25G SFP28 SR Transceiver Module 850nm Multimode 100m Duplex LC DDM

25G SFP28 SR Transceiver Module 850nm Multimode 100m Duplex LC DDM
Details:
·25.78125Gbps Data Rate - Supports high-speed 25GBASE-SR Ethernet over multimode fiber.
·850nm VCSEL & PIN Receiver - Provides short-range optical transmission with a duplex LC interface.
·70m OM3 / 100m OM4 Reach - Supports multimode fiber links according to the selected cable grade.
·Digital Diagnostic Monitoring (DDM) - Monitors temperature, supply voltage, TX bias current, and TX/RX optical power.
·Hot-Pluggable SFP28 Design - Compact optical module with a single 3.3V power supply.
·Commercial Temperature & Standards - Operates from 0 to +70C and complies with the stated SFF interface specifications.
Send Inquiry
Description
Send Inquiry

Spring Optical Communication is one of the largest and best 25g sfp28 sr transceiver module 850nm multimode 100m duplex lc ddm manufacturers and suppliers with rich experience. Welcome to buy our high quality products or wholesale our customized 25g sfp28 sr transceiver module 850nm multimode 100m duplex lc ddm in stock with our factory. Also, free sample is also available if necessary.

 

The 25G SFP28 SR Transceiver Module is an 850nm multimode optical transceiver designed for 25.78125Gbps data transmission. Featuring a VCSEL laser, PIN receiver, duplex LC interface, and digital diagnostic monitoring (DDM), it supports 25GBASE-SR Ethernet links up to 70m over OM3 or 100m over OM4 multimode fiber.

Product Overview

sfp28-25g-850nm-sr-module

Spring Optical's 25G SFP28 SR Transceiver Module supports 25.78125Gbps optical transmission over multimode fiber. The D281-8M25-SCY1 model uses an 850nm VCSEL laser transmitter, PIN photodetector, and duplex LC interface, supporting link distances of 70m on OM3 and 100m on OM4 fiber.

The optical module features a hot-pluggable SFP28 footprint, a single 3.3V power supply, and digital diagnostic monitoring for module temperature, supply voltage, laser bias current, and TX/RX optical power. Its compact design supports high-density 25Gbps optical connectivity in compatible network equipment.

Designed for 25GBASE-SR Ethernet applications, the transceiver complies with the stated SFF-8472, SFF-8402, SFF-8432, and SFF-8431 specifications. It operates over a case temperature range of 0 to +70C and is specified as RoHS compliant and lead-free.

Key Features & Engineering Advantages

25.78125Gbps Data Rate - Supports high-speed 25GBASE-SR Ethernet over multimode fiber.

850nm VCSEL & PIN Receiver - Provides short-range optical transmission with a duplex LC interface.

70m OM3 / 100m OM4 Reach - Supports multimode fiber links according to the selected cable grade.

Digital Diagnostic Monitoring (DDM) - Monitors temperature, supply voltage, TX bias current, and TX/RX optical power.

Hot-Pluggable SFP28 Design - Compact optical module with a single 3.3V power supply.

Commercial Temperature & Standards - Operates from 0 to +70C and complies with the stated SFF interface specifications.

Technical Specifications

General Specifications

Parameter Specification
Product Model D281-8M25-SCY1
Product Type 25G SFP28 SR Optical Transceiver
Data Rate Up to 25.7813Gbps
Ordering Data Rate 25.78125Gbps
Wavelength 850nm
Transmitter VCSEL Laser
Receiver PIN Photodetector
Fiber Type Multimode Fiber
OM3 Transmission Distance 70m
OM4 Transmission Distance 100m
Optical Interface Duplex LC
Form Factor Hot-Pluggable SFP28
Digital Diagnostics DDM / DDMI
Power Supply Single +3.3V
Operating Case Temperature 0 to +70C
Application 25GBASE-SR Ethernet
Standards Compliance SFF-8472, SFF-8402, SFF-8432, SFF-8431
Environmental Compliance RoHS Compliant, Lead-Free
Product Document Revision A1

Absolute Maximum Ratings

Parameter Symbol Min Typ Max Unit
Maximum Supply Voltage Vcc -0.5 - 3.6 V
Storage Temperature TS -40 - 85 C
Case Operating Temperature TOP 0 - 70 C
Relative Humidity RH 0 - 85 %

Note: Relative humidity is specified under non-condensing conditions.

Optical Characteristics

Test Conditions: TOP = 0 to 70C, Vcc = 3.3V +/-5%.

