoring (DDM), it supports 25GBASE-LR Ethernet and CPRI 10 applications.

Product Overview

25g-sfp28-lr-transceiver-10km

Spring Optical's 25G SFP28 LR Transceiver Module supports 25.78Gbps optical transmission over single-mode fiber links up to 10KM. The DPP1-3125-1XY1 series integrates a 1310nm DFB laser transmitter, PIN/TIA receiver, and duplex LC optical interface for separate transmit and receive connections.

The optical module features a hot-pluggable SFP28 footprint, a single 3.3V DC power supply, and an I2C management interface with digital diagnostic monitoring for temperature, supply voltage, laser bias current, and TX/RX optical power. Maximum power dissipation is specified below 1.2W.

Designed for 25GBASE-LR Ethernet and CPRI 10 applications, the transceiver is specified as compliant with SFP MSA, IEEE 802.3cc, and SFF-8472. Commercial and industrial temperature configurations are available for different network environments.

Key Features & Engineering Advantages

25.78Gbps Data Rate & 10KM Reach - Supports 25G optical transmission over single-mode fiber links up to 10KM.

1310nm DFB Laser & Duplex LC - Uses a DFB transmitter and PIN/TIA receiver with separate TX and RX connections.

Industrial Temperature Options - Commercial 0 to +70C and industrial -40 to +85C operating temperature ranges.

Digital Diagnostic Monitoring (DDM) - Monitors TX/RX optical power, temperature, supply voltage, and laser bias current.

Hot-Pluggable SFP28 Design - Single 3.3V power supply with maximum power dissipation below 1.2W.

25G Ethernet & CPRI Support - Designed for 25GBASE-LR Ethernet and CPRI 10 applications with SFF-8472 compliance.

Technical Specifications

General Specifications

Parameter Specification
Product Series DPP1-3125-1XY1
Document Version V0.1
Product Type 25G SFP28 LR Dual Fiber Transceiver
Data Rate 25.78Gbps
Signaling Rate 25.7825GBd +/-100ppm
Transmission Distance 10KM
Nominal Wavelength 1310nm
Fiber Type Single Mode Fiber (SMF)
Optical Interface Duplex LC
Transmitter 1310nm DFB Laser
Receiver PIN/TIA
Form Factor Hot-Pluggable SFP28
Power Supply Single +3.3V DC
Maximum Power Dissipation Less Than 1.2W
Management Interface I2C
Digital Diagnostics DDM
Standards Compliance SFP MSA, IEEE 802.3cc, SFF-8472
Environmental Compliance RoHS-6 Compliant, Lead-Free
Commercial Temperature 0 to +70C
Industrial Temperature -40 to +85C
Applications 25GBASE-LR Ethernet, CPRI 10

Absolute Maximum Ratings

Parameter Symbol Min Max Unit
Maximum Supply Voltage Vcc -0.5 3.6 V
Storage Temperature TS -40 85 C
Relative Humidity RH 0 85 %

Note: Exceeding any absolute maximum rating may immediately damage the device.

Optical Characteristics - Transmitter

Parameter Symbol Min Typ Max Unit
Signaling Rate Sr - 25.7825 +/-100ppm - GBd
Center Wavelength lambda c 1295 1310 1325 nm
Spectral Width (-20dB) Pm - - 1 nm
Average Output Power Pavg -7 - 2 dBm
Extinction Ratio ER 3.5 - - dB
Side Mode Suppression Ratio SMSR 30 - - dB
Transmitter OFF Output Power POff - - -30 dBm

Transmitter Eye Mask

Parameter Value
Eye Mask Definition X1, X2, X3, Y1, Y2, Y3
X1 0.31
X2 0.40
X3 0.45
Y1 0.34
Y2 0.38
Y3 0.40
Hit Ratio 5 x 10-5 hits per sample

Optical Characteristics - Receiver

Parameter Symbol Min Typ Max Unit Note
Signaling Rate Sr - 25.7825 +/-100ppm - GBd -
Center Wavelength lambda c 1295 1310 1325 nm -
Receiver Sensitivity (OMA) - - - -12 dBm 1
Receiver Reflectance Rfl - - -26 dBm Source unit
Loss of Signal Assert PA -30 - - dBm -
Loss of Signal Deassert PD - - -13 dBm -
LOS Hysteresis PD - PA 0.5 - - dB -

Note 1: Receiver sensitivity is specified using a hit ratio of 5 x 10-5.

