Spring Optical Communication is one of the largest and best 25g sfp28 sr transceiver module 850nm multimode 100m duplex lc ddm manufacturers and suppliers with rich experience. Welcome to buy our high quality products or wholesale our customized 25g sfp28 sr transceiver module 850nm multimode 100m duplex lc ddm in stock with our factory. Also, free sample is also available if necessary.
The 25G SFP28 SR Transceiver Module is an 850nm multimode optical transceiver designed for 25.78125Gbps data transmission. Featuring a VCSEL laser, PIN receiver, duplex LC interface, and digital diagnostic monitoring (DDM), it supports 25GBASE-SR Ethernet links up to 70m over OM3 or 100m over OM4 multimode fiber.
Product Overview

Spring Optical's 25G SFP28 SR Transceiver Module supports 25.78125Gbps optical transmission over multimode fiber. The D281-8M25-SCY1 model uses an 850nm VCSEL laser transmitter, PIN photodetector, and duplex LC interface, supporting link distances of 70m on OM3 and 100m on OM4 fiber.
The optical module features a hot-pluggable SFP28 footprint, a single 3.3V power supply, and digital diagnostic monitoring for module temperature, supply voltage, laser bias current, and TX/RX optical power. Its compact design supports high-density 25Gbps optical connectivity in compatible network equipment.
Designed for 25GBASE-SR Ethernet applications, the transceiver complies with the stated SFF-8472, SFF-8402, SFF-8432, and SFF-8431 specifications. It operates over a case temperature range of 0 to +70C and is specified as RoHS compliant and lead-free.
Key Features & Engineering Advantages
25.78125Gbps Data Rate - Supports high-speed 25GBASE-SR Ethernet over multimode fiber.
850nm VCSEL & PIN Receiver - Provides short-range optical transmission with a duplex LC interface.
70m OM3 / 100m OM4 Reach - Supports multimode fiber links according to the selected cable grade.
Digital Diagnostic Monitoring (DDM) - Monitors temperature, supply voltage, TX bias current, and TX/RX optical power.
Hot-Pluggable SFP28 Design - Compact optical module with a single 3.3V power supply.
Commercial Temperature & Standards - Operates from 0 to +70C and complies with the stated SFF interface specifications.
Technical Specifications
General Specifications
| Parameter | Specification |
|---|---|
| Product Model | D281-8M25-SCY1 |
| Product Type | 25G SFP28 SR Optical Transceiver |
| Data Rate | Up to 25.7813Gbps |
| Ordering Data Rate | 25.78125Gbps |
| Wavelength | 850nm |
| Transmitter | VCSEL Laser |
| Receiver | PIN Photodetector |
| Fiber Type | Multimode Fiber |
| OM3 Transmission Distance | 70m |
| OM4 Transmission Distance | 100m |
| Optical Interface | Duplex LC |
| Form Factor | Hot-Pluggable SFP28 |
| Digital Diagnostics | DDM / DDMI |
| Power Supply | Single +3.3V |
| Operating Case Temperature | 0 to +70C |
| Application | 25GBASE-SR Ethernet |
| Standards Compliance | SFF-8472, SFF-8402, SFF-8432, SFF-8431 |
| Environmental Compliance | RoHS Compliant, Lead-Free |
| Product Document Revision | A1 |
Absolute Maximum Ratings
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Maximum Supply Voltage | Vcc | -0.5 | - | 3.6 | V |
| Storage Temperature | TS | -40 | - | 85 | C |
| Case Operating Temperature | TOP | 0 | - | 70 | C |
| Relative Humidity | RH | 0 | - | 85 | % |
Note: Relative humidity is specified under non-condensing conditions.
Optical Characteristics
Test Conditions: TOP = 0 to 70C, Vcc = 3.3V +/-5%.