Transmitter

Parameter Symbol Min Typ Max Unit
Center Wavelength lambda c 840 850 860 nm
RMS Spectral Width Pm - - 0.6 nm
Average Output Power Pavg -8.4 - 2.4 dBm
Optical Modulation Amplitude Poma -6.4 - 3 dBm
Extinction Ratio ER 2 - - dB
Transmitter Dispersion Penalty TDEC - - 4.3 dB
Optical Return Loss Tolerance TOL 12 - - dB
Transmitter OFF Output Power POff - - -30 dBm

Transmitter Eye Mask

Parameter Value
Eye Mask Parameters X1, X2, X3, Y1, Y2, Y3
X1 0.3
X2 0.38
X3 0.45
Y1 0.35
Y2 0.41
Y3 0.5
Hit Ratio 1.5E-3

Receiver

Parameter Symbol Specified Value Unit Note
Center Wavelength lambda c 840 / 850 / 860 (Min / Typ / Max) nm -
Receiver Stressed Sensitivity, OMA - -5.2 dBm -
Receiver Sensitivity, Average Power - -10.3 dBm Note 1
Receiver Sensitivity, Average Power - -5.2 dBm Note 2
Receiver Reflectance Rfl -26 dBm Source unit
Loss of Signal Assert PA -30 dBm -
Loss of Signal Deassert PD -13 dBm -
LOS Hysteresis PD - PA 0.5 dB -

The values in the receiver table are retained from the original specification. The source's plain-text layout does not unambiguously preserve every Min/Typ/Max placement; therefore, the values are presented as specified values rather than assigning unsupported limits.

Optical Test Notes

BER = 5 x 10-5, PRBS 2^31-1 at 25.78195Gbps.

BER = 1 x 10-12, PRBS 2^31-1 at 25.78195Gbps.

The source uses 25.78195Gbps in the optical test notes and 25.78125Gbps in the ordering table. Both are retained pending engineering confirmation.

Electrical Characteristics

Test Conditions: TOP = 0 to 70C, Vcc = 3.3V +/-5%.

Parameter Symbol Min Typ Max Unit Note
Supply Voltage Vcc 3.135 3.3 3.465 V -
Supply Current Icc - - 300 mA -

Transmitter Electrical Characteristics

Parameter Symbol Min Typ Max Unit Note
Input Differential Impedance Rin - 100 - Ohm Note 1
Differential Data Input Swing Vin, pp 200 - 1000 mV -
Transmit Disable Voltage VD 2 - VCC V -
Transmit Enable Voltage VEN Vee - Vee+0.8 V -

Receiver Electrical Characteristics

Parameter Symbol Min Typ Max Unit Note
Differential Data Output Swing Vout, pp 200 - 1000 mV Note 2
LOS Fault VLOS_fault 2 - Vcc V Note 3
LOS Normal VLOS_norm Vee - Vee+0.8 V Note 3

Power Supply Noise Tolerance

Parameter Symbol Specification Unit
Power Supply Noise Tolerance VCCT / VCCR Per SFF-8431 Rev. 4.1 mVpp

Electrical Notes

The transmitter is connected directly to the TX data input pins. AC coupling is provided between the pins and laser driver IC.

Receiver output swing is measured into a 100 Ohm differential termination.

LOS measurements use a Module Compliance Test Board and OMA test pattern. A sequence of four 1s followed by four 0s in PRBS^9 is an acceptable alternative, according to the source reference to SFF-8431 Rev. 4.1.

Digital Diagnostic Monitoring

The 25G SFP28 SR optical transceiver supports digital diagnostic monitoring through the module management interface.

Parameter Unit Accuracy
Case Temperature C +/-3
Supply Voltage V +/-3%
TX Bias Current mA +/-10%
TX Optical Power dB +/-3
RX Optical Power dB +/-3

Digital Diagnostic Memory Map

The original specification includes a separate Digital Diagnostic Memory Map section. Its detailed address layout is contained in the original document graphic and has not been reproduced from the supplied text.

The approved memory map should be inserted here as the original technical diagram.

Pin Definitions

The module uses a 20-pin SFP28 host interface.