The Min/Typ/Max placement for receiver sensitivity and reflectance should be checked against the approved original specification before publication.

Electrical Interface Characteristics

Parameter Symbol Min Typ Max Unit Notes
Supply Voltage Vcc 3.135 3.3 3.465 V -
Supply Current - Commercial Icc - - 300 mA Commercial
Supply Current - Industrial Icc - - 360 mA Industrial

Transmitter Electrical Characteristics

Parameter Symbol Min Typ Max Unit Notes
Input Differential Impedance Rin - 100 - Ohm 1
Differential Data Input Swing Vin, pp 100 - 800 mV -
Transmit Disable Voltage VD 2 - VCC V -
Transmit Enable Voltage VEN Vee - Vee+0.8 V -

Receiver Electrical Characteristics

Parameter Symbol Min Typ Max Unit Notes
Differential Data Output Swing Vout, pp 100 - 800 mV 2
LOS Fault VLOS_fault 2 - VccHOST V 3
LOS Normal VLOS_norm Vee - Vee+0.8 V 3

Electrical Notes

TX data inputs are connected directly to the input pins. AC coupling is provided between the pins and laser driver IC.

RX output swing is specified into a 100 Ohm differential termination.

LOS is an open-collector output. A host-side pull-up resistor of 4.7k-10k Ohms is required. Logic 0 indicates normal operation and logic 1 indicates loss of signal. The electrical-interface note specifies a maximum pull-up voltage of 5.5V.

Digital Diagnostic Specifications

The SFP28 optical transceiver supports digital diagnostic monitoring through the I2C management interface.

Parameter Unit Accuracy
Case Temperature C +/-3
Supply Voltage V +/-3%
TX Bias Current mA +/-10%
TX Optical Power dB +/-3
RX Optical Power dB +/-3

Digital Diagnostic Memory Map

The original specification contains a Digital Diagnostic Memory Map section.

The detailed memory-address information is not included in the supplied text. The original approved memory map should be inserted here for engineering reference.

Recommended Interface Circuit

The module uses separate transmitter and receiver power pins, differential electrical data connections, and a two-wire serial management interface.

The host design should follow the specified 3.3V supply requirements, transmitter disable control, receiver LOS signaling, and electrical termination requirements.

The original Recommended Interface Circuit drawing should be retained in the final product page.

Pin Definitions

Pin Symbol Description Notes
1 VEET Transmitter Ground, Common with Receiver Ground 1
2 TFAULT Transmitter Fault 2
3 TDIS Transmitter Disable; Laser Disabled on HIGH or Open 3
4 SDA Two-Wire Serial Interface Data Line 4
5 SCL Two-Wire Serial Interface Clock Line 4
6 MOD_ABS Module Absent, Grounded Within Module 4
7 RS0 No Connection Required -
8 LOS Loss of Signal; Logic 0 Indicates Normal Operation 5
9 RS1 No Connection Required -
10 VEER Receiver Ground, Common with Transmitter Ground 1
11 VEER Receiver Ground, Common with Transmitter Ground 1
12 RD- Receiver Inverted Data Output, AC-Coupled -
13 RD+ Receiver Non-Inverted Data Output, AC-Coupled -
14 VEER Receiver Ground, Common with Transmitter Ground 1
15 VCCR Receiver Power Supply -
16 VCCT Transmitter Power Supply -
17 VEET Transmitter Ground, Common with Receiver Ground 1
18 TD+ Transmitter Non-Inverted Data Input, AC-Coupled -
19 TD- Transmitter Inverted Data Input, AC-Coupled -
20 VEET Transmitter Ground, Common with Receiver Ground 1

Pin Configuration Notes

Circuit ground is internally isolated from chassis ground.