Transmitter
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Center Wavelength | lambda c | 840 | 850 | 860 | nm |
| RMS Spectral Width | Pm | - | - | 0.6 | nm |
| Average Output Power | Pavg | -8.4 | - | 2.4 | dBm |
| Optical Modulation Amplitude | Poma | -6.4 | - | 3 | dBm |
| Extinction Ratio | ER | 2 | - | - | dB |
| Transmitter Dispersion Penalty | TDEC | - | - | 4.3 | dB |
| Optical Return Loss Tolerance | TOL | 12 | - | - | dB |
| Transmitter OFF Output Power | POff | - | - | -30 | dBm |
Transmitter Eye Mask
| Parameter | Value |
|---|---|
| Eye Mask Parameters | X1, X2, X3, Y1, Y2, Y3 |
| X1 | 0.3 |
| X2 | 0.38 |
| X3 | 0.45 |
| Y1 | 0.35 |
| Y2 | 0.41 |
| Y3 | 0.5 |
| Hit Ratio | 1.5E-3 |
Receiver
| Parameter | Symbol | Specified Value | Unit | Note |
|---|---|---|---|---|
| Center Wavelength | lambda c | 840 / 850 / 860 (Min / Typ / Max) | nm | - |
| Receiver Stressed Sensitivity, OMA | - | -5.2 | dBm | - |
| Receiver Sensitivity, Average Power | - | -10.3 | dBm | Note 1 |
| Receiver Sensitivity, Average Power | - | -5.2 | dBm | Note 2 |
| Receiver Reflectance | Rfl | -26 | dBm | Source unit |
| Loss of Signal Assert | PA | -30 | dBm | - |
| Loss of Signal Deassert | PD | -13 | dBm | - |
| LOS Hysteresis | PD - PA | 0.5 | dB | - |
The values in the receiver table are retained from the original specification. The source's plain-text layout does not unambiguously preserve every Min/Typ/Max placement; therefore, the values are presented as specified values rather than assigning unsupported limits.
Optical Test Notes
BER = 5 x 10-5, PRBS 2^31-1 at 25.78195Gbps.
BER = 1 x 10-12, PRBS 2^31-1 at 25.78195Gbps.
The source uses 25.78195Gbps in the optical test notes and 25.78125Gbps in the ordering table. Both are retained pending engineering confirmation.
Electrical Characteristics
Test Conditions: TOP = 0 to 70C, Vcc = 3.3V +/-5%.
| Parameter | Symbol | Min | Typ | Max | Unit | Note |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | 3.135 | 3.3 | 3.465 | V | - |
| Supply Current | Icc | - | - | 300 | mA | - |
Transmitter Electrical Characteristics
| Parameter | Symbol | Min | Typ | Max | Unit | Note |
|---|---|---|---|---|---|---|
| Input Differential Impedance | Rin | - | 100 | - | Ohm | Note 1 |
| Differential Data Input Swing | Vin, pp | 200 | - | 1000 | mV | - |
| Transmit Disable Voltage | VD | 2 | - | VCC | V | - |
| Transmit Enable Voltage | VEN | Vee | - | Vee+0.8 | V | - |
Receiver Electrical Characteristics
| Parameter | Symbol | Min | Typ | Max | Unit | Note |
|---|---|---|---|---|---|---|
| Differential Data Output Swing | Vout, pp | 200 | - | 1000 | mV | Note 2 |
| LOS Fault | VLOS_fault | 2 | - | Vcc | V | Note 3 |
| LOS Normal | VLOS_norm | Vee | - | Vee+0.8 | V | Note 3 |
Power Supply Noise Tolerance
| Parameter | Symbol | Specification | Unit |
|---|---|---|---|
| Power Supply Noise Tolerance | VCCT / VCCR | Per SFF-8431 Rev. 4.1 | mVpp |
Electrical Notes
The transmitter is connected directly to the TX data input pins. AC coupling is provided between the pins and laser driver IC.
Receiver output swing is measured into a 100 Ohm differential termination.
LOS measurements use a Module Compliance Test Board and OMA test pattern. A sequence of four 1s followed by four 0s in PRBS^9 is an acceptable alternative, according to the source reference to SFF-8431 Rev. 4.1.
Digital Diagnostic Monitoring
The 25G SFP28 SR optical transceiver supports digital diagnostic monitoring through the module management interface.
| Parameter | Unit | Accuracy |
|---|---|---|
| Case Temperature | C | +/-3 |
| Supply Voltage | V | +/-3% |
| TX Bias Current | mA | +/-10% |
| TX Optical Power | dB | +/-3 |
| RX Optical Power | dB | +/-3 |
Digital Diagnostic Memory Map
The original specification includes a separate Digital Diagnostic Memory Map section. Its detailed address layout is contained in the original document graphic and has not been reproduced from the supplied text.
The approved memory map should be inserted here as the original technical diagram.
Pin Definitions
The module uses a 20-pin SFP28 host interface.