Pin Symbol Description Reference
1 VEET Transmitter Ground, Common with Receiver Ground 1
2 TFAULT Transmitter Fault 2
3 TDIS Transmitter Disable, Laser Disabled on HIGH or Open 3
4 SDA Two-Wire Serial Interface Data Line 4
5 SCL Two-Wire Serial Interface Clock Line 4
6 MOD_ABS Module Absent, Grounded Within Module 4
7 RS0 No Connection Required -
8 LOS Loss of Signal; Logic 0 Indicates Normal Operation 5
9 RS1 No Connection Required -
10 VEER Receiver Ground, Common with Transmitter Ground 1
11 VEER Receiver Ground, Common with Transmitter Ground 1
12 RD- Receiver Inverted Data Output, AC-Coupled -
13 RD+ Receiver Non-Inverted Data Output, AC-Coupled -
14 VEER Receiver Ground, Common with Transmitter Ground 1
15 VCCR Receiver Power Supply -
16 VCCT Transmitter Power Supply -
17 VEET Transmitter Ground, Common with Receiver Ground 1
18 TD+ Transmitter Non-Inverted Data Input, AC-Coupled -
19 TD- Transmitter Inverted Data Input, AC-Coupled -
20 VEET Transmitter Ground, Common with Receiver Ground 1

Pin Notes

Circuit ground is internally isolated from chassis ground.

TFAULT is an open-collector/open-drain output requiring a 4.7k-10k Ohm host pull-up resistor. The original note also refers to grounding inside an SFP+ cable plug; this wording requires confirmation for this optical module.

The transmitter laser is disabled when TDIS exceeds 2.0V or is left open. It is enabled when TDIS is below 0.8V.

SDA, SCL, and related module-definition lines require 4.7k-10k Ohm pull-up resistors to a host voltage between 2.0V and 3.6V, as applicable. MOD_ABS is pulled LOW to indicate that the module is installed.

LOS is an open-collector output requiring a 4.7k-10k Ohm host pull-up resistor to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.

Recommended Interface Circuit

The module provides differential electrical data connections, separate transmitter and receiver power pins, and a two-wire management interface.

The host design must follow the specified electrical input/output levels, 3.3V power supply requirements, and control signal pull-up configurations.

The original Recommended Interface Circuit diagram should be retained for hardware integration and PCB design review.

Mechanical Specifications

Parameter Specification
Module Form Factor SFP28
Mechanical Interface Hot-Pluggable
Optical Connector Duplex LC
Fiber Type Multimode
Host Interface SFP28
Mechanical Dimensions Refer to Original Drawing

The original specification includes a Mechanical Dimensions drawing. Exact dimensions and mechanical tolerances should be taken from the approved drawing.

Product Variants & Ordering Information

The D281-8M25-SCY1 is an 850nm 25G SFP28 SR optical transceiver designed for OM3 and OM4 multimode fiber.

Part Number Data Rate Wavelength Distance Fiber Type DDMI Connector Temperature
D281-8M25-SCY1 25.78125Gbps 850nm 70m OM3 / 100m OM4 MMF Yes Duplex LC 0 to +70C

OEM/ODM Requirements for Review

Host switch compatibility coding

EEPROM and module identification requirements

Private-label product identification

Product packaging customization

Project-specific qualification and testing requirements

Any nonstandard configuration must be confirmed before ordering.

25G SFP28 Transceiver Module Applications

The 25G SFP28 SR transceiver supports 25GBASE-SR Ethernet over OM3 and OM4 multimode fiber in compatible 25Gbps network equipment.

25GBASE-SR Ethernet: Short-range 25Gbps optical connections using OM3 or OM4 multimode fiber.

Data Center Switching: 25Gbps links between compatible switches and network equipment.

Server Connectivity: Short-range optical connections between compatible servers, network interface cards, and switches.

High-Density Network Cabling: Duplex LC interconnections within equipment rooms and data center infrastructure.

Typical Network Architecture

The 25G SFP28 SR transceiver uses two optical fibers for separate transmit and receive connections.

25G Server / Switch -> 25G SFP28 SR Module -> Duplex LC OM3/OM4 Patch Cord -> Multimode Fiber -> Remote 25G SFP28 SR Module -> 25G Switch / Server

Maximum specified distances:

OM3 Multimode Fiber: 70m

OM4 Multimode Fiber: 100m

The complete optical channel must remain within the specified performance limits.

Engineering Selection & Installation Guidelines

1. Select the Correct Multimode Fiber

Use OM3 or OM4 multimode fiber with compatible duplex LC connectors. The specified maximum reach is 70m on OM3 and 100m on OM4. Actual link performance depends on cable characteristics, connector losses, and installed channel conditions.

2. Verify Optical Power and Link Compatibility

The transmitter average output power range is -8.4 to +2.4 dBm. Receiver sensitivity is specified as -10.3 dBm under the source's BER = 5 x 10-5 test condition.

Before deployment, verify the complete optical channel against the relevant receiver sensitivity, OMA, and link performance requirements. Do not use the BER-dependent receiver sensitivity value as a guaranteed error-free optical budget.