TFAULT is an open-collector/open-drain output requiring a 4.7k-10k Ohm pull-up resistor on the host board. The source also refers to grounding within an SFP+ cable plug; this statement requires confirmation for the optical module.

Laser output is disabled when TDIS exceeds 2.0V or is left open. The transmitter is enabled when TDIS is below 0.8V.

SDA, SCL, and associated module-definition lines use 4.7k-10k Ohm pull-up resistors to a host voltage between 2.0V and 3.6V. MOD_ABS is pulled LOW to indicate that the module is installed.

LOS is an open-collector output requiring a 4.7k-10k Ohm pull-up resistor to a host voltage between 2.0V and 3.6V. Logic 0 indicates normal operation, while logic 1 indicates loss of signal.

Mechanical Specifications

Parameter Specification
Form Factor SFP28
Installation Type Hot-Pluggable
Optical Interface Duplex LC
Fiber Configuration Dual Fiber
Fiber Type Single Mode
Mechanical Dimensions Refer to Original Engineering Drawing

The original specification includes a mechanical drawing. Numeric dimensions and tolerances are not available in the supplied text and should be retained from the approved drawing.

Product Variants & Ordering Information

The DPP1-3125 series provides two 1310nm 10KM dual-fiber SFP28 LR transceiver models for commercial and industrial operating environments.

Model Data Rate Wavelength Distance Connector DDM Fiber Temperature
DPP1-3125-1CY1 25.78Gbps 1310nm 10KM Duplex LC Yes SMF 0 to +70C
DPP1-3125-1IY1 25.78Gbps 1310nm 10KM Duplex LC Yes SMF -40 to +85C

OEM/ODM Options for Technical Review

Host switch compatibility and EEPROM coding

Product identification and private labeling

Commercial and industrial temperature selection

Packaging customization

Project-specific qualification requirements

Customized configurations should be confirmed before ordering.

25G SFP28 LR Transceiver Module Applications

The 25G SFP28 LR transceiver supports high-speed single-mode optical connections up to 10KM in compatible 25Gbps network equipment.

25GBASE-LR Ethernet: 25Gbps-class optical links between compatible Ethernet switches and network devices.

CPRI 10: Optical interfaces for compatible high-speed radio access equipment.

Telecom Access Networks: Single-mode fiber connections between compatible aggregation and access switches.

Enterprise Fiber Networks: 25Gbps optical links between equipment rooms, buildings, and network distribution points.

Typical Network Architecture

The 25G SFP28 LR transceiver uses separate optical fibers for transmit and receive connections.

25G Core / Aggregation Switch -> 25G SFP28 LR Module -> Duplex LC Patch Cord -> Single Mode Fiber Link (up to 10KM) -> Remote 25G SFP28 LR Module -> 25G Access Switch

Both endpoints must use compatible optical interfaces and correct TX/RX fiber connections.

Engineering Selection & Installation Guidelines

1. Verify Single-Mode Fiber and Duplex Polarity

Use compatible single-mode fiber with duplex LC connections. This product uses two fibers, not a single-fiber BiDi interface. Connect TX at one endpoint to RX at the other endpoint and verify the reverse path.

2. Evaluate the Optical Link Budget

The published minimum average TX power is -7 dBm, while receiver sensitivity is specified as -12 dBm in OMA.

These values use different optical power measurement definitions, so they should not be directly subtracted to claim a verified average-power link budget.

Confirm the complete optical channel budget using the manufacturer's applicable receiver sensitivity, transmitter OMA, dispersion requirements, and installed fiber losses.

3. Confirm Host Compatibility and Power

Verify that the host equipment supports the specified 25Gbps-class SFP28 interface, 3.3V supply, and I2C management functions.

The maximum specified supply current is 300mA for commercial models and 360mA for industrial models. Ensure sufficient host-port power capacity.

4. Follow Optical Cleaning and ESD Procedures

Inspect and clean LC connector end faces before installation. Protect unused ports from dust, avoid excessive fiber bending, and apply ESD-safe handling procedures. Do not look directly into an active optical interface.

