Spring Optical Communication is one of the largest and best 25g sfp28 lr transceiver module 1310nm 10km single mode duplex lc ddm manufacturers and suppliers with rich experience. Welcome to buy our high quality products or wholesale our customized 25g sfp28 lr transceiver module 1310nm 10km single mode duplex lc ddm in stock with our factory. Also, free sample is also available if necessary.
The 25G SFP28 LR Transceiver Module is a dual-fiber optical transceiver designed for 25.78Gbps data transmission over distances up to 10KM using single-mode fiber. Featuring a 1310nm DFB laser, PIN/TIA receiver, duplex LC interface, and digital diagnostic monitoring (DDM), it supports 25GBASE-LR Ethernet and CPRI 10 applications.
Product Overview

Spring Optical's 25G SFP28 LR Transceiver Module supports 25.78Gbps optical transmission over single-mode fiber links up to 10KM. The DPP1-3125-1XY1 series integrates a 1310nm DFB laser transmitter, PIN/TIA receiver, and duplex LC optical interface for separate transmit and receive connections.
The optical module features a hot-pluggable SFP28 footprint, a single 3.3V DC power supply, and an I2C management interface with digital diagnostic monitoring for temperature, supply voltage, laser bias current, and TX/RX optical power. Maximum power dissipation is specified below 1.2W.
Designed for 25GBASE-LR Ethernet and CPRI 10 applications, the transceiver is specified as compliant with SFP MSA, IEEE 802.3cc, and SFF-8472. Commercial and industrial temperature configurations are available for different network environments.
Key Features & Engineering Advantages
25.78Gbps Data Rate & 10KM Reach - Supports 25G optical transmission over single-mode fiber links up to 10KM.
1310nm DFB Laser & Duplex LC - Uses a DFB transmitter and PIN/TIA receiver with separate TX and RX connections.
Industrial Temperature Options - Commercial 0 to +70C and industrial -40 to +85C operating temperature ranges.
Digital Diagnostic Monitoring (DDM) - Monitors TX/RX optical power, temperature, supply voltage, and laser bias current.
Hot-Pluggable SFP28 Design - Single 3.3V power supply with maximum power dissipation below 1.2W.
25G Ethernet & CPRI Support - Designed for 25GBASE-LR Ethernet and CPRI 10 applications with SFF-8472 compliance.
Technical Specifications
General Specifications
| Parameter | Specification |
|---|---|
| Product Series | DPP1-3125-1XY1 |
| Document Version | V0.1 |
| Product Type | 25G SFP28 LR Dual Fiber Transceiver |
| Data Rate | 25.78Gbps |
| Signaling Rate | 25.7825GBd +/-100ppm |
| Transmission Distance | 10KM |
| Nominal Wavelength | 1310nm |
| Fiber Type | Single Mode Fiber (SMF) |
| Optical Interface | Duplex LC |
| Transmitter | 1310nm DFB Laser |
| Receiver | PIN/TIA |
| Form Factor | Hot-Pluggable SFP28 |
| Power Supply | Single +3.3V DC |
| Maximum Power Dissipation | Less Than 1.2W |
| Management Interface | I2C |
| Digital Diagnostics | DDM |
| Standards Compliance | SFP MSA, IEEE 802.3cc, SFF-8472 |
| Environmental Compliance | RoHS-6 Compliant, Lead-Free |
| Commercial Temperature | 0 to +70C |
| Industrial Temperature | -40 to +85C |
| Applications | 25GBASE-LR Ethernet, CPRI 10 |
Absolute Maximum Ratings
| Parameter | Symbol | Min | Max | Unit |
|---|---|---|---|---|
| Maximum Supply Voltage | Vcc | -0.5 | 3.6 | V |
| Storage Temperature | TS | -40 | 85 | C |
| Relative Humidity | RH | 0 | 85 | % |
Note: Exceeding any absolute maximum rating may immediately damage the device.