3. Confirm Host Compatibility

Verify that the host supports a 25Gbps SFP28 interface, the required module management functions, and the specified 3.3V supply. Confirm EEPROM coding and equipment compatibility before purchasing modules for third-party switches.

4. Inspect and Clean Optical Interfaces

Clean and inspect LC connector end faces before installation. Maintain correct TX/RX polarity, avoid excessive fiber bending, and follow ESD-safe handling procedures when inserting or removing modules.

Frequently Asked Questions

1. What is a 25G SFP28 transceiver module?

A 25G SFP28 transceiver module is a hot-pluggable optical module designed for 25Gbps-class fiber connections. Spring Optical's 850nm SR model supports 25.78125Gbps transmission over OM3 or OM4 multimode fiber, with a duplex LC interface and digital diagnostic monitoring.

2. What is the difference between SFP28 SR and LR modules?

SFP28 SR modules are designed for short-range multimode fiber links, while LR modules generally use single-mode fiber for longer distances. This 850nm SR model supports 70m on OM3 and 100m on OM4. SR and LR modules must not be treated as interchangeable optical interfaces.

3. What is the maximum transmission distance?

The maximum specified transmission distance is 70m over OM3 multimode fiber and 100m over OM4 multimode fiber. Both limits are associated with the 850nm optical interface. Actual network channel performance must account for connector losses, cable characteristics, and the installed optical path.

4. Is this 25G SFP28 module compatible with Cisco or other switches?

Compatibility depends on the host equipment model, firmware, SFP28 electrical interface, and EEPROM requirements. The module lists compliance with SFF-8402, SFF-8431, SFF-8432, and SFF-8472. Vendor-specific acceptance should be verified using the intended switch or network interface before bulk procurement.

5. Does the module support DDM monitoring?

Yes. The module supports digital diagnostic monitoring for case temperature, supply voltage, transmitter bias current, transmitted optical power, and received optical power. Monitoring accuracy is specified in the technical table. The host must support the management interface to access the diagnostic information.

6. What are the operating temperature and power requirements?

The transceiver operates over a case temperature range of 0 to +70C with a nominal 3.3V power supply. The recommended supply voltage range is 3.135V to 3.465V, with a maximum specified supply current of 300mA. Industrial-temperature operation is not specified for this model.

Quality Assurance & OEM/ODM Manufacturing

Shenzhen Spring Optical Communication Co., Ltd. supplies optical communication components for telecom operators, data center integrators, equipment vendors, and distributors.

Spring Optical supports OEM/ODM coordination for optical transceiver procurement, product identification, host compatibility requirements, and customized packaging.

Relevant Product Verification

Optical wavelength and transmitter power measurement

Receiver sensitivity and optical performance evaluation

Eye mask and BER-related testing

Electrical interface and power supply verification

Digital diagnostic monitoring checks

Host equipment compatibility evaluation

Product appearance and connector inspection

The inspection scope and testing frequency should be confirmed through the applicable production quality records. The supplied source does not establish 100% testing coverage for every item listed above.

Packing, Storage & Shipping

The specified storage temperature range is -40 to +85C, with 0%-85% relative humidity under non-condensing conditions.

Protect the optical connector and electrical interface from contamination, physical damage, and electrostatic discharge. Appropriate protective packing should be confirmed before shipment.

Packing quantities, carton dimensions, delivery schedules, and shipping methods are determined according to the final order requirements.

Related Products

Product Application
25G SFP28 LR Transceiver Module Longer-distance 25Gbps single-mode optical links
10G SFP+ SR Transceiver Short-range 10Gbps multimode connections
100G QSFP28 SR4 Transceiver High-speed multimode connectivity for compatible 100Gbps equipment
OM3 Multimode Fiber Patch Cord Duplex LC connections up to the specified 70m reach
OM4 Multimode Fiber Patch Cord Duplex LC connections up to the specified 100m reach
LC Fiber Optic Patch Panel Structured fiber termination and cable management

Request Datasheet & Quotation

Contact Spring Optical for the 25G SFP28 SR optical transceiver datasheet, host compatibility verification, OEM/ODM requirements, sample evaluation, or project quotation.

Please provide the host switch model, required fiber type, link distance, quantity, and any specific compatibility coding requirements.

Hot Tags: SFP28 25G, 25G SFP28 Transceiver Module, Optical Transceiver, Transceiver Module, Optical Module, SFP28, SFP Transceiver, Fiber Transceiver, 25G SFP28 SR, 25G Optical Transceiver, 25GBASE-SR Transceiver,