| Pin | Symbol | Description | Reference |
|---|---|---|---|
| 1 | VEET | Transmitter Ground, Common with Receiver Ground | 1 |
| 2 | TFAULT | Transmitter Fault | 2 |
| 3 | TDIS | Transmitter Disable, Laser Disabled on HIGH or Open | 3 |
| 4 | SDA | Two-Wire Serial Interface Data Line | 4 |
| 5 | SCL | Two-Wire Serial Interface Clock Line | 4 |
| 6 | MOD_ABS | Module Absent, Grounded Within Module | 4 |
| 7 | RS0 | No Connection Required | - |
| 8 | LOS | Loss of Signal; Logic 0 Indicates Normal Operation | 5 |
| 9 | RS1 | No Connection Required | - |
| 10 | VEER | Receiver Ground, Common with Transmitter Ground | 1 |
| 11 | VEER | Receiver Ground, Common with Transmitter Ground | 1 |
| 12 | RD- | Receiver Inverted Data Output, AC-Coupled | - |
| 13 | RD+ | Receiver Non-Inverted Data Output, AC-Coupled | - |
| 14 | VEER | Receiver Ground, Common with Transmitter Ground | 1 |
| 15 | VCCR | Receiver Power Supply | - |
| 16 | VCCT | Transmitter Power Supply | - |
| 17 | VEET | Transmitter Ground, Common with Receiver Ground | 1 |
| 18 | TD+ | Transmitter Non-Inverted Data Input, AC-Coupled | - |
| 19 | TD- | Transmitter Inverted Data Input, AC-Coupled | - |
| 20 | VEET | Transmitter Ground, Common with Receiver Ground | 1 |
Pin Notes
Circuit ground is internally isolated from chassis ground.
TFAULT is an open-collector/open-drain output requiring a 4.7k-10k Ohm host pull-up resistor. The original note also refers to grounding inside an SFP+ cable plug; this wording requires confirmation for this optical module.
The transmitter laser is disabled when TDIS exceeds 2.0V or is left open. It is enabled when TDIS is below 0.8V.
SDA, SCL, and related module-definition lines require 4.7k-10k Ohm pull-up resistors to a host voltage between 2.0V and 3.6V, as applicable. MOD_ABS is pulled LOW to indicate that the module is installed.
LOS is an open-collector output requiring a 4.7k-10k Ohm host pull-up resistor to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
Recommended Interface Circuit
The module provides differential electrical data connections, separate transmitter and receiver power pins, and a two-wire management interface.
The host design must follow the specified electrical input/output levels, 3.3V power supply requirements, and control signal pull-up configurations.
The original Recommended Interface Circuit diagram should be retained for hardware integration and PCB design review.
Mechanical Specifications
| Parameter | Specification |
|---|---|
| Module Form Factor | SFP28 |
| Mechanical Interface | Hot-Pluggable |
| Optical Connector | Duplex LC |
| Fiber Type | Multimode |
| Host Interface | SFP28 |
| Mechanical Dimensions | Refer to Original Drawing |
The original specification includes a Mechanical Dimensions drawing. Exact dimensions and mechanical tolerances should be taken from the approved drawing.
Product Variants & Ordering Information
The D281-8M25-SCY1 is an 850nm 25G SFP28 SR optical transceiver designed for OM3 and OM4 multimode fiber.
| Part Number | Data Rate | Wavelength | Distance | Fiber Type | DDMI | Connector | Temperature |
|---|---|---|---|---|---|---|---|
| D281-8M25-SCY1 | 25.78125Gbps | 850nm | 70m OM3 / 100m OM4 | MMF | Yes | Duplex LC | 0 to +70C |
OEM/ODM Requirements for Review
Host switch compatibility coding
EEPROM and module identification requirements
Private-label product identification
Product packaging customization
Project-specific qualification and testing requirements
Any nonstandard configuration must be confirmed before ordering.
25G SFP28 Transceiver Module Applications
The 25G SFP28 SR transceiver supports 25GBASE-SR Ethernet over OM3 and OM4 multimode fiber in compatible 25Gbps network equipment.
25GBASE-SR Ethernet: Short-range 25Gbps optical connections using OM3 or OM4 multimode fiber.
Data Center Switching: 25Gbps links between compatible switches and network equipment.
Server Connectivity: Short-range optical connections between compatible servers, network interface cards, and switches.
High-Density Network Cabling: Duplex LC interconnections within equipment rooms and data center infrastructure.
Typical Network Architecture
The 25G SFP28 SR transceiver uses two optical fibers for separate transmit and receive connections.
25G Server / Switch -> 25G SFP28 SR Module -> Duplex LC OM3/OM4 Patch Cord -> Multimode Fiber -> Remote 25G SFP28 SR Module -> 25G Switch / Server
Maximum specified distances:
OM3 Multimode Fiber: 70m
OM4 Multimode Fiber: 100m
The complete optical channel must remain within the specified performance limits.
Engineering Selection & Installation Guidelines
1. Select the Correct Multimode Fiber
Use OM3 or OM4 multimode fiber with compatible duplex LC connectors. The specified maximum reach is 70m on OM3 and 100m on OM4. Actual link performance depends on cable characteristics, connector losses, and installed channel conditions.
2. Verify Optical Power and Link Compatibility
The transmitter average output power range is -8.4 to +2.4 dBm. Receiver sensitivity is specified as -10.3 dBm under the source's BER = 5 x 10-5 test condition.