Optical Characteristics - Transmitter
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Signaling Rate | Sr | - | 25.7825 +/-100ppm | - | GBd |
| Center Wavelength | lambda c | 1295 | 1310 | 1325 | nm |
| Spectral Width (-20dB) | Pm | - | - | 1 | nm |
| Average Output Power | Pavg | -7 | - | 2 | dBm |
| Extinction Ratio | ER | 3.5 | - | - | dB |
| Side Mode Suppression Ratio | SMSR | 30 | - | - | dB |
| Transmitter OFF Output Power | POff | - | - | -30 | dBm |
Transmitter Eye Mask
| Parameter | Value |
|---|---|
| Eye Mask Definition | X1, X2, X3, Y1, Y2, Y3 |
| X1 | 0.31 |
| X2 | 0.40 |
| X3 | 0.45 |
| Y1 | 0.34 |
| Y2 | 0.38 |
| Y3 | 0.40 |
| Hit Ratio | 5 x 10-5 hits per sample |
Optical Characteristics - Receiver
| Parameter | Symbol | Min | Typ | Max | Unit | Note |
|---|---|---|---|---|---|---|
| Signaling Rate | Sr | - | 25.7825 +/-100ppm | - | GBd | - |
| Center Wavelength | lambda c | 1295 | 1310 | 1325 | nm | - |
| Receiver Sensitivity (OMA) | - | - | - | -12 | dBm | 1 |
| Receiver Reflectance | Rfl | - | - | -26 | dBm | Source unit |
| Loss of Signal Assert | PA | -30 | - | - | dBm | - |
| Loss of Signal Deassert | PD | - | - | -13 | dBm | - |
| LOS Hysteresis | PD - PA | 0.5 | - | - | dB | - |
Note 1: Receiver sensitivity is specified using a hit ratio of 5 x 10-5.
The Min/Typ/Max placement for receiver sensitivity and reflectance should be checked against the approved original specification before publication.
Electrical Interface Characteristics
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | 3.135 | 3.3 | 3.465 | V | - |
| Supply Current - Commercial | Icc | - | - | 300 | mA | Commercial |
| Supply Current - Industrial | Icc | - | - | 360 | mA | Industrial |
Transmitter Electrical Characteristics
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Input Differential Impedance | Rin | - | 100 | - | Ohm | 1 |
| Differential Data Input Swing | Vin, pp | 100 | - | 800 | mV | - |
| Transmit Disable Voltage | VD | 2 | - | VCC | V | - |
| Transmit Enable Voltage | VEN | Vee | - | Vee+0.8 | V | - |
Receiver Electrical Characteristics
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Differential Data Output Swing | Vout, pp | 100 | - | 800 | mV | 2 |
| LOS Fault | VLOS_fault | 2 | - | VccHOST | V | 3 |
| LOS Normal | VLOS_norm | Vee | - | Vee+0.8 | V | 3 |
Electrical Notes
TX data inputs are connected directly to the input pins. AC coupling is provided between the pins and laser driver IC.
RX output swing is specified into a 100 Ohm differential termination.
LOS is an open-collector output. A host-side pull-up resistor of 4.7k-10k Ohms is required. Logic 0 indicates normal operation and logic 1 indicates loss of signal. The electrical-interface note specifies a maximum pull-up voltage of 5.5V.
Digital Diagnostic Specifications
The SFP28 optical transceiver supports digital diagnostic monitoring through the I2C management interface.
| Parameter | Unit | Accuracy |
|---|---|---|
| Case Temperature | C | +/-3 |
| Supply Voltage | V | +/-3% |
| TX Bias Current | mA | +/-10% |
| TX Optical Power | dB | +/-3 |
| RX Optical Power | dB | +/-3 |
Digital Diagnostic Memory Map
The original specification contains a Digital Diagnostic Memory Map section.
The detailed memory-address information is not included in the supplied text. The original approved memory map should be inserted here for engineering reference.
Recommended Interface Circuit
The module uses separate transmitter and receiver power pins, differential electrical data connections, and a two-wire serial management interface.
The host design should follow the specified 3.3V supply requirements, transmitter disable control, receiver LOS signaling, and electrical termination requirements.
The original Recommended Interface Circuit drawing should be retained in the final product page.
Pin Definitions
| Pin | Symbol | Description | Notes |
|---|---|---|---|
| 1 | VEET | Transmitter Ground, Common with Receiver Ground | 1 |
| 2 | TFAULT | Transmitter Fault | 2 |
| 3 | TDIS | Transmitter Disable; Laser Disabled on HIGH or Open | 3 |
| 4 | SDA | Two-Wire Serial Interface Data Line | 4 |
| 5 | SCL | Two-Wire Serial Interface Clock Line | 4 |
| 6 | MOD_ABS | Module Absent, Grounded Within Module | 4 |
| 7 | RS0 | No Connection Required | - |
| 8 | LOS | Loss of Signal; Logic 0 Indicates Normal Operation | 5 |
| 9 | RS1 | No Connection Required | - |
| 10 | VEER | Receiver Ground, Common with Transmitter Ground | 1 |
| 11 | VEER | Receiver Ground, Common with Transmitter Ground | 1 |
| 12 | RD- | Receiver Inverted Data Output, AC-Coupled | - |
| 13 | RD+ | Receiver Non-Inverted Data Output, AC-Coupled | - |
| 14 | VEER | Receiver Ground, Common with Transmitter Ground | 1 |
| 15 | VCCR | Receiver Power Supply | - |
| 16 | VCCT | Transmitter Power Supply | - |
| 17 | VEET | Transmitter Ground, Common with Receiver Ground | 1 |
| 18 | TD+ | Transmitter Non-Inverted Data Input, AC-Coupled | - |
| 19 | TD- | Transmitter Inverted Data Input, AC-Coupled | - |
| 20 | VEET | Transmitter Ground, Common with Receiver Ground | 1 |
Pin Configuration Notes
Circuit ground is internally isolated from chassis ground.