Frequently Asked Questions

1. What is a 25G SFP28 LR transceiver module?

A 25G SFP28 LR transceiver module is a hot-pluggable optical device designed for 25Gbps-class data transmission over single-mode fiber. Spring Optical's 1310nm LR model supports links up to 10KM with a DFB transmitter, PIN/TIA receiver, duplex LC interface, and digital diagnostic monitoring.

2. What is the difference between 25G SFP28 LR and SR?

25G SFP28 LR modules are designed for longer-distance single-mode fiber links, while SR modules use multimode fiber for shorter connections. This LR model supports 10KM at 1310nm. SR and LR transceivers should not be mixed without verifying their optical compatibility.

3. What is the maximum transmission distance?

The maximum specified transmission distance is 10KM over single-mode fiber. Actual supported distance depends on transmitter power, receiver performance, fiber attenuation, connector and splice losses, and the complete optical channel design. A 10KM specification does not guarantee operation over every installed fiber route.

4. Is this SFP28 LR module compatible with Cisco or other switches?

Compatibility depends on the host equipment, firmware, SFP28 electrical interface, and module EEPROM identification requirements. SFP MSA and SFF-8472 compliance do not automatically guarantee vendor-specific acceptance. Host model information should be checked before ordering modules for third-party network equipment.

5. What operating temperature options are available?

The commercial model supports an operating temperature range of 0 to +70C, while the industrial model supports -40 to +85C. Both versions provide a 1310nm transmitter, 10KM single-mode transmission, duplex LC interface, and DDM functionality.

6. Does the module support digital diagnostic monitoring?

Yes. The module provides digital diagnostic monitoring for case temperature, supply voltage, laser bias current, transmitted optical power, and received optical power. These measurements are accessible through the management interface when supported by the host equipment.

Quality Assurance & OEM/ODM Manufacturing

Shenzhen Spring Optical Communication Co., Ltd. supplies optical communication products for telecom operators, ISPs, system integrators, and distributors.

Spring Optical supports OEM/ODM coordination for optical transceiver modules, including host compatibility review, product labeling, packaging, and project-specific technical requirements.

Relevant Product Verification

Transmitter wavelength and optical power measurement

Receiver sensitivity and optical performance testing

Optical eye mask and signal quality evaluation

Electrical interface and supply voltage verification

DDM monitoring and I2C communication checks

Temperature performance evaluation

Host equipment compatibility testing

Product appearance and LC connector inspection

Actual production test coverage and inspection frequency should be confirmed against the approved quality control plan.

Packing, Storage & Shipping

The specified storage temperature range is -40 to +85C, with relative humidity from 0% to 85%.

Modules should be protected from electrostatic discharge, mechanical impact, dust, and connector contamination. Use suitable protective packing and keep optical interfaces covered during storage and transportation.

Packing quantities, carton dimensions, delivery schedules, and international shipping arrangements should be confirmed according to the final order requirements.

Related Products

Product Application
25G SFP28 SR Transceiver Module Short-range 25G multimode connections
25G SFP28 BiDi Transceiver Single-fiber alternative for compatible 25G links
10G SFP+ LR Transceiver Module 10Gbps single-mode fiber connections
100G QSFP28 LR4 Transceiver Higher-speed long-distance optical links
OS2 Single Mode Fiber Patch Cord Duplex LC connectivity for single-mode fiber links
Fiber Optic Patch Panel Fiber termination, routing, and cable management

Request Datasheet & Quotation

Contact Spring Optical for the 25G SFP28 LR transceiver datasheet, host compatibility review, OEM/ODM requirements, sample evaluation, or project quotation.

Please provide the host switch model, required temperature grade, order quantity, and any specific compatibility coding requirements.

Hot Tags: 25G SFP28, SFP28 Transceiver, Optical Transceiver, SFP28 Transceiver Module, Optical Module, Transceiver Module, 25GBASE-LR, 25G Optical Transceiver

Send Inquiry