Before deployment, verify the complete optical channel against the relevant receiver sensitivity, OMA, and link performance requirements. Do not use the BER-dependent receiver sensitivity value as a guaranteed error-free optical budget.
3. Confirm Host Compatibility
Verify that the host supports a 25Gbps SFP28 interface, the required module management functions, and the specified 3.3V supply. Confirm EEPROM coding and equipment compatibility before purchasing modules for third-party switches.
4. Inspect and Clean Optical Interfaces
Clean and inspect LC connector end faces before installation. Maintain correct TX/RX polarity, avoid excessive fiber bending, and follow ESD-safe handling procedures when inserting or removing modules.
Frequently Asked Questions
1. What is a 25G SFP28 transceiver module?
A 25G SFP28 transceiver module is a hot-pluggable optical module designed for 25Gbps-class fiber connections. Spring Optical's 850nm SR model supports 25.78125Gbps transmission over OM3 or OM4 multimode fiber, with a duplex LC interface and digital diagnostic monitoring.
2. What is the difference between SFP28 SR and LR modules?
SFP28 SR modules are designed for short-range multimode fiber links, while LR modules generally use single-mode fiber for longer distances. This 850nm SR model supports 70m on OM3 and 100m on OM4. SR and LR modules must not be treated as interchangeable optical interfaces.
3. What is the maximum transmission distance?
The maximum specified transmission distance is 70m over OM3 multimode fiber and 100m over OM4 multimode fiber. Both limits are associated with the 850nm optical interface. Actual network channel performance must account for connector losses, cable characteristics, and the installed optical path.
4. Is this 25G SFP28 module compatible with Cisco or other switches?
Compatibility depends on the host equipment model, firmware, SFP28 electrical interface, and EEPROM requirements. The module lists compliance with SFF-8402, SFF-8431, SFF-8432, and SFF-8472. Vendor-specific acceptance should be verified using the intended switch or network interface before bulk procurement.
5. Does the module support DDM monitoring?
Yes. The module supports digital diagnostic monitoring for case temperature, supply voltage, transmitter bias current, transmitted optical power, and received optical power. Monitoring accuracy is specified in the technical table. The host must support the management interface to access the diagnostic information.
6. What are the operating temperature and power requirements?
The transceiver operates over a case temperature range of 0 to +70C with a nominal 3.3V power supply. The recommended supply voltage range is 3.135V to 3.465V, with a maximum specified supply current of 300mA. Industrial-temperature operation is not specified for this model.
Quality Assurance & OEM/ODM Manufacturing
Shenzhen Spring Optical Communication Co., Ltd. supplies optical communication components for telecom operators, data center integrators, equipment vendors, and distributors.
Spring Optical supports OEM/ODM coordination for optical transceiver procurement, product identification, host compatibility requirements, and customized packaging.
Relevant Product Verification
Optical wavelength and transmitter power measurement
Receiver sensitivity and optical performance evaluation
Eye mask and BER-related testing
Electrical interface and power supply verification
Digital diagnostic monitoring checks
Host equipment compatibility evaluation
Product appearance and connector inspection
The inspection scope and testing frequency should be confirmed through the applicable production quality records. The supplied source does not establish 100% testing coverage for every item listed above.
Packing, Storage & Shipping
The specified storage temperature range is -40 to +85C, with 0%-85% relative humidity under non-condensing conditions.
Protect the optical connector and electrical interface from contamination, physical damage, and electrostatic discharge. Appropriate protective packing should be confirmed before shipment.
Packing quantities, carton dimensions, delivery schedules, and shipping methods are determined according to the final order requirements.
Related Products
| Product | Application |
|---|---|
| 25G SFP28 LR Transceiver Module | Longer-distance 25Gbps single-mode optical links |
| 10G SFP+ SR Transceiver | Short-range 10Gbps multimode connections |
| 100G QSFP28 SR4 Transceiver | High-speed multimode connectivity for compatible 100Gbps equipment |
| OM3 Multimode Fiber Patch Cord | Duplex LC connections up to the specified 70m reach |
| OM4 Multimode Fiber Patch Cord | Duplex LC connections up to the specified 100m reach |
| LC Fiber Optic Patch Panel | Structured fiber termination and cable management |
Request Datasheet & Quotation
Contact Spring Optical for the 25G SFP28 SR optical transceiver datasheet, host compatibility verification, OEM/ODM requirements, sample evaluation, or project quotation.
Please provide the host switch model, required fiber type, link distance, quantity, and any specific compatibility coding requirements.
Hot Tags: SFP28 25G, 25G SFP28 Transceiver Module, Optical Transceiver, Transceiver Module, Optical Module, SFP28, SFP Transceiver, Fiber Transceiver, 25G SFP28 SR, 25G Optical Transceiver, 25GBASE-SR Transceiver,