TFAULT is an open-collector/open-drain output requiring a 4.7k-10k Ohm pull-up resistor on the host board. The source also refers to grounding within an SFP+ cable plug; this statement requires confirmation for the optical module.
Laser output is disabled when TDIS exceeds 2.0V or is left open. The transmitter is enabled when TDIS is below 0.8V.
SDA, SCL, and associated module-definition lines use 4.7k-10k Ohm pull-up resistors to a host voltage between 2.0V and 3.6V. MOD_ABS is pulled LOW to indicate that the module is installed.
LOS is an open-collector output requiring a 4.7k-10k Ohm pull-up resistor to a host voltage between 2.0V and 3.6V. Logic 0 indicates normal operation, while logic 1 indicates loss of signal.
Mechanical Specifications
| Parameter | Specification |
|---|---|
| Form Factor | SFP28 |
| Installation Type | Hot-Pluggable |
| Optical Interface | Duplex LC |
| Fiber Configuration | Dual Fiber |
| Fiber Type | Single Mode |
| Mechanical Dimensions | Refer to Original Engineering Drawing |
The original specification includes a mechanical drawing. Numeric dimensions and tolerances are not available in the supplied text and should be retained from the approved drawing.
Product Variants & Ordering Information
The DPP1-3125 series provides two 1310nm 10KM dual-fiber SFP28 LR transceiver models for commercial and industrial operating environments.
| Model | Data Rate | Wavelength | Distance | Connector | DDM | Fiber | Temperature |
|---|---|---|---|---|---|---|---|
| DPP1-3125-1CY1 | 25.78Gbps | 1310nm | 10KM | Duplex LC | Yes | SMF | 0 to +70C |
| DPP1-3125-1IY1 | 25.78Gbps | 1310nm | 10KM | Duplex LC | Yes | SMF | -40 to +85C |
OEM/ODM Options for Technical Review
Host switch compatibility and EEPROM coding
Product identification and private labeling
Commercial and industrial temperature selection
Packaging customization
Project-specific qualification requirements
Customized configurations should be confirmed before ordering.
25G SFP28 LR Transceiver Module Applications
The 25G SFP28 LR transceiver supports high-speed single-mode optical connections up to 10KM in compatible 25Gbps network equipment.
25GBASE-LR Ethernet: 25Gbps-class optical links between compatible Ethernet switches and network devices.
CPRI 10: Optical interfaces for compatible high-speed radio access equipment.
Telecom Access Networks: Single-mode fiber connections between compatible aggregation and access switches.
Enterprise Fiber Networks: 25Gbps optical links between equipment rooms, buildings, and network distribution points.
Typical Network Architecture
The 25G SFP28 LR transceiver uses separate optical fibers for transmit and receive connections.
25G Core / Aggregation Switch -> 25G SFP28 LR Module -> Duplex LC Patch Cord -> Single Mode Fiber Link (up to 10KM) -> Remote 25G SFP28 LR Module -> 25G Access Switch
Both endpoints must use compatible optical interfaces and correct TX/RX fiber connections.
Engineering Selection & Installation Guidelines
1. Verify Single-Mode Fiber and Duplex Polarity
Use compatible single-mode fiber with duplex LC connections. This product uses two fibers, not a single-fiber BiDi interface. Connect TX at one endpoint to RX at the other endpoint and verify the reverse path.
2. Evaluate the Optical Link Budget
The published minimum average TX power is -7 dBm, while receiver sensitivity is specified as -12 dBm in OMA.
These values use different optical power measurement definitions, so they should not be directly subtracted to claim a verified average-power link budget.
Confirm the complete optical channel budget using the manufacturer's applicable receiver sensitivity, transmitter OMA, dispersion requirements, and installed fiber losses.
3. Confirm Host Compatibility and Power
Verify that the host equipment supports the specified 25Gbps-class SFP28 interface, 3.3V supply, and I2C management functions.
The maximum specified supply current is 300mA for commercial models and 360mA for industrial models. Ensure sufficient host-port power capacity.
4. Follow Optical Cleaning and ESD Procedures
Inspect and clean LC connector end faces before installation. Protect unused ports from dust, avoid excessive fiber bending, and apply ESD-safe handling procedures. Do not look directly into an active optical interface.
Frequently Asked Questions
1. What is a 25G SFP28 LR transceiver module?
A 25G SFP28 LR transceiver module is a hot-pluggable optical device designed for 25Gbps-class data transmission over single-mode fiber. Spring Optical's 1310nm LR model supports links up to 10KM with a DFB transmitter, PIN/TIA receiver, duplex LC interface, and digital diagnostic monitoring.
2. What is the difference between 25G SFP28 LR and SR?
25G SFP28 LR modules are designed for longer-distance single-mode fiber links, while SR modules use multimode fiber for shorter connections. This LR model supports 10KM at 1310nm. SR and LR transceivers should not be mixed without verifying their optical compatibility.
3. What is the maximum transmission distance?
The maximum specified transmission distance is 10KM over single-mode fiber. Actual supported distance depends on transmitter power, receiver performance, fiber attenuation, connector and splice losses, and the complete optical channel design. A 10KM specification does not guarantee operation over every installed fiber route.
4. Is this SFP28 LR module compatible with Cisco or other switches?
Compatibility depends on the host equipment, firmware, SFP28 electrical interface, and module EEPROM identification requirements. SFP MSA and SFF-8472 compliance do not automatically guarantee vendor-specific acceptance. Host model information should be checked before ordering modules for third-party network equipment.
5. What operating temperature options are available?
The commercial model supports an operating temperature range of 0 to +70C, while the industrial model supports -40 to +85C. Both versions provide a 1310nm transmitter, 10KM single-mode transmission, duplex LC interface, and DDM functionality.
6. Does the module support digital diagnostic monitoring?
Yes. The module provides digital diagnostic monitoring for case temperature, supply voltage, laser bias current, transmitted optical power, and received optical power. These measurements are accessible through the management interface when supported by the host equipment.
Quality Assurance & OEM/ODM Manufacturing
Shenzhen Spring Optical Communication Co., Ltd. supplies optical communication products for telecom operators, ISPs, system integrators, and distributors.
Spring Optical supports OEM/ODM coordination for optical transceiver modules, including host compatibility review, product labeling, packaging, and project-specific technical requirements.
Relevant Product Verification
Transmitter wavelength and optical power measurement
Receiver sensitivity and optical performance testing
Optical eye mask and signal quality evaluation
Electrical interface and supply voltage verification
DDM monitoring and I2C communication checks
Temperature performance evaluation
Host equipment compatibility testing
Product appearance and LC connector inspection
Actual production test coverage and inspection frequency should be confirmed against the approved quality control plan.
Packing, Storage & Shipping
The specified storage temperature range is -40 to +85C, with relative humidity from 0% to 85%.
Modules should be protected from electrostatic discharge, mechanical impact, dust, and connector contamination. Use suitable protective packing and keep optical interfaces covered during storage and transportation.
Packing quantities, carton dimensions, delivery schedules, and international shipping arrangements should be confirmed according to the final order requirements.
Related Products
| Product | Application |
|---|---|
| 25G SFP28 SR Transceiver Module | Short-range 25G multimode connections |
| 25G SFP28 BiDi Transceiver | Single-fiber alternative for compatible 25G links |
| 10G SFP+ LR Transceiver Module | 10Gbps single-mode fiber connections |
| 100G QSFP28 LR4 Transceiver | Higher-speed long-distance optical links |
| OS2 Single Mode Fiber Patch Cord | Duplex LC connectivity for single-mode fiber links |
| Fiber Optic Patch Panel | Fiber termination, routing, and cable management |
Request Datasheet & Quotation
Contact Spring Optical for the 25G SFP28 LR transceiver datasheet, host compatibility review, OEM/ODM requirements, sample evaluation, or project quotation.
Please provide the host switch model, required temperature grade, order quantity, and any specific compatibility coding requirements.
Hot Tags: 25G SFP28, SFP28 Transceiver, Optical Transceiver, SFP28 Transceiver Module, Optical Module, Transceiver Module, 25GBASE-LR, 25G Optical Transceiver